• Title/Summary/Keyword: coefficient of variation of diameter

Search Result 120, Processing Time 0.026 seconds

Fleece Phenotype Influences Susceptibility to Cortisol-induced Follicle Shutdown in Merino Sheep

  • Ansari-Renani, H.R.;Hynd, P.I.;Aghajanzadeh, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1761-1769
    • /
    • 2007
  • This experiment was conducted to determine the extent to which susceptibility to cortisol-induced follicle shutdown is influenced by fleece phentotype. Twenty Finewool (10 sheep low fibre diameter, low coefficient of fibre diameter-LL and 10 low fibre diameter, high coefficient of variation of fibre diameter-LH) and twenty Strongwool (10 low fibre diameter, low coefficient of variation of fibre diameter-HL and 10 high fibre diameter and high coefficient of variation of fibre diameter-HH) sheep of 9 months of age were individually penned in an animal house and were injected intramuscularly with an aqueous suspension of hydrocortisone acetate at a rate of 1.42 mg/kg body weight for a period of two weeks. Fibre diameter was measured from clipped tattooed patch wool samples. Follicle activity was measured by histological changes in skin biopsies taken weekly. Blood samples were collected at two-week intervals and plasma cortisol measured. Increased plasma cortisol concentration significantly (p<0.05) reduced clean wool production and mean fibre diameter dropped to its lowest level four weeks after commencement and two weeks after the cessation of cortisol injection. Elevation of plasma cortisol concentration significantly (p<0.0001) increased the percentage of inactive follicles two weeks after injection started. High fibre diameter groups (Strongwool sheep; i.e. HL+HH) had significantly (p<0.0001) higher percentage of follicle shutdown than low fibre diameter groups (Finewool sheep; i.e. LL+LH). Average percentage of shutdown follicles for Finewool (LL+LH) and Strongwool (HL+HH) Merino sheep was $9.8{\pm}0.9$ and $13.5{\pm}0.9$ respectively. Shutdown of primary follicles was more pronounced in Finewool than Strongwool sheep. There was no significant effect of coefficient of variation of fibre diameter on propensity to follicle shutdown induced by exogenous cortisol. It is concluded that elevation in plasma cortisol concentration is inhibitory to the normal activity of follicles in Strongwool sheep but that variation in fibre diameter has little or no effect.

Genitic Variability and Correlation of Quantitative Characters in Local Garlic Cultivars (在來種마늘의 量的形質에 대한 遺傳變異와 相關)

  • 김정선
    • Korean Journal of Plant Resources
    • /
    • v.11 no.3
    • /
    • pp.264-271
    • /
    • 1998
  • This study was conducted to investigate morphological characteristics of Korean local garlic varieties and to define the genetic variability and the correlations amongthe characters associated with yield. The plant height, the leaf sheath diameter, the nubmer of leaves, and bulb weight were significantly increased in the garlic plants from heavier seed bulbs. The proportation of six clove bulbs was more than 60% in Seosan variety and this was not realted with the number of cloves in seed bulb. While more than 70% bulbs in Jeoksung and Danyang varieties cultivated in paddy field were composed of 6 or 7 cloves, majority of the bulbs of Euisung and Danyang varieties cultivated in upland were composed of bulbs with 7 cloves or more. The highest genotypic coefficient of variation (GCV) and phenotypic coefficient of variation (PCV) were observed in bulb weight. GCV and PCV also showed high value in leaf sheath diameter. Thus, there is a greater scope for selection of these characters. The small difference between PCV and GCV values in plant height indicates that the environmental influence would be limited in this character. High heritability was observed of plant height (56.76%) and bulb weight (45.95%). And the weight per bulb (34.24%) exhibited highest genitic advance followed by leaf sheath diameter (18.8%) and plant height (9.61%), and those would be the ideal characters for selelction.

  • PDF

Predicting Flow Resistance Coefficients in Water Supply Mains (주변환경을 고려한 상수관망의 관 마찰손실계수 산정)

  • 손광익
    • Water for future
    • /
    • v.29 no.4
    • /
    • pp.223-231
    • /
    • 1996
  • For the most efficient operation of water mains, 124 head losses in domestic water supply steel mains were measured to provide the values of friction coefficient and the variable affecting the deterioration rate of Hazen Williams' and Darcy-Weisbach's friction coefficient. The experimental results show that pipe age is governing the friction coefficient of large mains (Diameter > 1100 mm). On the other hands, pipe age and pipe diameter are affecting the variation of carrying capacity for small mains (Diameter < 1100 mm). The friction coefficient of water mains in foreign countries is higher than that in Korea by about 5 to 10 in Hazen Williams' C value. The growing rate of roughness height of domestic water main is about 0.41 mm/year which is higher than the average of United States of America. So further study is required to find out what causes the serious deterioration rate.

  • PDF

Effect of Design Factors in a Pump Station on Pressure Variations by Water Hammering (가압 펌프장에서 설계인자들이 수격에 의한 압력변동에 미치는 영향)

  • Park, Jong-Hoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.15-27
    • /
    • 2021
  • In this study, the effect of design factors in a pump station on the pressure variations which are the main cause of water hammering has been investigated by numerical simulations. As design factors, the flow rate, Young's modulus, diameter, thickness, roughness coefficient of pipeline are considered. The relationships between the pressure variations and the design factors are analyzed. The results show that the pressure variation increases sensitively with the flow rate and Young's modulus, and increases gradually with the thickness and roughness coefficient of pipe, whereas it decreases with the pipe diameter. The wavelength of the pressure wave becomes longer for a smaller Young's modulus, a smaller pipe thickness and a bigger pipe diameter. These relationships are nondimensionalized, and logarithmic curve-fitted functions are proposed by regression analysis. Most effective factors on the nondimensional pressure variation is Young's modulus. Flow rate, roughness coefficient, relative thickness and pipe diameters are the next impact factors.

Modelling Stem Diameter Variability in Pinus caribaea (Morelet) Plantations in South West Nigeria

  • Adesoye, Peter Oluremi
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.3
    • /
    • pp.280-290
    • /
    • 2016
  • Stem diameter variability is an essential inventory result that provides useful information in forest management decisions. Little has been done to explore the modelling potentials of standard deviation (SDD) and coefficient of variation (CVD) of diameter at breast height (dbh). This study, therefore, was aimed at developing and testing models for predicting SDD and CVD in stands of Pinus caribaea Morelet (pine) in south west Nigeria. Sixty temporary sample plots of size $20m{\times}20m$, ranging between 15 and 37 years were sampled, covering the entire range of pine in south west Nigeria. The dbh (cm), total and merchantable heights (m), number of stems and age of trees were measured within each plot. Basal area ($m^2$), site index (m), relative spacing and percentile positions of dbh at $24^{th}$, $63^{rd}$, $76^{th}$ and $93^{rd}$ (i.e. $P_{24}$, $P_{63}$, $P_{76}$ and $P_{93}$) were computed from measured variables for each plot. Linear mixed model (LMM) was used to test the effects of locations (fixed) and plots (random). Six candidate models (3 for SDD and 3 for CVD), using three categories of explanatory variables (i.e. (i) only stand size measures, (ii) distribution measures, and (iii) combination of i and ii). The best model was chosen based on smaller relative standard error (RSE), prediction residual sum of squares (PRESS), corrected Akaike Information Criterion ($AIC_c$) and larger coefficient of determination ($R^2$). The results of the LMM indicated that location and plot effects were not significant. The CVD and SDD models having only measures of percentiles (i.e. $P_{24}$ and $P_{93}$) as predictors produced better predictions than others. However, CVD model produced the overall best predictions, because of the lower RSE and stability in measuring variability across different stand developments. The results demonstrate the potentials of CVD in modelling stem diameter variability in relationship with percentiles variables.

Experimental Study on Coefficient of Flow Convection (유수대류계수에 관한 실험적 연구)

  • 정상은;오태근;양주경;김진근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.297-302
    • /
    • 2000
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structure, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection is developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect in internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. finally a prediction model of the coefficient of flow convection is proposed using experimental results from the developed device. According to the proposed prediction model, the coefficient of flow convection increases with increase in flow velocity and decreases with increase in pipe diameter and thickness. Also, the coefficient of flow convection is largely affected by the type of pipe materials.

  • PDF

Mass Transfer Characteristics in Pressurized Three-phase Slurry Bubble Columns with Variation of Column Diameter (가압 삼상슬러리 기포탑에서 직경변화에 따른 기체-액체 물질전달 특성)

  • Seo, Myung Jae;Lim, Dae Ho;Shin, Ik Sang;Son, Sung Mo;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.459-464
    • /
    • 2009
  • Gas-liquid mass transfer characteristics were investigated in pressurized three-phase slurry bubble columns with variation of column diameter. Effects of gas velocity, operating pressure, liquid viscosity, solid content in the slurry phase and column diameter on the gas-liquid volumetric mass transfer coefficient($k_La$) were determined. The effects of operating variables on the mass transfer coefficient tended to change with variation of column diameter. The mass transfer coefficient increased with increasing gas velocity or operating pressure but decreased with increasing column diameter, liquid viscosity or solid concentration in the slurry phase. The increase trend of $k_La$ value with increasing gas velocity and the decrease trend of $k_La$ value with increasing liquid viscosity, tended to decrease gradually with increasing column diameter. However, the effects of operating pressure and solid concentration in the slurry phase on the $k_La$ value did not change considerably with variation of column diameter. The values of $k_La$ were well correlated with operating variables with in this experimental conditions as $k_La=0.02D^{-0.26}U_G^{0.28}P^{0.43}{\mu}_L^{-0.04}S_c^{-0.35}$.

Analysis of Process Characteristics by Single Yarn Production in Ring Spinning (링 정방공정에서 단사제조에 의한 공정특성 분석)

  • Lee, Choon-Gil;Oh, Bong-Hyo;Park, Sung-Diuk
    • Textile Coloration and Finishing
    • /
    • v.9 no.5
    • /
    • pp.1-9
    • /
    • 1997
  • In the single yarn spinning process by the ring spinning system, the finer the fineness of yarn and the lower the twist coefficient, the lower the breaking strength and breaking elongation. The change of yarn specific volume to yarn number agreed with Peirce's formula in the range of Ne 50 to 70, but above that range the values of the experiment are higher than that of the formula. The change of diameter of yarn to the reciprocal of the square root of yarn number agreed with Peirce's formula in the range of under 0.14, but above that value the values of the experiment are higher than that of the formula. In breaking strength variation according to twist constant of single yarn, as the twist coefficient increased, breaking strength increased. At 5.8∼6.0 of twist coefficient the maximum breaking strength was shown, but above that value breaking strength decreased. Breaking elongation also showed a similar tendency. But at 6.0∼6.5 of twist coefficient the maximum breaking elongation was shown. Also spinning tension increased as twist coefficient increased. Twist coefficient, breaking strength and breaking elongation according to the number of coils stayed almost the same. Yarn spinning tension according to the number of coils at the maximum of diameter was the lowest value. The speed of the traveller at the maximum of diameter was the highest value.

  • PDF

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.

Effects of the Blockage Ratio of a Valve Disk on Loss Coefficient in a Butterfly Valve (밸브 디스크 차단비 변화가 버터플라이밸브의 손실계수에 미치는 영향에 관한 실험적 연구)

  • Rho, Byung-Joon;Choi, Hee-Joo;Lee, Jee-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.1
    • /
    • pp.39-46
    • /
    • 2008
  • The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.