• Title/Summary/Keyword: coagulant agent

Search Result 25, Processing Time 0.023 seconds

Contrasting Correlation in the Inhibition Response of ADP-induced Platelet Aggregation and the Anti-coagulant Activities of Algal fucoidans Derived from Eisenia bicyclis and Undaria pinnatifida sporophylls (Mekabu)

  • Jeong, Eui-Sook;Yoon, Yeon-Hee;Kim, Jong-Ki
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.3
    • /
    • pp.194-202
    • /
    • 2009
  • Sulfated fucans are known to have both anti-thrombotic and anti-coagulant activities. In this study, the variation in platelet aggregation and anti-coagulant activities was investigated in vitro with regard to administered dose, molecular weight distribution, sulfate content, and sugar composition in two algal fucoidans from Eisenia bicyclis and Undaria pinnatifida sporophylls (Mekabu). The anti-coagulant activity largely correlated with sulfate content and with molecular weight distribution in a dose-dependent manner. However, both fucoidans demonstrated inhibitory responses to ADP-induced platelet aggregation in dose- and structure-dependent manners that contrasted with the anti-coagulant activity. Neither molecular weight distribution nor sulfate content greatly affected platelet-aggregation inhibition (PA-inhibition) by the fucoidan fractions, whereas anti-coagulant activity was sensitive to these structural factors. Interestingly, an E. bicyclis fucoidan fraction exhibited almost complete PA-inhibition at a treatment dose of 500 mg/mL while retaining weak anti-coagulant activity. In conclusion, these observations suggest that fucoidan may be a useful anti-thrombotic or anti-platelet agent in various arterial thrombotic disorders, including post-vascular intervention with controlled bleeding complications, due to its anti-coagulant modulating activity.

Comparison of Fe(III) Coagulants and their Characterization for Water Treatment (수처리용 Fe(III)계 응집제의 특성 및 응집특성 비교)

  • Han, Seung Woo;Kang, Lim Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.169-176
    • /
    • 2016
  • This research explored the feasibility of preparing and utilizing preformed polymeric solution of Fe(III) as coagulants for water treatment. The differentiation and quantification of hydrolytic Fe(III) species in coagulant was done by utilizing spectrophotometric method based on the interaction of Fe(III) with Ferron as a complexing agent. The properties of the synthesized polymeric iron chloride (PICl) showed that the quantity of polymeric Fe(III) produced at r = 1.5 was 20% of the total iron in solution, as showing maximum contents. Coagulation experiments were conducted under the condition of various coagulant doses and pH for each coagulant prepared. From the comparison of the characterization of coagulation for $FeCl_3$ (r = 0.0) and PICl (r = 0.5, 1.0, 1.5) coagulants, PICl (r = 0.5, 1.0, 1.5) coagulants was found to be more effective than other coagulant for the removal of organic matters. The experimental results for the coagulation tests at various pH ranges showed that the PICl was least affected by the coagulation pH and PICl was very effective for the removal of turbidity and organic materials over wide pH range (pH 4-9) tested.

Study for the comparative treatment method of industrial wastewater using coagulant and H.V.G (응집제와 정전기 수처리장치에 의한 산업폐수의 비교처리법에 관한 연구)

  • 김재용;정상섭;정성권
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.1-5
    • /
    • 2003
  • For studying out the method of the effective purification of waste waters such as dying, paper pulp and plating wastewater, we measured the COD removal efficiency, color and turbidity of those pollutants by the physical and chemical method using the Inorganic Coagulating Agent (CM, RM) and a High Voltage Generator. The COD removal efficiency measured when applying the Inorganic Coagulating Agent (CM, RM) was mush higher than that using the Existing Coagulating Agent In addition to, when using those two methods above mentioned at the same time, both the COD removal efficiency and the reduction-effect of the inserting quantities of Coagulating Agent were higher than those were used singly. The system using both an Inorganic Coagulating Agent and a High Voltage Generator will be useful in various fields of wastewater treatment.

Study on the Anti-inflammatory Effect of Polysaccharide Extract from Acyranthes bidentata (우슬 다당 추출물의 항염 효과에 관한 연구)

  • Lee, Dae-Woo;Kim, Young-Jin;Kim, Young-Sil;Eom, Sang-Yong;Kim, Jong-Heon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.1
    • /
    • pp.37-42
    • /
    • 2008
  • Acyranthes bidentata has been used as anti-arrthritic, aphrodisiac, anti-viral, anti-spasmodic, anti-hypertensive, anti-coagulant and anti-tumor agent. In this study, we evaluated anti-inflammatory effect of polysaccharide extract from Acyranthes bidentata. Acyranthes bidentata polysaccaride decreased $IL-1{\alpha}$, IL-6, COX-2, and total NO synthesis. Our results point to the potential use of Acyranthes bidentata polysaccaride as a cosmeceutical agent for inflammatory cutaneous symptoms.

Physicochemical Treatment of Waste Water Containing Organic Materials (유기물을 함유한 폐수의 물리화학적 처리에 관한 연구)

  • Lee, Han-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.493-498
    • /
    • 2013
  • The production of synthetic polymer compounds and ethanolamine (ETA, a pH control agent used in nuclear power plants) generates effluent that pollutes water. This study focused on the development of chemicals for the treatment of effluent and processes to reduce the COD level due to the presence of organic materials via physicochemical treatment. It was found that a mixed coagulant of $FeCl_2$ and $MgCl_2$ (1:1) was the most effective in treating effluent and reducing the COD level. When the mixed coagulant was injected into effluent including organic materials, the COD level was reduced by more than 80%.

Thickening of Activated Sludge Using Low Pressure Flotation Pilot System (파일롯 규모의 저압형 부상장치를 이용한 하수슬러지 농축에 관한 연구)

  • Kim, Ji Tae;Oh, Joon Taek;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Low pressure air flotation (LAF) pilot plant for sludge thickening was installed in Chung Nam N.S. municipal waste water treatment plant to verify its application possibility. Effects of operating conditions such as coagulant dosages and microbubble water ratio on thickening of the mixed sludge were examined. Microbubbles which were generated in the chamber of $1.5kgf/cm^2$ by high speed collision method with foaming agent were used to float sludge. Solid loading of $30kg/m^2/hr$, solid contents in thickened sludge of 60,300 mg/L and SS removal efficiency of 99% were obtained through long period operating LAF in conditions of mixed sludge concentration of 14,400 mg/L, coagulant dosage of 27.6 mg/L, foaming agent addition of 4.0 mg/L and microbubble water injection ratio of 9.7%.

A Study on Purification of Water Works by Multi-filter Bed Method with Aeration(Appliction of Biological Oxidation by Aerobic Microorganism) (상수 정화법에 관한 연구 (폭기식 다단여과에 의한 호기성균의 생물화학적 산화작용을 응용))

  • Chung, Yo-Han;Moon, Jae-Kyu;Jhoo, Heung-Kyu;Seo, Hwa-Jung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 1972
  • 5 bed sand filter, applying biological oxidation, was designed and studied on the treatment of water works. Never using any coagulant agent (drugs), which may cause water pollution in pre-treatment of head water, the auther attempt a high rate filtration by the microorganism (nitrofication bacteria) end plant which populate in multi layer sand beds. The result are as follows : In order to evaluate the oxygen effect on filtration, oxygen was injected in aeration tank attached to each filter tank while filtration, and $NH_3$ was tested as a representaiive ingredient. It was found out that the aeration method was more effective, with over 33% of $NH_3$ removal capacity, than the anerobic and this 5 bed filter showed double removal capacity of $NH_3$ by comparing with conventional sand bed (2 stage bed). According to the examination of two kind of head water, pre-treated with coagulant agent and activated carton, the filtration capacity was affected by the polluted condition of head water, resulting that lower value of pollution and slower velocity of filtration showed more efficiency of $NH_3$ removal. In this experiment $NH_3$ content tested in treated water had a fairly good correlation with others.

  • PDF

Soybean Wastewater Treatment by Activated Sludge Process (고농도 대두가공폐수의 처리를 위한 개선 활성슬러지법)

  • Cho, Kwon-Ik;Lee, Jeoung-Su;Lee, Tae-Kyoo;Kim, Jong-Hwa
    • Applied Biological Chemistry
    • /
    • v.45 no.1
    • /
    • pp.25-29
    • /
    • 2002
  • The kernel of wastewater treatment by activated sludge is elimination of organic substances and maintenance of well-flocculated sludge sedimentation. By the conventional activated sludge treatment, the optimum F/M ratio of soybean wastewater treatment was 0.24 (kg-BOD/kg-MLVSS day) and sludge bulking was generated at 0.48 (kg-BOD/kg-MLVSS day). To improve the treatment capacity and operation quality in higher loading of soybean wastewater, influent pH was constantly controlled by 9.0 using NaOH as a coagulant agent. In this process, higher loading up to 2.88 (kg-BOD/kg-MLVSS day) was possible and SVI was maintained under 150 without bulking. This was equivalent to 7.2 times higher than maximum permissible load of the conventional activated sludge process.

Minimizing of Residual Aluminum in Water Treatment Process (정수처리공정에서 잔류 알루미늄 최소화 방안)

  • 이미영;조덕희;박종현
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2004.11a
    • /
    • pp.54-65
    • /
    • 2004
  • Use of aluminum salts as coagulants In water treatment may lead to increased concentrations of aluminum in finished water. Aluminum is a suspected causative agent of neurological disorders such as Alzheimer's disease. The objective of this study was to examine variation and minimizing in residual aluminum concentration during water treatment process. The aluminum sources at Bokjeong Water Plant were present naturally aluminum in the raw water and derived due to use of PACS as a coagulant. Much of the raw water total aluminum were in particulate and suspended aluminum. In this study was compared the optimize condition to minimize the concentration of residual aluminum using Jar-test with the various coagulants such as alum, PAC, PACS. The results indicated that PACS was more effective than alum, PAC and insufficient or excessive alum, PAC, PACS addition led to increase residual aluminum. Adjustment raw water pH $6.5\~7.0$ before coagulation using PACS was capable of minimizing total and dissolved aluminum. Thus it is important that the optimal dosage of coagulant and the optimal pH adjustment before coagulation can decided to minimize the concentration of residual aluminum in treated water.

  • PDF

Comparison of the characteristics of Al(III) hydrolyzed species by improved ferron assay test (개선된 Ferron 분석 비교를 통한 Al(III) 가수분해종 특성 연구)

  • Yoon, Mihyoung;Kang, Limseok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.3
    • /
    • pp.177-186
    • /
    • 2022
  • In this study, newly improved Ferron assay test haved on timed spectrometry was used for the determination of hyolrolytic Al species presented in PACl coagulant. The color development reagent ferron was prepared by using conventional method and two newly developed methods. Then the ferron assay test was used to compare and analyze the distribution of Al(III) hydrolyzed species presented in the prepared PACl and alum. The preparing method of reagent A required an aging period of 7 days by adding a hydroxylamine hydroxide and a 1,10-phenanthroline monohydrate reagent, whereas the preparing method of reagent B was used as a coloring agent immediately without aging time. The regression analysis between UV absorbance and Al concentrations of conventional method and newly developed method of ferron reagents in low-concentration aluminum solutions and high-concentration aluminum solutions, showed the correlation coefficients of 0.999 or higher, as showing high correlations of conventional method and newly developed method. Applying Ferron assay test, Al species in the PACls and alum were classified as Ala(monomeric Al), Alb (polymeric Al), and Alc (colloidal and precipitated Al). Distribution of Al(III) hydrolyzed species according to the preparation of ferron colorimetric reagents was similar.