• 제목/요약/키워드: coaxial

검색결과 1,000건 처리시간 0.026초

Toward Efficacy Improvement in a PDP Discharge Cell from Structural Considerations

  • Tachibana, Kunihide
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.20-23
    • /
    • 2009
  • The efficacy improvement issues in a unit discharge cell have been approached from the structural considerations. The tested cell designs include (a) a coplanar type with annular auxiliary electrode buried in barrier ribs, (b) a coplanar type with split auxiliary electrodes also burred in barrier ribs and (c) a coaxial type with a floating electrode stacked on the base electrode. From spatiotemporally resolved optical images of near-IR emission taken by a gated-ICCD camera and relative VUV emission intensity estimated by laser absorption spectroscopy, the differences in the discharge and light emission performances of those three cell types have been compared and discussed.

  • PDF

3차원 경계적분방정식법을 이용한 정전장 해석 (Electric Field Analysis Using Three Dimensional Boundary Integral Equation Method)

  • 김재홍;김동훈;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.828-830
    • /
    • 2000
  • This paper describes BIEM(Boundary Integral Equation Method) for computation of three dimensional electric field distribution and numerical method that an equivalent charge density is unknown variable. After computing numerically the surface charge distribution. the distribution of both potential and electric field are obtained. Finally, this numerical method is applied to the concentric sphere and the coaxial cylindrical model and numerical result is compared to the analytic solution.

  • PDF

MEASUREMENT OF R, L, C CHIP DEVICES USING COAXIAL PROBE

  • Kim, Y. H.;E. C. Noh;K. H. Shin;J. Y. Seo
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.212-213
    • /
    • 2002
  • 전자기기의 소형화에 동반하여 동작주파수가 높아짐에 따라 여기에 이용되는 소자의 크기도 밀리 사이즈에서 마이크로 사이즈까지 작아지고 있다. 이에 따라 여기에 이용되는 각종 소자의 전기적인 값도 작아지고 있으며 허용 오차 값이 적은 정밀한 소자가 이용되고 있다. 그러나 소자의 크기와 소자값의 감소에 따라 정확하고 간편하게 그리고 많은 소자를 효율적으로 측정할 수 있는 방법이 필요하다. 특성 임피던스 50 $\Omega$을 가지는 동축선로형 프루브 제작에 대해 이미 검토하였다[1]. (중략)

  • PDF

GIS가스 챔버내의 파티클에 의한 신호 분석 (Analysis of Signal by particles in GIS Chamger)

  • 조국희;이강수;이재걸;조용우;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.60-62
    • /
    • 1997
  • In this paper, the vibration & ultrasonic singals, \ulcorner 새 the collisions of particles in coaxial exectrodes are analyzed and discribed. These singals were detected and measured using ultrasonic and vibration sensors attached on the GIS enclosure. The relationship between the magnitude of the measured signal and the diameter and leght of the particle was analyzed.

  • PDF

배전자동화시스템의 정보통신 설계로 구현 사례 (The Distribution Automation System - its communication techniques)

  • 김명수;고상천;이상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3015-3017
    • /
    • 1999
  • KEPCO is faced with a number of network choice for Distribution Automation System(DAS), such as Power Line, Pair. Coaxial and Optical Cable, etc. The increasing use of DAS requires suitable communication networks. KEPCO has exhausted much efforts to implement its own standard DAS in possible early date. This paper presents the DAS in KEPCO and some of initial design efforts toward KEPCO's DAS at KEPRI.

  • PDF

동축 초음속 제트유동에 관한 기초적 연구 (A Fundamental Study of Coaxial Supersonic Jets)

  • 이권희;구병수;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2000년도 제15회 학술강연회논문초록집
    • /
    • pp.37-37
    • /
    • 2000
  • 일반적으로 노즐 입구의 압력과 배압의 비가 어떤 임계값보다 큰 경우에 축소확대 노즐을 통하는 유동은 노즐목에서 초크하며, 노즐출구에서는 용이하게 초음속으로 된다. 노즐을 통하여 초음속으로 방출되는 제트유동에 관해서는 현재까지 많은 연구가 수행되었다. 이들 연구에 의하면 노즐 압력 비에 따라 노즐출구에서의 유동상태(즉 과팽창, 적정팽창, 부족팽창상태)가 결정되며, 노즐출구로부터 하류의 초음속 제트유동에서 발생하는 충격파 구조 및 위치, 제트경계의 구조 그리고 제트의 코어 등 유동의 기구가 비교적 상세하게 알려져 있다.(중략)

  • PDF

Experimental study on the spray characteristics of a dual-manifold liquid-centered swirl coaxial injector

  • Lee, Ingyu;Yoon, Jungsoo;Park, Gujeong;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제15권4호
    • /
    • pp.444-453
    • /
    • 2014
  • A throttleable rocket engine enables operational possibilities such as the docking of spacecraft, maneuvering in a certain orbit and landing on a planet's surface, altitude control, and entrance to atmosphere-less planets. Thus, throttling methods have long been researched. However, dual-manifold injectors, which represent one throttling method, have been investigated less than others. In this study, dual-manifold and single-manifold injectors were compared to determine the characteristics of dual-manifold injectors. Also, the effects of gas injection were investigated with various F/O ratios. To investigate the characteristics, mass flow rate, spray pattern, spray angle, and droplet size were measured. The spray angle and droplet size were captured by indirect photography. About 30 images were taken to assess the spray patterns and spray angle. Also, 700 images were analyzed to understand the droplet distribution and targeting area, moving to the right from the centerline with 1.11-cm intervals. The droplet size was obtained from an image processing procedure. From the results, the spray angle showed two transition regions, due to swirl momentum in the swirl chamber regardless of the F/O ratio. The droplet size showed similar trends in both dual-manifold and single-manifold injectors except in the low mass flow rate region. In the case of the dual- manifold injector, the spray cone was not fully developed in the low mass flow rate region due to low angular momentum in the swirl chamber.

Syngas-순산소 확산화염의 연소특성에 관한 실험적 연구 (Experimental Study on the Combustion Characteristics of Syngas-Oxyfuel Diffusion Flames)

  • 이상민;최원석;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.553-560
    • /
    • 2010
  • The characteristics of syngas-oxyfuel combustion has been investigated experimentally in the present study. Experimental measurements were conducted to aid a fundamental design of a syngas-oxyfuel combustor with a double coaxial burner configuration. To examine the effects of different syngas fuels on combustion characteristics, various fuel types are utilized such as commercial coal gases (Texaco, Shell), COG (cokes oven gas), and $CH_4$ as a main component of natural gas. $CO_2$ was added to the four fuel types as a diluent gas to reduce the flame temperature. The flame images and emission characteristics of NOx and CO were examined for various equivalence ratio and $CO_2$ dilution ratio. The results show that CO emission was rapidly increased as equivalence ratio approached the stoichiometry condition by reducing the amount of oxygen. As the $CO_2$ dilution increased, CO emission increased while NOx emission decreased due to reduced flame temperature. When the syngas-oxyfuel combustor is operated with 20~40% of $CO_2$ dilution ratio, the CO and NOx emission levels were kept below 50 ppm and 25 ppm, respectively, with a high concentration of $CO_2$ over 95 vol.% in exhaust gases.

이중동축 메탄/공기 층류 부분 예혼합화염에서의 화염구조와 자발광 배출 특성;안쪽관 연료주입의 영향 (Flame Structure and Light Emission Characteristics in Coaxial Laminar Partially Premixed $CH_{4}/Air$ Flames;Effect of Central Fuel Injection)

  • 오정석;정용기;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1116-1121
    • /
    • 2004
  • In this study, the effect of central fuel injection on a coaxial laminar $CH_{4}/air$ flame was experimented at the defined premixing condition(${\Phi}=1.90$, ${\sigma}=50/75/100%$, x/D=10). The partial premixing parameter are the equivalence ratio that total fuel is fixed at 200cc/min, the fuel split degree which means the percentage of fuel entering the outer tube to the total amount, and the mixing distance indicating the nonreactant mixture's homogeneity between inner tube top and burner exit. The object is to investigate the flame structure and chemiluminescence characteristics of laminar partial premixed flame as changing mixing parameters. The radical signal was acquired from ICCD camera and PMT. Each intensity was compared with Abel inverted value for measuring the effect of background light on the peak signal location and the intensity at central preheat zone. The results show that the peak location of each radical was broaden as the fuel split degree increasing because the mixing quality was enhanced. and $OH^{\ast}$ is a good indicator for flame front between reaction and preheat zone. At last $CH_{2}^{\ast}$ has the same tendency with $CH^{\ast}$ but a thinner reaction zone than $CH^{\ast}$ due to a rapid decay on the burned gas side.

  • PDF