• 제목/요약/키워드: co-cycle

검색결과 1,786건 처리시간 0.025초

담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석 (Analysis of combined cycle for desalination process and $CO_2$ refrigeration system)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

Recent trends of supercritical CO2 Brayton cycle: Bibliometric analysis and research review

  • Yu, Aofang;Su, Wen;Lin, Xinxing;Zhou, Naijun
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.699-714
    • /
    • 2021
  • Supercritical CO2 (S-CO2) Brayton cycle has been applied to various heat sources in recent decades, owing to the characteristics of compact structure and high efficiency. Understanding the research development in this emerging research field is crucial for future study. Thus, a bibliometric approach is employed to analyze the scientific publications of S-CO2 cycle field from 2000 to 2019. In Scopus database, there were totally 724 publications from 1378 authors and 543 institutes, which were distributed over 55 countries. Based on the software-BibExcel, these publications were analyzed from various aspects, such as major research areas, affiliations and keyword occurrence frequency. Furthermore, parameters such as citations, hot articles were also employed to evaluate the research output of productive countries, institutes and authors. The analysis showed that each paper has been cited 13.39 times averagely. United States was identified as the leading country in S-CO2 research followed by China and South Korea. Based on the contents of publications, existing researches on S-CO2 are briefly reviewed from the five aspects, namely application, cycle configurations and modeling, CO2-based mixtures, system components, and experiments. Future development is suggested to accelerate the commercialization of S-CO2 power system.

내부열교환기 및 전자팽창장치를 적용한 가변속 이산화탄소 사이클의 냉방성능에 관한 실험적 연구 (Experimental Study on the Cooling Performance of a Variable Speed $CO_2$ Cycle with Internal Heat Exchanger and Electronic Expansion Valve)

  • 조홍현;류창기;김용찬
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.209-215
    • /
    • 2005
  • Since a transcritical $CO_2$ cycle shows lower performance than conventional air conditioners in the cooling mode operation, it is required to enhance the performance of the $CO_2$ cycle by applying advanced technologies and optimizing components. In this study, the cooling performance of a $CO_2$ system measured by varying refrigerant charge amount, compressor frequency, EEV opening and length of internal heat exchanger. As a result, the cooling COP of the basic system without internal heat exchanger was 2.1. The cooling performance of the modified cycle applying internal heat exchanger improved by $4-9\%$ over the basic cycle.

Life Cycle Assessment(LCA)를 도입(導入)한 오니처리(汚泥處理)시스템의 평가(評價) (Life Cycle Assessment (LCA) on Sludge Treatment System)

  • 황용우;권봉기;유성호
    • 상하수도학회지
    • /
    • 제11권2호
    • /
    • pp.50-64
    • /
    • 1997
  • Life cycle assessment (LCA) on total sewage sludge treatment system from thickening to incineration and melting was performed for estimating global environmental impact as $CO_2$. In general, the life cycles of actual treatment facilities consist of construction, operation and dismantlement. In this study, the amount of $CO_2$ produced from both whole and each life cycle step of currently used unit sludge treatment processes were calculated by inventory analysis. In addition, in the all processes investigated in this study, individual $CO_2$ production unit (CPU), i.e. total produced $CO_2$ by treating a unit weight of sludge was also calculated. By using the CPU matrix of the unit processes, it was possible to simulate the $CO_2$ production for any type of complex-system as well as to trace a dominant cause of $CO_2$ production in each process. Four selected alternatives examined here, each involve the same disposal way but differ substantially in the $CO_2$ exhaust.

  • PDF

초고층 공동주택 세대내 개보수 주기에 따른 이산화탄소 배출량 연구 (A Study on Quantity of CO2 Emission about Remodeling Cycle at High-rise Apartment housing)

  • 김다유;강승이;제해성
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.75-80
    • /
    • 2010
  • The goal of this study is to figure out the remodeling cycle at high-rise apartment housing and to analysis on quantity of $CO_2$ emission about remodeling cycle. The process of research is as follow; 1) Estimate the remodeling cycle through survey targeting residents at high-rise apartment building. 2) Simulate conditions on the high-rise apartment housing. 3) Calculate quantity of energy consumption and $CO_2$ emission 4) Derive elements that are on high level of environmental load evaluation. The main results of this study is as follow; 1) The cycle of finishing such as wallpaper is shorter than the cycle of building equipment such as elements in a toilet. 2) According to result of calculating $CO_2$ emission, fabric wallpaper and mortar are main factors that impact on the environment. The results is important to show reference points on quantitative measuring evaluation for the environmental-friendly extent.

혁신주기, 투자주기 그리고 경기변동에 관한 실증분석 (An Empirical Analysis on the Relationship among Innovation Cycle, Investment Cycle and Business Cycle in Frequency Domain)

  • 조상섭;이장우
    • 기술혁신학회지
    • /
    • 제5권2호
    • /
    • pp.129-140
    • /
    • 2002
  • This study is try to do the empirical tests on the relationship among innovation cycle, investment cycle, and business cycle suggested in recent economic growth models. We apply co-spectra analysis to estimate dynamic correlations in the extraction HP filtered variables and first difference filtered variables in our data set. Our empirical results are; (i) an existing asynchronization between innovation cycle and investment cycle, (ii) in the long frequency, an existing positive correlation between innovation cycle and business cycle, (iii) in the short frequency, however, a finding the high negative correlation between the two cycle. Our empirical findings support the recent growth through cycle models and suggest some economic policy implementations for economic stabilization during a severe business cycle.

  • PDF

Life Cycle Assessment (LCA)를 적용한 오니집약처리(汚泥集約處理)의 평가(評價) (Life Cycle Assessment (LCA) on Intensive Sludge Treatment System)

  • 황용우;권봉기;서성원
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.65-74
    • /
    • 1998
  • Life cycle assessment (LCA) on two different sludge treatment systems, on-site treatment and pipe-collected intensive treatment was performed to estimate the environmental impact in the aspect of global warming effect. As a main parameter of the estimation, $CO_2$ was chosen and quantified through the whole life cycle of the treatment systems including construction, operation and dismantlement. In this study, the changes of $CO_2$ production unit (CPU) by up-scaling n currently used sludge treatment processes were also calculated. As the result, a larger amount of $CO_2$ was exhausted from the construction step of intensive treatment system than that of on-site treatment system, because an additional pipe-collection system was needed in intensive treatment system. However, the total amount of $CO_2$ exhausted from whole life cycle including not only construction and dismantlement but also 15 year-operation and maintenance was reduced by appling intensive treatment.

  • PDF

이산화탄소를 이용한 초월임계사이클의 성능해석 (Analysis on the Performance of a Transcritical Cycle Using Carbon Dioxide)

  • 김성구;김민수
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.471-479
    • /
    • 2003
  • A simulation on the performance of a transcritical $CO_2$ heat pump system is carried out to investigate its characteristics for various operating conditions. Cycle simulation models are established for a steady-state simulation and are verified by comparing experimental data. Based on correlations and methods available in the literature, the processes in individual components of the transcritical cycle are simulated to analyze the performance of $CO_2$ transcritical heat pump system. The simulation models are good enough to predict the performance of a $CO_2$ transcritical cycle. Simulation results are provided to show the relative effects when varying the size of internal heat exchanger and the discharge pressure of a compressor.

2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구 (Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle)

  • 류창기;이호성;김용찬;조흥현;조성욱
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

로터리 압축기용 Short-Cycle 신뢰성 시험장치 제안 (Suggestion of Test Apparatus for Reliability Evaluation of a Rotary Compressor with a Short-Cycle)

  • 이태구;이상재;김현우;김상현;이재헌;유호선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.584-589
    • /
    • 2006
  • In this paper, a test apparatus for reliability evaluation of a rotary compressor has been suggested with a short-cycle concept. $CO_2$ refrigerant is adopted for this cycle to avoid phase change during cycle operation. Evaporator is not necessary in short-cycle. Utilizing a short-cycle, the test apparatus was built on the purpose of evaluating the reliability of each rotary compressor on the conveyer belt of the factory. The primary validation of the test apparatus is discussed by analyzing the experimental heat balance data. Additional validation was performed through the overload continuous operation test where the wear rate of the $CO_2$ short-cycle was found to similar to that of the R22 normal-cycle. The reliability evaluation test apparatus with a short-cycle in present investigation was found simple and efficient in the view of reducing sample numbers, costs, and test time in analyzing the reliability of rotary compressors.

  • PDF