• 제목/요약/키워드: co-cycle

검색결과 1,786건 처리시간 0.027초

가스화 복합화력발전 플랜트에서 CO2제거가 성능에 미치는 영향 해석 (Analysis of the Influence of CO2 Capture on the Performance of IGCC Plants)

  • 차규상;김영식;이종준;김동섭;손정락;주용진
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.9-16
    • /
    • 2010
  • In the power generation industry, various efforts are needed to cope with tightening regulation on carbon dioxide emission. Integrated gasification combined cycle (IGCC) is a relatively environmentally friendly power generation method using coal. Moreover, pre-combustion $CO_2$ capture is possible in the IGCC system. Therefore, much effort is being made to develop advanced IGCC systems. However, removal of $CO_2$ prior to the gas turbine may affect the system performance and operation because the fuel flow, which is supplied to the gas turbine, is reduced in comparison with normal IGCC plants. This study predicts, through a parametric analysis, system performances of both an IGCC plant using normal syngas and a plant with $CO_2$ capture. Performance characteristics are compared and influence of $CO_2$ capture is discussed. By removing $CO_2$ from the syngas, the heating value of the fuel increases, and thus the required fuel flow to the gas turbine is reduced. The resulting reduction in turbine flow lowers the compressor pressure ratio, which alleviates the compressor surge problem. The performance of the bottoming cycle is not influenced much.

LCA를 통한 도시 고형 페기물의 환경부하평가 (Environmental Load Assessment of Municipal Solid Waste using LCA)

  • 박정한;;;이병인
    • 한국환경과학회지
    • /
    • 제12권6호
    • /
    • pp.643-650
    • /
    • 2003
  • We analyzed the amount of environmental loads, and the amount of energy consumption through life cycle assessment from a discharge stage to the ultimate disposal to municipal solid waste in Seoul. We carried out inventory analysis of the amount of environmental loads that made the object range collection, intermediate treatment, and the final treatment, and took into consideration each stage exceptions CO$_2$ and NOx , the amount of SOx discharge, and energy consumption. We applied the data of an object model, and acquisition processed the scale of an object model suitably and applied to it to difficult data using the data of the Yokohama City incineration plant in Japan. The amount of environmental loads per Iton of municipal waste were analyzed CO$_2$ 0.4C-ton, SOx 0.4kg and NOx 0.8kg. Moreover, the amount of energy consumption which is 2.4Gcal was computed.

Cycle Simulation에 의한 가솔린기관의 성능과 배출물 예측 (The prediction of performance and emissions of a spark ignition engine by cycle simulation)

  • 이종원;정진은
    • 오토저널
    • /
    • 제5권2호
    • /
    • pp.48-55
    • /
    • 1983
  • The prediction of performance and emissions is presented for a spark ignition engine. a two zone, zero-dimensional model was employed which included thermodynamics, combustion and hear transfer, and a kinetic model employed for NOx. The model was used to analyze the processes of compression, combustion and expansion. Cylinder pressures and temperatures were calculated as a function of crankangle as well as engine performance and emissions. Predictions made with the simulation were compared with experimental data from a four cylinder spark ignition engine. Calculated pressures and, Co and Co$_{2}$ concentrations showed acceptable quantitative agreement with data. But calculated No concentrations were slightly different. A parametric study of the effect of variations in speed, combustion duration and spark timing was carried out. This simulation can be useful for design of spark ignition engines.

  • PDF

Amentoflavone Acts as a Radioprotector for Irradiated v79 Cells by Regulating Reactive Oxygen Species (ROS), Cell Cycle and Mitochondrial Mass

  • Xu, Ping;Jiang, En-Jin;Wen, Si-Yuan;Lu, Dan-Dan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7521-7526
    • /
    • 2014
  • Radioprotective effects of amentoflavone were investigated by examining cell viability, apoptosis, cell cycling concentrations of intracellular ROS (reactive oxygen species), and relative mitochondrial mass by flow cytometry after $^{60}Co$ irradiation. Pretreatment with amentoflavone 24 hours prior to 8 Gy $^{60}Co$ ${\gamma}$-ray irradiation significantly inhibited apoptosis, promoted the G2 phase, decreased the concentration of ROS and mitochondrial mass. These results collectively indicate that amentoflavone is an effective radioprotective agent.

Fatigue Evaluation on the Inside Surface of Reactor Coolant Pump Casing Weld

  • Kim, Seung-Tae;Park, Ki-Sung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.795-801
    • /
    • 1998
  • Metallic fatigue of Pressurized Water Reactor(PWR) materials is a generic safety issue for commercial nuclear power plants. It is very important to obtain the fatigue usage factor for component integrity and life extension. In this paper, fatigue usage was obtained at the inside surface of Kori unit 2, 3 and 4 RCP casing weld, based on the design transient. And it was intended to establish the procedure and the detailed method of fatigue evaluation in accordance with ASME Section III Code. According to this code rule, two methods to determine the stress cycle and the number of cycles could be applied. One method is the superposition of cycles of various design transients and the other is based on the assumption that a stress cycle correspond to only one design transient. Both method showed almost same fatigue usage in the RCP casing weld.

  • PDF

R-245fa 및 NOVEC 649 작동유체에 따른 ORC 시스템 성능 변화 (ORC System Performance Analysis upon R-245fa and Novec 649)

  • 장홍순;한영섭;송영길;김성현
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.17-23
    • /
    • 2016
  • A test unit for Organic Rankine Cycle (ORC) power generation system was developed and experimentally reviewed the performance of the ORC system. Two different organic fluids (R-245fa & Novec 649) were tested as working fluids for the system. System behavior was measured and analyzed along with the variables, such as temperature, pressure, rpm and shaft power. It is one of the findings that Novec 649 fluid is to be less pressurized than R-245fa in order to up to the heat source (boiler) capacity, that limits the experiment as high as 2 kW in shaft power.

스파아크 점화기관의 사이클 시뮬레이션과 실험적 방법에 의한 성능, 배출가스, EGR효과의 예측에 관한 연구 (The prediction of performance, exhaust emissions and EGR effect of a spark ignition engine by cycle simmulation and experimental method)

  • 정용일;성낙원
    • 오토저널
    • /
    • 제8권2호
    • /
    • pp.31-42
    • /
    • 1986
  • The prediction of performance, exhaust emissions and EGR effect is made by the SI engine cycle simulation. In this simulation several models are employed - two zome, thermodynamic combustion, mass fraction burned, heat transfer, chemical equilibrium, chemical kinetics for NOx, laminar flame speed for ignition delay. The chemical species in burned gas considered are 13 species-CO$_{2}$, CO, $O_{2}$, H$_{2}$O, H$_{2}$,OH, H, O, N$_{2}$, NO$_{2}$, N, Ar - and the cylinder pressure, burned and unburned zone temperature and composition of gas are calculated at each crank angle through the compression, ignition delay, combustion and expansion process. To check the validity of the model, experimental study is done for measuring emissions, combustion pressure and engine output. The predicted values for pressure and emissions show qualitative agreement with the measured data and the EGR effect also shows similar tendency.

  • PDF

심냉 증류를 통한 전자급 고순도 이산화탄소의 분리 공정에 대한 전산 모사 연구 (A Computer Simulation Study on the Separation Process for Electronic Grade, Highly Pure Carbon Dioxide through a Cryogenic Distillation)

  • 박일수;문흥만;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.83-89
    • /
    • 2023
  • In this study, a computer simulation work has been performed for the separation of electronic grade highly pure carbon dioxide more than 7 N purity through a cryogenic distillation process. For the cold utility as a cooling medium for a condenser of the cryogenic distillation column, propylene was utilized as a refrigerant in the vapor-recompression refrigeration cycle. Through this work, it was concluded that the cryogenic distillation column with two stage compression and refrigeration cycle were essential to obtain a highly-pure liquefied CO2.

Radiation and Decommissioning Laboratory, an R&D Center for the Back-end Cycle of Nuclear Power Plants

  • Cheon-Woo Kim
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.419-425
    • /
    • 2023
  • The Radiation and Decommissioning Laboratory of Central Research Institute (CRI) of Korea Hydro and Nuclear Power Co. (KHNP) performs research to technically support the effective management of radiological hazards to avoid risks to civilians, the workers, and the environment from the radiological risks. The laboratory mainly consists of three technical groups: decommissioning and SF technology group, radiation and chemistry group, and radwaste and environment group. The groups carry out various R&D such as decommissioning, spent fuel management, radiation protection, water chemistry management, and radioactive waste management. The laboratory also technically supports the calibration of radiometric instruments as a Korea Laboratory Accreditation Scheme (KOLAS), approval for decommissioning, guidance for radioactive waste management, state-of-the-art technology evaluations, and technology transfer.