• Title/Summary/Keyword: coal power plant

Search Result 534, Processing Time 0.034 seconds

The Best Generation Mix considering CO2 Air Pollution Constraint ($CO_2$ 배출량제약을 고려한 최적전원구성)

  • Lee, Sang-Sik;Tran, TrungTinh;Kwon, Jung-Ji;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.149-151
    • /
    • 2005
  • A new approach considering CO2 air pollution constraints in the long-term generation mix is proposed under uncertain circumstances. A characteristic feature of the presented approach in this paper is what effects give the air pollution constraints in long term best generation mix. Best generation mix problem is formulated by linear programming with fuel and construction cost minimization with load growth, reliability (reserve margin rate) and air pollutionconstraints. The proposed method accommodates the operation of pumped-storage generator. It was assumed in this study that the construction planning of the hydro power plants is given separately from the other generation plans. The effectiveness of the proposed approach is demonstrated by applying to the best generation mix problem of KEPCO-system, which contains nuclear, coal, LNG, oil and pumped-storage hydro plant multi-years.

  • PDF

Characteristic of $Ca^{2+}$ Ion Exchange by the Synthesized Zeolite 4A from Fly ash (비산회로부터 합성한 제올라이트의 4A의 칼슘 이온교환 특성)

  • 연익준;주소영;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.165-171
    • /
    • 1999
  • A study on the synthesis of zeolite 4A using the bituminous coal fly ash from power plant was carried out. This study aims to investigate possibility for detergent builder with synthesized zeolite. It was examined at the crystallization conditions of atmospheric pressure and that of pressurization. The synthesized zeolite was proved to be Zeolite 4A type by means of the XRD and SEM analysis, and then the synthesized zeolite was used as an absorbent the remove the $Ca^{2+}$ ions in the water. In this study, commercial zeolite and synthesized zeolite reached equilibrium within 10 and 30 minutes respectively. The amount of $Ca^{2+}$ ions exchanged by the commercial zeolite, atmospheric pressure zeolite (zeolite A) and pressurized zeolite(zeolite PA) were 391mg/L(as $CaCO_3$), 323mg/L(as $CaCO_3$) and 355mg/L(as $CaCO_3$) respectively.

  • PDF

Comparison of Geotechnical Characteristics of Bottom Ash for Lightweight Fill Material (경량 성토재 활용을 위한 석탄 저회 물성 비교)

  • Kim, Yun-Ki;Lee, Sung-Jin;Shin, Min-Ho;Lee, Seung-Rae;Lee, Yong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.679-686
    • /
    • 2010
  • Mechanical characteristics of bottom ash produced in coal-fired power plant are investigated to utilize as light-weight fill materials. Triaxial compression test, water retention test, and unsaturated direct shear test were conducted for weathered soil (WS), reclaimed bottom ash (RBA), and screened bottom ash (BA). RBA had larger frictional angle and lower effective cohesion than those of WS. Water retention charactersitics of RBA and BA existed within distributions of soil-water characteristic curves for domestic weathered soils. Unsaturated shear strength of RBA was similar to that of WS at matric suctions of 50 kPa and 100 kPa. As a conclusion, bottom ash can be used as fill materials to replace the conventional construction materials by.

  • PDF

A Study on the material characteristics of Waste Recycling Concrete combined with Fly and Bottom Ash produced by Gangwon Area (보령화력발전소 부산물을 재활용한 혼합형 숏크리트의 압축강도 특성 연구)

  • Lee, Sang-Moon;Choi, Hyun-Kyu;Jung, Woo-Young;Park, Chul-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.381-382
    • /
    • 2009
  • This research presents early characters of waste recycling shotcerete with a combination of Coal-Ash are used by Bo-Ryung thermoelectric power plant. Several tests were conducted in this research.

  • PDF

A Study on Air and Gas System of Coal Fired Power Plant (석탄화력발전소의 공기 및 가스시스템 모델에 관한 연구)

  • Jung, Hwan-Joo;Kim, Tae-Hyun;Ryoo, Young-Jae;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.283-285
    • /
    • 2002
  • Boiler combustion systems are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems. dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, pulverizer, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF

A Study on the Construction of flexible Best Generation Mix with fuzzy Multi-criterion Function (퍼지 다목적함수(多目的函數)를 갖는 유연(柔軟)한 최적전원구성(最適電源構成)의 수립에 관한 연구(硏究))

  • Song, Kil-Yeong;NamGung, Jae-Young;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.103-105
    • /
    • 1992
  • The new approach using fuzzy linear programming with fuzzy multi-criterion is proposed for the best generation mix of a power system. A chracteristic feature of the presented approach is that not only cost but also reliability for goal function can be taken into account by using fuzzy multi-criterion and so more realistic solution can be obtained. The effectiveness of the proposed approach is demonstrated by the best generation mix problem of KEPCO-system size model which contains nuclear, coal, LNG, oil and pump-generator hydro plant in multi-years.

  • PDF

Removal Characteristics of Heavy Metal by Na-P1 Zeolite Synthesized from Coal Fly Ash

  • Lee Mingyu;Lee Donghwan;Oh Yunghee;Ahn Byoungjoon
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.2
    • /
    • pp.167-175
    • /
    • 1997
  • This study was conducted for an efficient utilization of waste fly ash obtained from the power plant. Fly ash was used for synthesizing zeolite. Na-P1 zeolite could be easily synthesized from waste fly ash and showed the potential to remove heavy metal ions. The synthetic zeolite showed good adsorption property for heavy metal much better than raw fly ash and natural zeolites. Na-P1 exhibited the high adsorption efficiency with a maximum value of 260 Pb mg/g and strong affinity for $Pb^{2+}$ ion. The metal ion selectivity of Na-P1 was determined in a decreasing order : $Pb^{2+}>Cd^{2+}>Cu^{2+}>Zn^{2+}>Fe^{3+}$.

  • PDF

Preparation and Activity of the Extruded SCR Catalyst for NOx Reduction in Coal Fired Power Plant (석탄화력발전소 질소산화물 제거를 위한 압출성형 SCR 촉매의 제조 및 활성)

  • 이인영;김동화;이정빈;김우영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.143-144
    • /
    • 2001
  • 질소산화물(NOx) 제거기술 중, 선택적촉매환원(Selective Catalytic Reduciton: SCR)공정은 배기가스 중에 포함되어 있는 질소산화물을 암모니아와 촉매상에서 반응시켜 무해한 질소와 물로 전환하는 기술로 높은 탈질율 및 안정적인 기술로 인하여 상업적으로 널리 이용되고 있다(Bosch, 1988). 귀금속촉매, Cu/Zeolite 촉매 및 V$_2$O$_{5}$/TiO$_2$ 등 다양한 촉매들이 SCR 공정에 적용되는데 V$_2$O$_{5}$/TiO$_2$ 촉매가 높은 활성과 황 등 피독 물질에 대한 우수한 내구성으로 인하여 가장 효과적인 촉매로 알려져있다(Heck, 1999). (중략)

  • PDF

The Characteristics of Compressive Strength and Leachability on Solidification of Chromium Tannery Sludge adding to Coal Fly Ash (비산회를 첨가한 피혁공장 크롬 슬러지의 고화시 압축강도 및 용출 특성)

  • 주소영;연익준;신필식;전병진;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.53-60
    • /
    • 2001
  • In this study, the heavy metals in tannery sludge were solidified by using cement and power plant fly ash. Solidification characteristics were discussed with the compressive strength and chromium leaching characteristics of solids. The compressive strength of cement mortar was increased by the amount of fly ash up to 24.3~33.8%, which was considered the results of pozzolanic reaction. When the content of fly ash was 20%, cement mortar showed the highest value $295kg/\textrm{cm}^2$ for 28 days curing. At early curing days, solidified chromium tannery sludge solids were showed lower compressive strength because of the retard on the hydration of cement, but the compressive strength was recovered to be more than $140kg/\textrm{cm}^2$ for 28 days curing regardless with the amounts of fly ash. Also, the results of leaching tests by KSM and TCLP method were showed that the solidified chromium sludge have leached out 0.3~2.2% and 11~17%, respectively.

  • PDF

Minimization of Energy Consumption for Amine Based CO2 Capture Process by Process Modification

  • Sultan, Haider;Bhatti, Umair H.;Cho, Jin Soo;Park, Sung Youl;Baek, Il Hyun;Nam, Sungchan
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.13-18
    • /
    • 2019
  • The high energy penalty in amine-based post-combustion CO2 capture process is hampering its industrial scale application. An advanced process is designed by intensive heat integration within the conventional process to reduce the stripper duty. The study presents the technical feasibility for stripper duty reduction by intensive heat integration in CO2 capture process. A rigorous rate-based model has been used in Aspen Plus® to simulate conventional and advanced process for a 300 MW coal-based power plant. Several design and operational parameters like split ratio, stripper inter-heater location and flowrate were studied to find the optimum values. The results show that advanced configuration with heat integration can reduces the stripper heat by 14%.