• 제목/요약/키워드: coagulation pretreatment

검색결과 83건 처리시간 0.03초

제주도 매립장 침출수 중 유기물의 효율적 처리를 위한 광촉매 분해 반응의 응용 (Application of Photocatalytic Degradation for Efficient Treatment of Organic Matter in Landfill Leachate in Jeju Island)

  • 이창한;이택관;조은일;감상규
    • 한국환경과학회지
    • /
    • 제31권8호
    • /
    • pp.677-689
    • /
    • 2022
  • In order to photocatalytically treat organic matter (CODCr) and chromaticity effectively, chemical coagulation and sedimentation processes were employed as a pretreatment of the leachate produced from landfill in Jeju Island. This was performed using FeCl3·6H2O as a coagulant. For the treated leachate, UV/TiO2 and UV/TiO2/H2O2 systems were investigated, using 4 types of UV lamps, including an ozone lamp (24 W), TiO2 as a photocatalyst, and/or H2O2 as an initiator or inhibitor for photocatalytic degradation. In the chemical coagulation and sedimentation process using FeCl3·6H2O, optimum removal was achieved with an initial pH of 6, and a coagulant dosage of 2.0 g/L, culminating in the removal of 40% CODCr and 81% chromaticity. For the UV/TiO2 system utilizing an ozone lamp and 3 g/L of TiO2, the optimum condition was obtained at pH 5. However, the treated CODCr and chromaticity did not meet the emission standards (CODCr: 400 mg/L, chromaticity: 200 degrees) in a clean area. However, for a UV/TiO2/H2O2 system using 1.54 g/L of H2O2 in addition to the above optimum UV/TiO2 system, the results were 395 mg/L and 160 degrees, respectively, which were within the emission standard limits. The effect of the UV lamp on the removal of CODCr, and chromaticity of the leachate decreased in the order of ozone (24 W) lamp > 254 nm (24 W) lamp > ozone (14 W) lamp > 254 nm (14 W) lamp. Only CODCr and chromaticity treated with the ozone (24 W) lamp met the emission standards.

도시의 분산형 생활오수 재생시스템에 화학적 전처리공정도입에 관한 연구 (A Study on the Application of Pre-Chemical Treatment on the Decentralized Domestic Wastewater Reclamation System)

  • 이상우;박영미;서규태
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.115-121
    • /
    • 2006
  • The purpose of this study was to investigate applicability of pretreatment on the existing biological treatment for domestic wastewater reclamation. From Jar Tests, it was found that optimum dosage of coagulant was PAC 0.5mg/L and $FeCl_3$ 180mg/L for urban sewage. In this study, PAC 0.5mg/L was selected considering sludge production and the amount of coagulant required. In a continuous experiment performed with combining chemical coagulation and biological treatment, a considerable removal efficency was obtained in term of BOD, SS, T-N, T-P and ABS. When the raw sewage was supplied into the pre-chamical treatment facility, the removal of BOD and SS was 48.3% and 81.1%. However T-N removal was very low which means T-N consists of $NH_3-N$ mostly. T-P was almost completely recluced by the chemical addition. The effluent BOD & SS was 57~76 and 21~43mg/L, which could reduce the size of biological treatment facility. From the cost estimation pre-chemical treatment could save around half of the area required for biological treatment with post ceagulation.

정수장 유입조류 저감을 위한 전처리 시스템 개발 (Development of pretreatment system for algae reduction in water treatment plant)

  • 윤상린
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.1-1
    • /
    • 2017
  • 녹조현상은 부영양화된 호수나 유속이 느린 하천에서 부유성의 조류(식물 플랑크톤)가 대량 증식하여 수면에 집적하게 되고 물의 색을 현저하게 녹색으로 변화시킴으로써 발생된다. 최근에는 이러한 녹조 현상이 광역화, 독성화, 장기화의 특성을 띠며 빈번히 발생되고 있다. 녹조현상은 독소를 발생시키는 남조류에 의해 수생식물에 악영향을 주는 것으로 알려져 있다. 예를 들면 독소에 의한 가축에의 영향, 생태계 파괴로 인한 생태학적인 문제, 산소결핍으로 인한 물고기 및 각종 수중생물 폐사 등의 심각한 문제를 야기한다. 또한 조류는 식수에서 맛과 냄새를 유발할 뿐 아니라 Microcystin-LR과 같은 유해한 독소를 배출하여 공중 보건을 위협한다. 이에 식수원으로 사용되는 하천의 조류 번식에 따른 대응방안 마련이 절실히 요구된다. 유입되는 조류로 부터의 정수처리 설비의 처리 부하를 줄이기 위해서는 취수시스템과 연계한 고속 전처리 조류 제거 시스템을 개발이 필요하다. 기존의 전기응집부상공정(Electro-Coagulation and Flotation, ECF)은 화학 약품(응집제) 투여량이 적은 이점이 있지만 비교적 긴 전기 분해 시간이 필요하여 기존 정수처리 시스템과 연계성에 있어 한계가 있다. 이에 본 연구는 전기 분해 시간을 줄여 유입된 조류를 수 초 내에 응집하여 1분 이내에 조류를 분리하는 초고속 조류 전처리 기술을 개발하였다. 개발된 기술의 현장적용 및 실험 결과, 응집과정이 없이도 Chlo-a는 약 45 %의 제거 효율을 나타났다. 또한 응집제의 투입 및 전극에 의한 부상시스템에 의해 Chlo-a가 약 80 %로 제거되는 것으로 나타나 빈번하게 발생되는 조류로부터 안정적인 물 공급을 위한 전처리 공정으로 활용이 가능할 것으로 판단된다.

  • PDF

An anesthetic management of head and neck cancer reconstructive surgery in a patient having hemophilia A: a case report

  • Ryoo, Seung-Hwa;Kwon, Dohyun;Lee, Jong-Ho;Seo, Kwang-Suk;Kim, Hyun Jeong;Karm, Myong-Hwan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권3호
    • /
    • pp.261-268
    • /
    • 2021
  • Hemophilia A is a hemorrhagic disease caused by coagulation factor VIII deficiency. In head and neck cancer surgery, especially during a reconstructive one, complications can occur. These include hematomas due to bleeding which can then lead to flap ischemia, necrosis, and impaired wound healing. There are fewer cases of reconstructive surgery in patients with hemophilia A. Here in we report, a reconstructive surgery that involved mass resection, partial glossectomy (right), selective neck dissection (right, Levels I, II, III, IV), and reconstruction at the lateral arm free flap (left) in a 25-year-old man with hemophilia A. The surgery was successfully performed without any complications after pretreatment with Factor VIII concentrate, which has not been reported earlier.

Fenton 및 Photo-Fenton 산화공정을 이용한 염색 폐수의 처리에 관한 연구 (A Study on the Dye-Wastewater Treatment by Fenton and Photo-Fenton Oxidation Process)

  • 조일형;고영림;이소진;이홍근;조경덕
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.29-37
    • /
    • 2000
  • Fenton’s oxidation process is one of the most commonly applied processes to the wastewater which cannot be treated by conventional biological treatment processes. However, it is necessary to minimize the cost of Fenton’s oxidation treatment by modifying the treatment processes or other means of chemical treatment. So, as a method for the chemical oxidation of biorefractory or nonbiodegradable organic pollutants, the Photo-Fenton-Reaction which utilizes iron(11)salt. $H_2O$$_2$ and UV-light simultaneously has been proprosed. Therfore, the purpose of this study is to test a removal efficiency of dye-wastewater and treatment cost with Fenton’s and Photo-Fenton’s oxidation process. The Fe(11)/$H_2O$$_2$ reagent is referred to as the fenton’s reagent. which produces hydroxy radicals by the interaction of Fe(11) with $H_2O$$_2$. In this exoeriment, the main results are as followed; 1. The Fenton oxidation was most efficient in the pH range of 3-5. The optimal condition for initial reaction pH was 3.5 for the high CO $D_{Cr}$ & TOC-removal efficiency. 2. The removal efficiency of TOC and CO $D_{Cr}$ increased up to the molar ration between ferrate and hydrogen peroxide 0.2:1, but above that ratio removal efficiency hardly increased. 3. The highest removal efficiency of TOC and CO $D_{Cr}$ were showed when the mole ration of ferrate to hydrogen peroxide was 0.2:3.4. 4. Without pretreatment process, photo-fenton oxidation which was not absorbed UV light was not different to fenton oxidation. 5. And Fenton oxidtion with pretreatment process was similar to Fenton oxidation in the absence of coagulation, the proper dosage of F $e^{2+}$: $H_2O$$_2$ was 0.2:1 for the optimal removal efficiency of TOC or CO $D_{Cr}$ .6. Also, TOC & CO $D_{Cr}$ removal efficiency in the photo-fenton oxidation with pretreatment was increased when UV light intensity enhanced.7. Optimum light intensity in the range from 0 to 1200 W/$m^2$ showed that UV-intensity with 1200W/$m^2$ was the optimum condition, when F $e_{2+}$:$H_2O$$_2$ ratio for the highest decomposition was 0.2:2.5.EX>$_2$ ratio for the highest decomposition was 0.2:2.5.

  • PDF

완속모래여과 공정에서 세라믹 MF 막의 적용 (Application of Ceramic MF Membrane at the Slow Sand Filtration Process)

  • 최광훈;박종율;김수한;김정숙;강임석
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.877-882
    • /
    • 2013
  • 최근 음용수를 위한 UF, MF 막의 적용이 증가하고 있다. UF/MF 막은 재래식 수처리 공정에 비하여 원수 수질 변화에도 안정적인 운전이 가능하고 부지 면적이 작으며 자동화 운전이 가능하다는 장점을 가지고 있다. 현재 대부분의 UF/MF 막시설은 고분자 막을 사용하고 있다. 최근 세라믹 막은 고분자막에 비하여 경쟁력이 있다고 알려지고 있다. 세라믹 막은 높은 투과유량과 약품세정 빈도가 작으며 막의 수명 또한 길어 최근 적용 사례가 증가하고 있다. 따라서 본 연구는 MF 세라믹 막 pilot plant를 완속모래여과 정수장에 적용하였다. 본 연구에 사용된 세라믹 Pilot plant는 3개의 계열이 있으며, 각 계열별로 원수와 모래 여과수를 막의 유입수로 각각 사용하였다. 또한 세라믹 막 공정의 최적화를 위하여 전처리 응집공정으로서 PACl 응집제를 사용하였다. 그리고 화학세정(Chemical Enhanced Backwashing, CEB)은 황산 (500 mg/L)과 차아염소산 (200 mg/L)을 1.5일에 1번씩 모든 계열에 주입하여 이루어졌다. 본 연구 결과 세라믹 막 공정의 전처리 응집공정에서 최적의 응집제 사용은 막의 유입수로 원수와 모래 여과수에 대한 막의 flux를 크게 증가시켰다. 또한 본 연구에서 사용된 최적 응집제 주입량에서 차압상승률은 원수(25 mg/L)의 경우 2.173 kPa/cycle이며, 모래 여과수(5 mg/L)의 경우 0.301 kPa/cycle으로 나타났다.

Mastitis Diagnostics by Near-infrared Spectra of Cows milk, Blood and Urine Using SIMCA Classification

  • Tsenkova, Roumiana;Atanassova, Stefka
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1247-1247
    • /
    • 2001
  • Constituents of animal biofluids such as milk, blood and urine contain information specifically related to metabolic and health status of the ruminant animals. Some changes in composition of biofluids can be attributed to disease response of the animals. Mastitis is a major problem for the global dairy industry and causes substantial economic losses from decreasing milk production and reducing milk quality. The purpose of this study was to investigate potential of NIRS combined with multivariate analysis for cow's mastitis diagnosis based on NIR spectra of milk, blood and urine. A total of 112 bulk milk, urine and blood samples from 4 Holstein cows were analyzed. The milk samples were collected from morning milking. The urine samples were collected before morning milking and stored at -35$^{\circ}C$ until spectral analysis. The blood samples were collected before morning milking using a catheter inserted into the carotid vein. Heparin was added to blood samples to prevent coagulation. All milk samples were analyzed for somatic cell count (SCC). The SCC content in milk was used as indicator of mastitis and as quantitative parameter for respective urine and blood samples collected at same time. NIR spectra of blood and milk samples were obtained by InfraAlyzer 500 spectrophotometer, using a transflectance mode. NIR spectra of urine samples were obtained by NIR System 6500 spectrophotometer, using 1 mm sample thickness. All samples were divided into calibration set and test set. Class variable was assigned for each sample as follow: healthy (class 1) and mastitic (class 2), based on milk SCC content. SIMCA was implemented to create models of the respective classes based on NIR spectra of milk, blood or urine. For the calibration set of samples, SIMCA models (model for samples from healthy cows and model for samples from mastitic cows), correctly classified from 97.33 to 98.67% of milk samples, from 97.33 to 98.61% of urine samples and from 96.00 to 94.67% of blood samples. From samples in the test set, the percent of correctly classified samples varied from 70.27 to 89.19, depending mainly on spectral data pretreatment. The best results for all data sets were obtained when first derivative spectral data pretreatment was used. The incorrect classified samples were 5 from milk samples,5 and 4 from urine and blood samples, respectively. The analysis of changes in the loading of first PC factor for group of samples from healthy cows and group of samples from mastitic cows showed, that separation between classes was indirect and based on influence of mastitis on the milk, blood and urine components. Results from the present investigation showed that the changes that occur when a cow gets mastitis influence her milk, urine and blood spectra in a specific way. SIMCA allowed extraction of available spectral information from the milk, urine and blood spectra connected with mastitis. The obtained results could be used for development of a new method for mastitis detection.

  • PDF

호소수 탁도변화 대응을 위한 고플럭스 막여과공정의 Pilot 연구 (A pilot study of high flux membrane process for responding to influent turbidity changes in reservoir water)

  • 강준석;성자영;유제완;김형수;이재규;전민혁;천지훈
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.393-402
    • /
    • 2020
  • In the membrane process, it is important to improve water treatment efficiency to ensure water quality and minimize membrane fouling. In this study, a pilot study of membrane process using reservoir water was conducted for a long time to secure high flux operation technology capable of responding to influent turbidity changes. The raw water and DAF(Dissolved Air Flotation) treated water were used for influent water of membrane to analyze the effect of water quality on the TMP (Trans Membrane Pressure) and to optimize the membrane operation. When the membrane flux were operated at 70 LMH and 80 LMH under stable water quality conditions with an inlet turbidity of 10 NTU or less, the TMP increase rates were 0.28 and 0.24 kPa/d, respectively, with minor difference. When the membrane with high flux of 80 LMH was operated for a long time under inlet turbidity of 10 NTU or more, the TMP increase rate showed the maximum of 43.5 kPa/d. However, when the CEB(Chemically Enhanced Backwash) cycle was changed from 7 to 1 day, it was confirmed that the TMP increase rate was stable to 0.23 kPa/d. As a result of applying pre-treatment process(DAF) on unstability water quality conditions, it was confirmed that the TMP rise rates differed by 0.17 and 0.64 kPa/d according to the optimization of the coagulant injection. When combined with coagulation pretreatment, it was thought that the balance with the membrane process was more important than the emphasis on efficiency of the pretreatment process. It was considered that stable TMP can be maintained by optimizing the cleaning conditions when the stable or unstable water quality even in the high flux operation on membrane process.

하수처리수 재이용을 위한 RO 공정의 타당성 및 막오염 평가 (Evaluation of RO Process Feasibility and Membrane Fouling for Wastewater Reuse)

  • 홍기웅;이상엽;김창우;부찬희;박명균;안호철;홍승관
    • 한국물환경학회지
    • /
    • 제26권2호
    • /
    • pp.289-296
    • /
    • 2010
  • The purpose of this study is to evaluate various pre-treatment methods and proprieties of water quality for wastewater reuse using reverse osmosis (RO) processes. Secondary effluents were sampled from wastewater treatment plants and lab scale pre-treatments and RO filtration test were conducted systematically. Specifically, different types of pre-treatments, such as coagulation, microfiltration and ultrafiltration, were employed to evaluate the removal efficiency of particle and organic matters which may affect the membrane fouling rate. RO process was later added to eliminate trace amounts of remaining organic matters and salt from the raw water for wastewater reclamation. The permeate through the RO process satisfied water quality regulations for industrial water uses. The experimental results showed that the initial fouling tendency differed not only by the feed water properties but also by the membrane characteristics. Membrane fouling was greater for the membranes with large surface roughness, regardless of the hydrophobicity and zeta potentials. Thus both careful consideration of pre-treatment options and proper selection of RO membrane are of paramount importance for an efficient operation of wastewater treatment.

막여과 정수처리공정에서 망간에 의한 막오염 특성 및 화학세정효율 평가 (Evaluation of membrane fouling characteristics due to manganese and chemical cleaning efficiency in microfiltration membrane process)

  • 강준석;박서경;송지영;정아영;이정준;김한승
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.539-549
    • /
    • 2017
  • In water treatment process using microfiltration membranes, manganese is a substance that causes inorganic membrane fouling. As a result of analysis on the operation data taken from I WTP(Water Treatment Plant), it was confirmed that the increase of TMP was very severe during the period of manganese inflow. The membrane fouling fastened the increase of TMP and shortened the service time of filtration or the cleaning cycle. The TMP of the membrane increased to the maximum of $2.13kgf/cm^2$, but it was recovered to the initial level ($0.17kgf/cm^2$) by the 1st acid cleaning step. It was obvious that the main membrane fouling contaminants are due to inorganic substances. As a result of the analysis on the chemical waste, the concentrations of aluminum(146-164 mg/L) and manganese(110-126 mg/L) were very high. It is considered that aluminum was due to the residual unreacted during coagulation step as a pretreatment process. And manganese is thought to be due to the adsorption on the membrane surface as an adsorbate in feed water component during filtration step. For the efficient maintenance of the membrane filtration facilities, optimization of chemical concentration and CIP conditions is very important when finding the abnormal level of influent including foulants such as manganese.