• 제목/요약/키워드: co-authors

검색결과 449건 처리시간 0.03초

제사용수의 경도성분과 해서촉진제와의 관계 (Relationship of Hardness Components in Filature Water with Reelability Aid Reagent)

  • 최병희;이용우
    • 한국잠사곤충학회지
    • /
    • 제13권1호
    • /
    • pp.49-59
    • /
    • 1971
  • This experiment was conducted, how making use of "Seracol 100", a kind of nonionic surface active reagent, during cocoon cooking and silk reeling process which is mainly used in Korea and developed by one of the authors since 1965. Main purpose of the experiment is to investigate the influence of the activity of the reelability aid reagent on various degree of hardness component and various salts which are contained in filature water being used by silk factories now. Specifically, it was tried to determine the effects of the reelability aid reagent added to each sample water of artificially differentiated the degree of hardness component upon sericin solubility. Some of the major findings are summarized as follows. 1. "Seracol 100", with below 5$^{\circ}$dH water, increased sericin solubility in each sample water, but above $10^{\circ}$dH the effect of it shows a significant relationship with the different degree of hardness component. Besides the component (MgCO$_3$)$_4$ㆍMg(OH)$_2$, generally, the higher the degree of hardness in the water, the less the amount of desolved sericin in the water showed. There is little or no difference between 1000 times diluted "Seracol 100" water and 2000 times diluted "Seracol 100" water in terms of sericin solubility. 2. The different kind of degree of hardness component shows a significant relationship with sericin solubility, In case use of "Seracol 100", Mg hardness component affected on the sericin solubility more than Ca hardness. But in the control, contrary to this, that is Ca hardness component did more than Mg hardness, 3. The different kind of salts in degree of hardness component show a significant relationship with sericin solubility. In the control water, nitrate is the greatest among salts affecting on sericin solubility, next chloride and sulfate are in order. In case of "Seracol 100" water, chloride is the least among salts, below $10^{\circ}$dH, next sulfate and nitrate are in order, and above 15$^{\circ}$dH, next nitrate and sulfate are in order. 4. In case of "Seracol 100" water, the more contained heavy metal salts (Fe, Al, Cu, Mn) in the water, the less sericin solubility showed. It is found that there is little or no difference among other salts in terms of sericin solubility. But alkaline metal salt remarkably increased sericin solubility. 5. In case of "Seracol 100" water, tinting of the water was affected by Ca salts more than by Mg salts. Among other salts, only Al and Fe affected on the tinting of the water, specifically, in view of the fact that "Seracol 100" water increase the tinting of Fe salt water, but decrease the tinting of raw silk. It is thought that "Seracol 100" deter Fe$^{+2}$ from absorbing to raw silk by deteriorating the activity of Fe$^{+2}$ . 6. "Seracol 100" have the effect on osmosis of the water, After treatment until 2hrs the osmosis of 1000 times diluted "Seracol 100" water is the greatest, next orders are 2000 times diluted "Seracol 100" and control. From 2 hrs to 6 hrs the osmosis of 2000 times diluted water is the greatest, next orders are 1000 times diluted water and control. After 6 hrs the osmosis of the water is the same order as above. 7. In view of tile fact that "Seracol 100" have the effect to control the degree of hardness during the treatment of cocoon layer in the water, it is thought that, in varying degree of hardness in the water, there is a significant relationship between "Seracol 100" and degree of hardness components in cocoon layer.

  • PDF

Suspension Laryngoscope 하에 후두미세 수술을 시행한 53명에 대한 임상통계학적 고찰 (Clinicostatistical Analysis for 53 Cases which were performed Microlaryngeal Surgery under Suspension Laryngoscope)

  • 전하동;최인환;추광철;김선곤
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1979년도 제13차 학술대회 연제순서 및 초록
    • /
    • pp.6.3-7
    • /
    • 1979
  • Scalco, Shimpson & Tabb가 lynch suspension laryngoscope를 이용하여 후두의 용종 및 병변의 치료목적으로 최초로 microsurgery에 성공한 후 Klein-sasser의 후두 microsurgery에 대한 신기술의 보고 및 체계화는 근래 20년 동안 발전된 microlaryngeal surgery에 많은 기여를 하였다. 최근 간접후두경하의 조작보다 이의 사용이 증가하는 경향이 있으며 이에 저자들은 1972넌 5월부터 1979년 4월까지 한양대학병원 이비인후과에서 suspension laryngoscope를 시행한 53명 (75례)에 대하여 다음과 같은 지견을 얻었기에 보고하는 바이다. 1) 성별로는 남녀 1.3 : 1로 남자가 많았다. 2) 연령분포는 30대 14명(26.4%), 20대 10명 (18.7%), 50대 9명 (17%), 60대 7명 (13.234), 10세 미만 6명 (11.3%)의 순이고 최저 2세, 최고 74세였다. 3) 증상별로는 애성 48명 (90.6%), 호흡곤란 16명(30.5%), sore throat 8명 (15.1%)순이고 그외 이물감, 연하곤란 객담 구강건조감 인후불편 decannulation 곤란증 stridovr 기침등이 있었다. 4) 증상발현후 내원까지의 기간은 1∼6개월 11명(20.8%), 6개월∼l년 10명(18.9%), 1개월이하 8(15.1%), 2∼3년과 5∼10년 5명(9.4%), 1∼2년과 4∼5년 4명 (7.6%), 3∼4년과 10년이상이 3명(5.7%)의 순이고 최단기간은 후두마비에 의한 호흡곤란의 2일이었다. 5) 임상적 진단은 용종 18명(34%), 결절 12명(22.6%), 유두종 9명(17%), 종양 7명(13.2%), intubation granuloma 3명(5.7%)의 순이고 그외 decannulation 곤란증과 동반된 후두 협착, 성대마비, 혈종등이 있었다. 6) 48명의 병리조직학적 결과는 용종 17명 (35.4%), 유두종 11명(23%), 결절 9명(8.9%), 악성종양 3명(6.3%), 만성염증 2명(4.2%), 그외 hyperkeratosis, mucous retension cyst, 농양과 동반된 결절, 육아종, 혈종, 확인을 할 수 없던 것이 각각 1례씩 있다. 7) 종양의심환자 7명중 악성종양 3명, 유두종 1명, 농양과 동반된 결절 1명, 만성염증 1명 및 확인불가능이 1명이었다. 8) 반복시술한 경우는 6명이었고 기술적 곤란이 1례 유두종의 재발 5례였으며 최고 10회도 있었다. 9)병변의 부위는 결절 및 용종의 26명중 양측 15례(60%), 좌측 5례(19%), 우측 3례(12%), 전연합까지 침범된 경우 3례(12%)며 유두종 11명의 경우 전후두침범 7례(63.6%), 일측성대침범 3례(27.3%), 후두외 까지의 침범 1례(9.1%)였다.

  • PDF

고덕원 국보 동조아미타여래좌상의 표면에 생성한 부식생성물의 해석 (Analysis Corrosion Products Formed on the Great Buddha Image of Kotokuin Temple in Kamakura)

  • 송전사랑;청목번부;강대일
    • 보존과학연구
    • /
    • 통권17호
    • /
    • pp.161-182
    • /
    • 1996
  • 최근 환경 오염의 영향으로 문화재가 급속히 손상되고 있다. 이에 일본 동경국립문화재연구소에서는 1992년부터 일본 겸창시의 고덕원, 귀원원, 학강팔번궁, 도근현의 일어기신사, 내량시의 동대사 등에 환경 오염 관측 스테이션을 설치하여 조사하고 있다. 본고는 1996년 3월 일본 동경국립문화재연구소에서 발행된 보존과학 제35호에 실린 송전사랑, 청목번부씨의 “고덕원 국보 동조아미타여래좌상의 표면에 생성한 부식생성물의 해석”논문을 저자의 호의에 의해 번역하였다.

  • PDF

소아간질의 임상적 관찰 (Clinical Investigation of Childhood Epilepsy)

  • 문한구;박용훈
    • Journal of Yeungnam Medical Science
    • /
    • 제2권1호
    • /
    • pp.103-111
    • /
    • 1985
  • 저자들은 1983년 5월부터 1985년 11월까지 만 30개월간 본원 소아과를 통해 진료받은 100명의 소아간질환아를 대상으로 관찰한 결과 다음과 같은 성적을 얻었다. 1. 남녀별 발생빈도는 1.2:1로 남아에서 약간 많았다. 2. 경련발생 연령은 6개월 미만이 13예(12.6%), 6개월~3세군이 34예(33.0%), 3~5세군이 16예(15.5%), 5~10세군이 24예(23.3%), 10~15세군이 16예 (15.5%)였다. 3. 간질경련 양상은 generalized tonic-clonic, tonic, clonic seizure가 49.5%, 간대성 근경련이 5.8%, 비전형 소발작이 5.8%, 이완성발작이 1%였고, simple P.S.가 7.8%, complex P.S.가 3.9%, simple P.S. $\overline{c}$ 2nd G.이 17.5%, complex P.S. $\overline{c}$ 2nd G.이 2.9%, 미분류가 5.8%였다. 4. 간질의 원인으로 추정이 가능했던 경우가 17예(16.5%)였는데 주산기 저산소증(4.9%), 뇌막염(3.9%), 미숙아분만(1.9%) 등이 많은 원인이었다. 5. 간질과 동반된 질환은 30예(29%)에서 보였는데 지능장애, 과다행동증, 운동발달지연, 뇌성마비 등이 많았다. 6. 42예에서 행한 뇌 전산화단층촬영에서 14예의 이상소견을 보였는데 뇌 위축이 6예, 뇌경색이 3예, 수두증 및 뇌부종소견이 각각 2 예씩 나타났다.

  • PDF

발명영재교육에 관한 학술연구 동향 분석 (An Analysis of the Trends in Academic Research on Invention Gifted Education)

  • 이민혜
    • 국제교류와 융합교육
    • /
    • 제3권1호
    • /
    • pp.1-28
    • /
    • 2023
  • 이 연구에서는 발명영재교육의 국내 연구들의 양적 경향성을 살펴보고 이들 연구분석에서 내재적 의미와 연결속성을 파악하여 향후 발전 방안을 모색하기 위한 기초자료를 제공하고자 수행하였다. 이를 위하여 한국학술연구정보원(RISS)에서 '발명영재교육' 으로 논문을 검색하여 등재후보지 이상의 국내 학술논문 97편을 최종 선정하고, 발행년도, 저자구성, 연구자 소속과 소재지역, 발행 학술지 등 연구일반에 관한 SPSS로 기술적 통계분석을 수행하고, 학술논문의 키워드를 이용하여 상위출현빈도, N-gram, 연결·매개중심성을 살펴보았다. 발명영재교육 학술논문으로 확인된 2007년 이후 증가세를 보이던 추세가 제3차 영재교육진흥종합계획 시기를 정점으로 이후 다시 감소세를 나타냈다. 저자 특성를 기술적 통계분석한 결과, 논문 절반이 공동으로 발표되었고 그 다음으로 다수, 단독의 저자구성을 보이고 있었다. 단독으로 발행된 논문은 연구자 소속이 대학, 연구소, 초등학교, 중학교 소속으로 확인되었고, 협력적 논문은 신진 연구자와 전문 연구자가 협력하는 연구, 전문 연구자 간 협력 연구가 다수였으며, 신진 연구자 간 협력적 연구는 1편에 그쳤다. 발명영재교육 논문이 발표된 지역과 학술지를 살펴볼 때, 일부 지역이나 학술지에 집중되어 있었고, 편차가 매우 크게 나타났다. 학술논문 키워드를 이용한 언어네트워크 분석 결과 상위 출현성을 보인 의미 있는 키워드는 창의, 프로그램 등이 확인되었고, 동출현성이 높은 키워드 쌍은 발명영재-창의이었다. 상위의 연결중심성 키워드는 창의, 문제해결·개발·기업 등이 다른 연구주제로 확장하기 위한 중개자 역할을 하며 다양한 주제로 확장 가능한 연구주제로 작용하고 있었다. 매개중심성의 경우 창의, 창의적, 프로그램, 효과 등이 높은 매개중심성을 보여 다른 키워드를 상호매개하거나 중재시키는 역할을 하는 중요한 키워드임을 알 수 있었다. 이러한 연구 결과를 통해 발명영재교육의 발전을 위한 국가정책적 대책이 마련될 필요가 있으며, 영재교육에 대한 사회적 책무성을 높이는 한편, 교사의 전문성을 신장할 수 있는 발명생태문화를 조성할 필요성을 제기하였다.

『대순사상논총』의 연구 동향에 관한 연구- 『대순사상논총』 1집-25집(1996~2015) - (Research Trends in The Journal of Daesoon Academy of Sciences : 『The Journal of Daesoon』 Vol.1-Vol.25 (1996~2015))

  • 장인호
    • 대순사상논총
    • /
    • 제27집
    • /
    • pp.201-243
    • /
    • 2016
  • 창간호인 1996년 1집부터 최근 2015년 25집까지(총26집) 『대순사상논총』에 게재된 학술논문 총358편을 대상으로 연구 동향을 분석하고 발전방향을 위한 제언을 하였다. 우선, 『대순사상논총』지의 한국연구재단 등재를 위한 조건에서는 가장 중요한 학술지의 규칙성 및 정시성 등에서 자격에 미치지 못했다. 그리고 계량서지학적 분석을 보면, 학술지의 논문 수가 점차 줄어들고 있으며, 발행사항, 참고문헌 등 모든 면에서 원칙 및 규칙 등 일관성이 전혀 보이지 않았다. 그리고 최근 들어 다양한 저자가 참여하고 있지만, 공동저자 논문 비율이 너무 낮았다. 학술지의 확대를 위해서는 대순사상에 대한 전문 연구자를 확보하는 것도 중요하지만 다양한 소속기관 및 연구자들과 교류를 통해 연구 주제의 다양화를 시도하는 것이 필요하다. 『대순사상논총』의 발전을 위한 제언을 정리해보고자 한다. 첫째, 학술지 발행주기의 규칙성 및 정시성을 위해 『대순사상논총』은 연2회 발행과 12편에서 15편 정도의 논문이 게재되는 것이 좋을것 같다. 둘째, 기본적인 검색이 가능하도록 데이터베이스 구축이 이루어져야 한다. 셋째, 연구자들의 논문 공유를 위해서는 키워드와 초록은 한글과 영문으로 동시에 작성되어야 한다. 넷째, 지역적 분포도를 고려하고 다양하고 우수한 편집위원이 구성될 수 있도록 해야 한다. 다섯째, 대순사상의 특성을 주로 반영한 핵심영역과 대순사상과 융합을 할 수 있는 주변영역으로 적절이 배분되어야 한다. 여섯째, 논문의 첫 장에 중요한 서지사항이 모든 들어가는 것이 정보를 전달하는 면에서 필요하다. 일곱째, 권호 또는 Vol. no로 변환을 시도하고 발행 연월일을 명확히 해야 할 필요가 있다.

PDGF-BB에 의한 치주인대세포활성에 대한 TGF-{\beta}의 효과 (The Effect of TGF-{\beta}_1 on Cellular Activity of Periodontal Ligament Cells activated by PDGF-BB)

  • 백상철;박진우;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.457-473
    • /
    • 2002
  • 이 연구는 배양된 치주인대세포에 TGF(Transforming growth factor)-${\beta}_1$과 PDGF(Plateletderived growth factor)-BB를 농도별로 혼합 주입해서 세포의 증식능, 단백질 및 교원질 합성능을 측정해 봄으로서 TGF-${\beta}_1$ 이 치주인대세포의 중식과 활성에 대한 PDGF-BB의 효과를 상승시킬 수 있은지 알아보고자 본 실험을 실시하였다. 교정치료를 위해 내원한 환자로 부터 건강한 제일소구치를 발거하여 치주인대세포률 분리, 배양하여 TGF-${\beta}_1$과 PDGF-BB를 동시에 주입한 군과 TGF-${\beta}_1$를 4, 24시간 전처리 배양한 군과 나누어 실험하였다. TGF-${\beta}_1$, PDGF-BB를 주입하지 않은군을 대조군으로 하여 DNA 합성능, 총단백질과 교원질 합성능을 측정하여 다음과 같은 결과를 얻었다. 치주인대세포에 TGF-${\beta}_1$과 PDGF-BB을 동시 주입하였을 때 DNA 합성능의 효과는 대조군에 비해 모든 군에서 증가된 양상을 보였으며 1ng/ml PDGF-BB 투여군에 비해 10ng/ml PDGF-BB 투여군에서 증가 양상이 높았고 PDGF-BB 단독 투여군보다 TGF-${\beta}_1$병용 투여군에서 DNA 합성능이 증가된 양상을 나타내었으며 5ng/ml TGF-${\beta}_1$과 10ng/ml PDGF-BB 투여군에서 가장 높은 증가 양상을 보였다. TGF-${\beta}_1$ 4시간과 24시간 전처리 배양군 양군 공히 lng/ml PDGF-BB 투여군을 제외한 모든 군에서 대조군에 비해 증가된 양상을 보였으며 lng/ml PDGF-BB 투여군에 비해 10ng/ml PDGF-BB 투여군에서 증가 양상이 더 높았고 PDGF-BB 단독 투여군보다 TGF-${\beta}_1$ 전 처리군에서 DNA 합성능이 증가된 양상을 나타내 였으며 5ng/ml TGF-${\beta}_1$ 전 처리 후 10ng/ml PDGF-BB 투여군에서 가장 높은 증가 양상을 보였다. 치주인대세포에 TGF-${\beta}_1$과 PDGF-BB을 동시 주입하였을 때 총단백질합성량은 대조군에 비해 모든 군에서 증가된 양상을 보였으며 lng/ml PDGF-BB 투여군에 비해 10ng/ml PDGF-BB 투여군에서 증가 양상이 더 높게 나타났다. PDGF-BB 단독 투여군보다 TGF-${\beta}_1$ 병용 투여군에서 총단백칠 합성양이 증가된 양상을 나타내었다. TGF-${\beta}_1$ 4과 24시간 전처리 배양군의 총단백질 합성양은 대조군에 비해 모든 군에서 증가된 양상을 보였으며 1ng/ml PDGF-BB 투여군에 비해 10ng/ml PDGF-BB 투여군에서 증가 양상이 더 높았고 TGF-${\beta}_1$ 전처리 배양군이 PDGF-BB 단독 투여군보다 총단백질 합성양이 증가된 양상을 나타내었다. TGF-111과 PDGF-BB를 동시 투여하였을 때 대조군에 비해 모든 군에서 교원질 합성능이 증가하는 경향을 나타내었으며, 비교원성단백질의 합성능은 1, 10ng/ml PDGF-BB 단독투여군을 제외하고 대조군에 비해 증가하는 경향을 보였다. 총단백질에 대한 교원질 합성의 상대적 비율 PDGF-BB 단독 투여군보다 TGF-${\beta}_1$ 병용 투여군에서 감소하는 정향을 나타내었다. TGF-${\beta}_1$ 4과 24시간 전처리 배양군의 교원질과 비교원성 단백질 합성능은 대조군에 비해 모든 군에서 교원질과 비교원성 단백질 합성능이 증가하는 경향을 나타내었으며 PDGF-BB 단독 투여군보다 TGF-${\beta}_1$ 병용 투여군에서 총단백질 합성양이 증가된 양상을 나타내었으며 그 정도는 TGF-${\beta}_1$의 농도 의존적인 양상을 보였다. 총단백질에 대한 교원질 합성의 상대적비율은 TGF-${\beta}_1$ 4,24시간전처리 배양군 모두에서 대조군에 비해 감소하는 경향을 나타내었다. 이상의 결과를 종합해 볼 때 치주인대세포에서 TGF-${\beta}_1$은 PDGF-BB의 기능을 조절하는 능력을 가지고 있으며 두 성장인자 주입시 동시주입시보다 TGF-${\beta}_1$을 전처리 해 줌으로써 PDGF-BB의 반응을 더욱 촉진시킬 수 있음을 알 수 있었다.

난소 미분화세포종의 치료 결과 (Treatment Results of Ovarian Dysgerminoma)

  • 정은지;서창옥;성진실;금기창;김귀언
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.221-228
    • /
    • 1996
  • 목적 : 난소 미분화세포종의 임상적 특징과 치료 방법, 국소 제어율, 치료 실패 양상, 생존율 등 치료 성적을 분석해 보고, 가임력을 보존하기 원하는 병기 13 환자들에서의 적절한 치료 방침을 찾아보고자 본 연구를 시행하였다. 대상 및 방법 : 1975년 1월부터 1990년 12월까지 연세 의대 신촌 세브란스병원, 연세암센터에서 진단 및 치료를 받은 34명의 난소 미분화세포종 환자를 대상으로 하였다. 이중 2예의 gonadoblastoma(46,XY)와 3예의 혼합 배세포종(mixed germ cell tumor)을 제외하고 나머지 순수 미분화세포종(pure dysgermlnoma) 환자 29예만을 연구 대상으로 하여 치료 방법에 따라 두군으로 나누어 성적을 분석하였다. 1군은 수술후 보조적 방사선치료를 받은 환자로 21예였고, 2군은 수술후 보조적 방사선치료를 하지 않은 군으로 8예였다. 대상 환자의 연령 분포는 8-39세였고 중앙치는 23세였다. 진단 시 임상 증상은 촉지되는 복부 골반부 종괴가 가장 호발하였다. 병기는 I이 23명으로 $89.3\%$로 다수를 차지하였다. 방사선치료는 병기 I, II에서는 전복부조사 20-25 Gy, 골반부에 축소하여 10-15 Gy 추가 조사하였고 종격동과 쇄골 상부의 방사선치료는 대부분 II기 이상의 진행된 병기에서 20-26 Gy 조사하였다. 환자들의 추적 관찰 중앙치는 80개월(13-201개월)이었다. 결과 : 수술후 보조적 방사선치료를 받은 환자인 1군(21예)은 전원 국소제어 및 무병 생존중이었다. 2군은 수술후 보조적 방사선치료를 하지 않은 8예인데 이중 6예에서 국소 재발지 발생하여 4예는 구제 목적의 방사선치료를 받았고 1예는 항암화학요법을 1예는 재수술만 시행 받았다. 구제 치료 결과 방사선치료를 받은 4예중 3예, 항암화학요법 받은 1예 및 재수술을 받은 1예는 완치되었으나, 1예만 암종증(carcinomatosis)으로 진행되어 방사선치료후 11개월에 사망하였다. 그러므로 29예 전체의 5년 국소 제어율 및 5년 생존율은 $96.6\%$(28/29)였다. 일측 난소에 국한된 병기 la 환자 13예 중 7예는 수술 및 수술후 방사선치료를 받았고 이들은 전원 국소제어 되어 20-201개월간(중앙치 80개월) 무병 추적 관찰 중이나, 수술로 일측 난소난 관절제술 후 방사선치료 없이 지내던 6예의 환자 중 5예에서 재발하였으나 이들 모두 방사선치료, 항암화학요법, 재수술 등의 구제치료에 성공하였다. 즉 13예의 병기 la 환자 전원이 20-201개월간 무병 생존 중이다. 결론 : 난소 미분화세포종의 치료에 있어서 수술후 보조적 방사선치료를 부가함으로 종양의 크기, 병기, 수술법에 관계없이 $100\%$ 국소 제어율 및 $100\%$ 5년 생존율을 획득하였다. 수술후 재발한 경우라도 암종증(carclnomatosis)이나 복부 이외의 장기에 원격 전이가 없다면 방사선치료, 항암화학요법 또는 재수술로 구제될 가능성이 매우 높다. 그러므로 가임력을 보존하기 원하는 병기 la 환자에서는 보존적 수술인 일측 난관난소절제술만 시행하고 추적 관찰하는 것도 치료 방법으로 고려될 수 있겠다.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF