• 제목/요약/키워드: co-rotation

검색결과 364건 처리시간 0.028초

EFFECTS OF DIFFERENTIAL ROTATION ON THE CO LINE PROFILES

  • Park, Y.S.;Yun, H.S.;Hong, S.S.;Lee, H.M.
    • 천문학회지
    • /
    • 제25권2호
    • /
    • pp.67-78
    • /
    • 1992
  • Effects of cloud rotation 011 the profiles of CO J=$1{\rightarrow}0$ lines arc investigated by theoretically general ing line profiles under physical conditions similar to t he ones in large globules. The synthesized profiles are presented and their characteristics are discussed. It is found that when the Doppler shift of the observed CO lines is interpreted as the rotation velocity, the optically thin $^{13}CO$ lines underestimate the rotation velocity by up to 10 percents, while the self-reversed optically thick $^{12}CO$ lines overestimate the velocity up to 20 percents. The optically thin line is shown to be of use in probing the distribution of rotation velocity in dark globules.

$^1H$ NMR Study of 4-Aminopyrimidine Coordinated to the Paramagnetic Undecatung-stocobalto(Ⅱ)silicate Anion: Rates of Internal Rotation of the Amine Group

  • 김병안;소현수
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권10호
    • /
    • pp.1149-1152
    • /
    • 1999
  • 1H NMR spectrum of a DMF-d7 solution containing 4-aminopyrimidine and [SiW11CoIIO39]6- (SiW11Co) shows separate peaks from two linkage isomers, a and b, in which N(1) and N(3) of the pyrimidine ring are coordinated to SiW11Co, respectively. The signal from the amine group in the isomer a exhibits temperature dependence that is characteristic of a two-site exchange problem. Rates of internal rotation of the amine group were determined by simulating the NMR spectra at 5-35℃. The amine group of free 4-aminopyrimidine also shows temperature-dependent spectra at lower temperatures; rates of internal rotation at (-25)-25℃ were determined. The internal rotation of the amine group in the complex is much slower than that for free 4-aminopyrimidine, indicating that π-character of the C-N bond increases on coordination to SiW11Co. The amine group in the isomer b does not show such behavior. It is probable that hydrogen bonding between N-H and a bridging oxygen atom of SiW11Co prevents it from rotating at low temperatures.

전신 기울임 운동시 축 회전 유무에 따른 체간근 활성도 변화 (Changes of Muscle Activation Pattern of Trunk Muscles during Whole-body Tilts with and without Axial Rotation)

  • 김솔비;장윤희;김신기;배태수;문무성;박종철
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.805-810
    • /
    • 2012
  • Determining of the exercise intensity is very important in terms of induction of low fatigue during exercise. Little information is available on the contraction level of the trunk muscles during whole body tilts with and without axial rotation. This study was to investigate the difference muscle activation level according to axial rotation. Twenty subjects were participated. The muscle activities of the five trunk muscles were bilaterally measured at eight axial rotation angles with 12 tilt angles along $15^{\circ}$ intervals. The results showed that tilt with $45^{\circ}$ axial rotation was more balanced in the same tilt angle and was maintained approximately level of 40% MVC at over $60^{\circ}$ tilt angle with respect to co-contraction of abdominal and back muscle. Lumbar stabilization exercise using whole body tilts would be more effective with axial rotation than without axial rotation in terms of muscle co-contraction.

편광 변조 방법에 의한 자기 Kerr 회전각 및 Faraday 회전각 측정 (Measurement of magnetic kerr rotation and faraday fotation angles by polarization modulation method)

  • 이용호;이상수;이용호
    • 한국광학회지
    • /
    • 제3권2호
    • /
    • pp.105-110
    • /
    • 1992
  • 광자기 기록 박막의 자기 광학효과에 의한 미소 편광 회전각을 축정하기 위하여 편광 변조 방법을 이용하였다. 편광 변조 방법은 Faraday 회전자로 레이저광의 편광을 변조하고 phase sensitive detection방법을 써서 변조된 신호만을 선택적으로 검출하는 것이다. 본 실험에서는 진공증착법으로 제작된 TbFeCo박막과 RF 스퍼터링으로 제작된 iron garnet 다결정 박막의 자기 Kerr 회전 및 Faraday 회전 이력곡선을 이 방법으로 조사하였다. 그 결과 $0.25^{\circ}$정도의 미소한 회전각을 측정하였으며 특히 longitudinal Kerr 회전의 경우 $2.5\times10^{-3^\circ}$정도의 매우 작은 회전각도 측정할 수 있었다.

  • PDF

내연기관 밸브회전 거동에 관한 해석적 연구 (An Analytic Study on the Valve Rotation Behavior of an Internal Combustion Engine)

  • 김도중;윤재원;김진웅;송진욱
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.184-193
    • /
    • 2006
  • Rotation of intake and exhaust valves are very closely related to the long term durability of automotive engines. If the valves do not rotate even at a rated engine speed, it causes the uneven wear of the valve seat and valve head contact area, which eventually shortens the engine life. A principle of valve rotation mechanism was presumed based on some findings from experiments, and computer programs were developed to simulate the valve rotation phenomena. In this study we investigated the valve rotation mechanism by using the computer simulation models.

Verification of Two Least-Squares Methods for Estimating Center of Rotation Using Optical Marker Trajectory

  • Lee, Jung Keun
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.371-378
    • /
    • 2017
  • An accurate and robust estimation of center of rotation (CoR) using optical marker trajectory is crucial in human biomechanics. In this regard, the performances of the two prevailing least-squares methods, the Gamage and Lasenby (GL) method, and the Chang and Pollard (CP) method, are verified in this paper. While both methods are sphere-fitting approaches in closed form and require no tuning parameters, they have not been thoroughly verified by comparison of their estimation accuracies. Furthermore, while for both methods, results for stationary CoR locations are presented, cases for perturbed CoR locations have not been investigated for any of them. In this paper, the estimation performances of the GL method and CP method are investigated by varying the range of motion (RoM) and noise amount, for both stationary and perturbed CoR locations. The difference in the estimation performance according to the variation in the amount of noise and RoM was clearly shown for both methods. However, the CP method outperformed the GL method, as seen in results from both the simulated and the experimental data. Particularly, when the RoM is small, the GL method failed to estimate the appropriate CoR while the CP method reasonably maintained the accuracy. In addition, the CP method showed a considerably better predictability in CoR estimation for the perturbed CoR location data than the GL method. Accordingly, it may be concluded that the CP method is more suitable than the GL method for CoR estimation when RoM is limited and CoR location is perturbed.

Enhancement of Magneto-Optical Kerr Effect in Annealed Granular Films of Co-Au and $Co-AlO_x$

  • Abe, Masanori;Takeda, Eishi;Kitamoto, Yoshitaka;Shirasaki, Fumio;Todoroki, Norikazu;Gorodetzky, Gad;Ohnuma, Shigehiro;Masumoto, Tasuku;Inoue, Mitsuteru
    • The Korean Journal of Ceramics
    • /
    • 제6권2호
    • /
    • pp.100-102
    • /
    • 2000
  • Co fine particles were dispersed in Au metal and $AlO_x$ amorphous matrices by vacuum evaporation and rf-sputtering, respectively, thus forming granular composite films having chemical compositions of $Co_{0.59}-Au_{0.41}$ and $Co_{0.52}/(AlO_x$)_{0.48}$. The films were annealed at 200~$500^{\circ}C$ to increase the size of the Co particles, from 30$\AA$ to 180$\AA$ in the Au matrix and 40$\AA$ to 180$\AA$ in the $AlO_x$ matrix, as revealed by X-ray diffraction analysis. The Co metal in as-deposited films have saturation magnetization equivalent to that of bulk Co, which is unchanged by the annealing, showing that the Co metal is not oxidized by the annealing. Magneto-optical Kerr rotation measured at $\lambda$=400-900nm for the $Co_{0.59}-Au_{0.41}$ film as deposited is larger than that calculated for the composition. The rotation increases as the film is annealed at $200^{\circ}C$ and $300^{\circ}C$, approaching to that of bulk Co. The Kerr rotation for the $Co_{0.52}-(AlO_x)_{0.48}$ film as deposited is smaller than that calculated for the composition based on Bruggeman effective medium theory. However, the rotation increases much, exceeding the rotation of the bulk Co as annealed at $300^{\circ}C$ and $400^{\circ}C$. As a possible origin of the marked magneto-optical enhancement a weak localization of light in granular structure is suggested.

  • PDF

Presampled MTF 기법에서 Slant Target의 다양한 각도에 대한 함수 Fitting이 적용된 MTF 측정기법에 관한 연구 (Study of MTF Measure That Adopts a Fitting Curve for the Variable Angle of a Slant Target in Presampled MTF)

  • 최시연;김정환;공현배;김동환;백경훈;박인구;전효원;이기남
    • 한국광학회지
    • /
    • 제33권6호
    • /
    • pp.310-316
    • /
    • 2022
  • Presampled 변조전달함수(MTF) 측정에서 slant 표적각도 변화에 따라 MTF 결과의 차이가 있음을 확인하였고, 표적각도 변화에 대한 오차를 줄이기 위하여 획득한 edge spread function 그래프를 fitting하여 측정값의 오차를 줄일 수 있는 측정기법을 연구하였다. Presampled MTF 방법의 특성상 표적이 회전함에 따라 투영되는 공간주파수의 강도분포는 표적의 회전각도에 따라 변화하며, 이로 인하여 MTF 차이가 발생함을 확인하였다. 이 연구에서는 획득한 영상의 1개의 열에 대해서만 fitting을 한 후 MTF를 계산하였다. Fitting을 이용한 계산은 기존의 presampled MTF 방법과 비교하여 표적 회전에 따른 오차가 줄어듬을 확인하였다. 이 방법은 MTF를 이용한 자동 초점 등 다양한 각도의 표적에 응용이 가능할 것으로 기대된다.

A Rotation Invariant Image Retrieval with Local Features

  • You, Hee-Jun;Shin, Dae-Kyu;Kim, Dong-Hoon;Kim, Hyun-Sool;Park, Sang-Hui
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권3호
    • /
    • pp.332-338
    • /
    • 2003
  • Content-based image retrieval is the research of images from database, that are visually similar to given image examples. Gabor functions and Gabor filters are regarded as excellent methods for feature extraction and texture segmentation. However, they have a disadvantage not to perform well in case of a rotated image because of its direction-oriented filter. This paper proposes a method of extracting local texture features from blocks with central interest points detected in an image and a rotation invariant Gabor wavelet filter. We also propose a method of comparing pattern histograms of features classified by VQ (Vector Quantization) among images.

높은 Prandtl 수 유체에서 축회전이 열모세관 유동의 진동에 미치는 영향 (Effect of axial rotation on oscillatory thermocapillary flow in half-zone of high Prandtl number fluid)

  • 전승원;이규정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2248-2253
    • /
    • 2008
  • A numerical study on oscillatory thermocapillary flow in half-zone has performed to understand the effect of axial rotation. 2d unsteady code is developed to observe the onset of oscillation. 2cs Silicone oil with Prandtl number of 26.5 is used as a working fluid. The critical temperature difference at onset of oscillation is investigated under the different aspect ratios and rotation modes. It is shown that the onset of oscillation is delayed when aspect ratio reduces and rotating speed increases. The oscillatory flow is strongly reduced under top rotation and co-rotation modes, while it is augmented under bottom rotation and counter-rotation modes. It is thought that interaction between return flow and bottom wall is important to explain the oscillatory flow.

  • PDF