• Title/Summary/Keyword: coating properties

Search Result 2,855, Processing Time 0.031 seconds

Influence of the Dental Implant Abutment Screw Coating Materials on Joint Stability (임플란트 지대주나사 코팅이 결합안정성에 미치는 영향)

  • Lim, Hyun-Pil;Park, Young-Sun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yoon, Suk-ja
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.157-169
    • /
    • 2009
  • The aim of this study was to evaluate effect of implant abutment screw coating treatment on joint stability, investigating mechanical properties of these. For this study used $ExFeel^{(R)}$ external hexed implant system and $15mm{\times}1mm$ discs. Experimental group was $1{\mu}m$ TiN, TiCN, TiC coated abutment screws and discs. To know mechanical property, i evaluated adhesion strength, surface hardness, using disc, corrosion test using screw. The results were as follows : rotation angle of coated screws increased than that of non-coated screw because of lower friction coefficient, especially TiC coated screw group had the largest value, but removal torque decreased in all coated screws (p<0.05). Torque loss before and after fatigue test was the smallest in TiC-coated screws, and the largest in non-coated screws (p<0.05), and there was no statistically significant difference between dry condition and wet condition of screws because of higher surface hardness and lower friction coefficient. From the above results, TiN, TiCN, TiC coating group had high abrasion resistance, especially TiC coated group which had low torque-consuming, high rotation angle as low friction coefficient will be considered to influence on implant abutment screw joint stability positively.

Studies of Physicochemical Properties of Baby Powder Developed from Rice-flour (쌀 분말을 이용한 유아용 파우더의 이화학적 특성 연구)

  • Han, Sang-Ik;Jang, Ki Chang;Seo, Woo Duck;Oh, Seong-Hwan;Ra, Ji-Eun;Song, Yu-Cheon;Lee, Jong-Hee;Kim, Byung-Joo;Nam, Min-Hee;Lee, Jin-Tae
    • Journal of Life Science
    • /
    • v.23 no.7
    • /
    • pp.879-885
    • /
    • 2013
  • Baby powder is an astringent powder used to prevent diaper rash. It also has other cosmetic uses. In general, it is composed of talc powder (talcum powder). Talc powder is harmful if inhaled because it can cause significant lung damage. With the aim of developing a new rice-based baby powder, three kinds of rice varieties were selected and pulverized. To determine the cost-effectiveness of the different states of rice powder, several milling processes were tried, and the powder characteristics of the resulting rice powder, such as particle size, biological activities, digitalized color value, and moisture content before and after coating treatment with essential oil and silicon oil, were examined. "Goami" showed good flour characteristics with respect to lightness (92.0, $L^*$[D65] value) and particle size ($8.9{\mu}m$). SEM analysis showed that the rice powder particles coated in the essential oil and silicon oil showed a smoother and rounder appearance than those of the talc powder. In addition, the average particle size was decreased by the essential oil and silicon oil coating. The silicon oil coating solved the problem of moisture absorption in rice flour. Rice flour properly coated with essential oil and silicon oil shows great potential as a new material source of powder.

A Study on the Method for the Local Transmittance Measurements of the Ocular Lens (안경 렌즈의 국소적 투과율 측정을 위한 방법에 관한 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Youk, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • Purpose: We have analyzed the transmittance distribution of the ocular lens using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The transmittance of the laser which is focused on the surface of the ocular lens was measured by using the photo-detector and lock-in amplifier and analyzed. Multi-coated, uncoated, and progressive lenses were analyzed. Results: In the measurement of the progressive lens and a physical stimulated lens, local transmittance microscopy analysis showed a high degree of match with the measurement results through the optical microscope. In addition, the average value of the transmittance is reduced and the standard deviation was increased in the presence of optical defects. In unstimulated lens, there are a large impact on transmittance whether the anti-reflective coating is presence or absence in both the local transmittance microscopy and general transmittance analysis. Conclusions: The distribution of the transmittance measured by local transmission microscopy were changed when the various stimulus is applied to the lenses. These analyzes by local transmission microscopy can be utilized as a way to evaluate or determine the uniformity of the coating film or lens.

Design and deposition of two-layer antireflection and antistatic coatings using a TiN thin film (TiN 박막을 이용한 2층 무반사 코팅의 설계 및 층착)

  • 황보창권
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.323-329
    • /
    • 2000
  • In this study we have calculated an ideal complex refractive index of a TiN trim used in a layer of anl1reilecnon (I\R) coatmg, [air$ISiO_2ITiNIglass$] in the visible. Also we simulated the rellectance of lwo-layer AR coating by varying the thicknesses of TiN and $SiO_2$ layers, respecl1vely. The simolation results show that we can controllhe lowest reflectance and AR band of tile AR coating. The TIN fihns were fabricated by a RF magnetron sputtering apparalus. The chemical, structural and electrical properties of TiN fih11S were inveshgated by the Rutherford backscattering spech'oscopy (RBS), atomic force microscope (AFM) and 4-point probe. The optical properlies were inve,tigated by the spectrophotometer and vanable angle spectroscopic ellipsometer (VASE). The smface roughness of TiN flhns \vas $9~10\AA$. TIle resistivity of TiN films was TEX>$360~730\mu$\Omega $ cm. The ,toichlOllletry of TiN film was 1'1: O:N = I: 0.65 :0.95 and ilic oxygen wa~ found on ilie smface. With these experimental and simu]al1on resulLs, we deposited duo: two-layer AR coating, [air$ISiO_2ITiNIglass$] and the refleClance was under 0.5% ill the regIOn of 440-650 run. 0 run.

  • PDF

Evaluation of the Removal Properties of Mn(II) by Manganese-Coated Sand (망간사에 의한 망간제거 특성 평가)

  • Yu, Mok-Ryun;Yang, Jae-Kyu;Kim, Mu-Nui;Lee, Seung-Mok;Lee, Nam-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.571-576
    • /
    • 2007
  • Manganese-Coated Sand(MCS) prepared with three different methods were applied in the treatment of soluble $Mn^{2+}$ in batch and column experiments. In the bench-scale MCS preparation, the coating efficiency of manganese on the surface of sand increased as the dosage of initial Mn(II) increased. The removed amount of the soluble $Mn^{2+}$ by MCS increased as the solution pH increased, following a typical anionic-type adsorption. The removed amounts of the soluble $Mn^{2+}$ through adsorption was quite similar over the entire pH range, without depending on the contents of Mn on the surface of sand as well as coating methods. When NaClO was used an oxidant, the removed amount of the soluble $Mn^{2+}$ by MCS increased as the concentration of NaClO increased, This trend might be explained by the increased removal efficiency through coating of manganese oxides produced from oxidation of the soluble $Mn^{2+}$ by NaClO on the surface of MCS. From the bench-scale column experiments, the breakthrough of $Mn^{2+}$ occurred after 4,100 bed volume without presence of NaClO while 1.6-times delayed breakthrough of $Mn^{2+}$ was observed in the presence of NaClO. This result also supports that the removal efficiency of the soluble $Mn^{2+}$ could be enhanced by using NaClO.

Preparation and Dissolution Properties of Oral Controlled Release Formulation Containing Carvedilol (카르베딜롤을 함유하는 경구제어 방출형 제제의 제조 및 용출특성)

  • Choi, Won-Sik;Kim, Yong-Nam;Nam, Seok-Woo;Yang, Jin-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2451-2458
    • /
    • 2010
  • We prepared sustained release matrix system which contains carvedilol with Compritol 888 ATO used as lipophilic sustained release excipient and hydroxypropyl methyl cellulose (HPMC) or polyethylene oxide (PEO) used as hydrophilic sustained release polymer. Wet granulation compressed method was used for preparing carvedilol sustained release matrix tablets. When carvedilol sustained release matrix tablets were prepared, we evaluated the drug release kinetics which is affected by Compritol 888 ATO ratio, a kind of hydrophilic polymer (HPMC, PEO) and hot melt coating coagglutination (HMCC) process was done. The drug release kinetics was measured for 24 hours in pH 1.2 simulated gastric fluid and pH 6.8 simulated intestinal fluid, using a dissolution tester at $37.5^{\circ}C$ in 50 rpm. Dissolution rate of controlled release matrix tablets of carvedilol was evaluated by paddle method. We confirmed that HMCC process was very effective to controlled release of drugs. The rate of Compritol 888 ATO, as a lipidic material, can control the drug release pattern about the elution rate of 95% and 24 hours delay than that of the normal tablet.

Improvement of Electron Emission Characteristics and Emission Stability from Metal-coated Carbon Nanotubes (금속 코팅된 탄소나노튜브의 전계 방출 특성 및 신뢰성 향상)

  • Uh, H.S.;Park, S.;Kim, B.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.436-441
    • /
    • 2011
  • Metal coating with several nanometer thickness was applied on the carbon nanotubes (CNTs) in order to improve electron emission characteristics and emission reliability for the potential applications in the area of various electron sources and displays. CNTs were grown on the 2-nm thick Invar (52% Fe, 42% Ni, 6% Co alloy)-catalized Si substrate by using plasma-enhanced chemical vapor deposition at $450^{\circ}C$. In order to reduce the spatial density of densely packed CNTs, as-grown CNTs were partly etched back by $N_2$ plasma and subsequently coated with 5~150 nm thick Ti by a sputtering method. 5 nm thick Ti-coated CNTs produced four times higher emission current density at the electric field of 6 V/${\mu}m$ and much lower emission current fluctuation, compared with the as-grown CNTs. These improved emission properties are mainly due to not only the work function of Ti (4.3 eV) lower than that of pristine CNTs (5 eV), but also lower contact resistance and better adhesion between CNT emitters and substrate accomplished by Ti coating.

A Study on the Properties and Utilization of Chitosan Coating 2. Changes in the Quality of Tomatoes by Chitosan Coating (게껍질에서 추출한 chitosan 필름의 이용에 관한 연구 2. Chitosan 코팅처리한 토마토의 품질변화)

  • KIM Hyonng-Seub;SON Byung-Yil;PARK Seong-Min;LEE Keun-Tai
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.5
    • /
    • pp.568-572
    • /
    • 1999
  • Coating with chitosan ($2\%$, pH: 5.0) had a beneficial effect such as less weight loss, flesh firmness and maintenance of sugar content of tomatoes stored at the normal temperature. The weight loss of chitosan-coated tomatoes was $4.8\%$ during the storage-period (18days) while that of control was $10.2\%$. When it was stored for 18 days, the tomatoes coated with chitosan showed higher in firmness (1.63 kg) and pectin content ($0,58g\%$) than the control (1.03 kg, $0.44g\%$). For the total soluble acid and pH, the tomatoes coated with chitosan were higher in oxalic acid ($0.17 g\%$) than the control ($0.15 g\%$) and the latter were higher in the pH than the former, when they were stored for 18 days.

  • PDF

Decomposition of Low-toxic Propellant by Cu-La-Al/honeycomb Catalysts (Cu-La-Al/honeycomb 촉매를 이용한 저독성 추진제 분해)

  • Kim, Munjeong;Yoo, Dalsan;Lee, Jeongsub;Joen, Jong-Ki
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.296-303
    • /
    • 2021
  • The objective of this study is to investigate the applicability of a Cu-supported honeycomb catalyst as a catalyst for decomposition of a low toxic liquid propellant based on ammonium dinitramide (ADN). A mixture of copper, lanthanum, and alumina was supported on the honeycomb support by wash coating to prepare a Cu-La-Al/honeycomb catalyst. We elucidated that the effect of metal loading on the physicochemical properties of Cu-La-Al/honeycomb catalyst and catalytic performance in decomposition of the ADN-based liquid propellant. As the number of wash coatings increased, the amount of active metal Cu was increased to 4.1 wt%. The BET surface area of the Cu-La-Al/honeycomb catalyst was in the range of 3.1~4.1 ㎡/g. The micropores were hardly present in Cu-La-Al/honeycomb catalysts, however, the mesopores and macropores were well developed. The Cu (2.7 wt%)-La-Al/honeycomb catalyst exhibited the highest activity in the decomposition of the ADN-based liquid propellant, which is attributed to the largest surface area, the largest pore volume, and the well-developed mesopores and macropores.

The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304 (Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과)

  • Kim, Dong-Guk;Song, Tae-Ha;Jeong, Yong-Hoon;Kang, Kwan-Su;Yoon, Deok-kyu;Kim, Min-Uk;Woo, Young-Jae;Seo, Yo-Han;Kim, Kyung-Ah;Roh, Ji-hyoung
    • Journal of Surface Science and Engineering
    • /
    • v.55 no.6
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.