• Title/Summary/Keyword: closer

Search Result 2,241, Processing Time 0.037 seconds

Analysis of Structure and Endurance for Cylinder-type Door Closer (실린더타입 도어클로저의 구조 및 내구해석)

  • 김민건;정구현;박찬원
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.3
    • /
    • pp.91-97
    • /
    • 2004
  • The door closer is a typical system which consists of spring and damper. The door closer is a device to close the door more slowly. The virtual prototypes of cylinder-type door closer are developed. The simulations of virtual prototype are performed to obtain the load history of the guide pin. The structural strength assessment of the guide pin is performed to verify a design safety. The fatigue life and damage of the guide pin are predicted using a FEMFAT 4.3h based on the finite element analysis.

CEO to the Rescue: Residential Proximity of Private Firm CEOs and the Evolution of Corporate Profitability

  • KIM, WOOJIN;YANG, DONG-RYUNG
    • KDI Journal of Economic Policy
    • /
    • v.38 no.4
    • /
    • pp.1-21
    • /
    • 2016
  • This paper documents how the net profit margin of private firms improves when the CEOs of the companies relocate their primary residence to be closer to the corporate headquarters. By reviewing 127 Korean non-public companies belonging to 66 private business groups, we find that the top managers move closer to the headquarters when the profitability of the firms has recently deteriorated. A one basis point decline in the margin causes CEOs to relocate their homes approximately two kilometers closer to their corporate headquarters. The profit margin rebounds after their relocation. This finding implies that physical proximity can serve as a proxy for personal commitment.

  • PDF

Priming Effects of Disaster-related TV News: Focusing on the Interactions of Geographical and Psychological Distance (재난 뉴스의 점화 효과: 지리적·심리적 거리의 상호작용을 중심으로)

  • Bu Jong, Kim;Yun Kyeung, Choi
    • Korean Journal of Culture and Social Issue
    • /
    • v.29 no.1
    • /
    • pp.53-74
    • /
    • 2023
  • The purpose of this study was to identify the priming effects of disaster-related news. Specifically, this study aimed to examine the priming effects about trauma words and neutral words according to the geographical and psychological distance from the disaster. The participants in this study were 75 college students who had not experienced the Daegu subway fire accident, and whom were not ruled out after completing the screening measure completing the screening measure the completion of questionnaires for screening. All participants conducted a lexical decision task after watching a news video about the Daegu subway fire accident. The design was a 2 (Geographical distance: close vs. distant) × 2 (Psychological distance: close vs. distant) × 2 (Priming type: trauma priming vs. neutral priming) mixed-design. The results of this study are summarized as follows: First, the group which was geographically closer to the disaster tended to revealed a largerbigger priming effect than the distant group-a trend toward significance. Second, within the psychologically closer to the disaster, group, for those who were geographically closer too, the priming effect was larger for those who were geographically closer geographically closer than for the geographically distant group. Third, the geographically closer group had a largerbigger neutral priming effect than the distant group. Fourth, the psychologically distant group had a largerbigger neutral priming effect than the close group. To sum up, this study identified that disaster news coverage may have an implicit effect on people, and this influence can change according to the geographical and psychological distance. Finally, this study discussed the limitations of the study and recommendations for further research.

Position and Force Control Based on Fuzzy Switching Algorithm

  • Jaehyun Jin;Sungho Ahn;Park, Byungsuk;Jisup Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.85.1-85
    • /
    • 2002
  • In this paper, a control strategy of position and force is proposed based on a switching algorithm. The main focus is the control of position and force in the same direction. The switching algorithm based on a fuzzy algorithm determines the weighting value of force control. First, the force control is dominant. If the position gets closer to the desire position, the weighting value of force control is closer to zero. The proposed algorithm is shown to be satisfactory to position and force control and the weighting factor is quite successful by simulation examples.

  • PDF

The effects of residential proximity on parents' mental and physical health: Parental age and the adult child's gender as moderators (세대 간 거주근접성과 부모의 정신 및 신체 건강 : 부모 연령, 성인자녀 성별의 조절효과분석)

  • Nam, Boram;Choi, Heejeong
    • Journal of Family Relations
    • /
    • v.23 no.2
    • /
    • pp.111-131
    • /
    • 2018
  • Objectives: This study examined the effects of residential proximity to adult children on the mental and physical health of middle-aged and older parents. The study also evaluated whether the parental age and gender of the adult child in closest proximity to the parent might moderate the association. Method: Data were drawn from five waves of the Korean Longitudinal Study of Aging(2006-2014). The analytic sample consisted of 7,359 parents aged 45 or older who had at least one non-coresidential adult child aged 19 or older. The analyses were conducted by estimating a series of fixed effects models while adjusting for the nested structure of the data. Results: The results showed that first, a closer distance between an adult child and the parent was generally associated with the parent experiencing a decrease in depressive symptoms. Yet, the mental health benefit was smaller for parents aged 65 years or older whose closest living adult child was a son. Second, a closer distance was observed to affect chronic illness only among middle-aged parents (aged 45 to 64). When the closest living adult child was a daughter, the middle-aged parent experienced deterioration in their chronic illness. On the other hand, the opposite pattern was observed when the closest living adult child was a son. Conclusions: The parental age and gender of the adult child in closest proximity to the parent might have varying effects on parents' health. A closer distance between an adult child and their parent has a positive impact on the mental health of the parent as a whole, whereas the effect of living closer was mixed in relation to the parental physical health.

Three dimensional photoelastic study on the initial stress distributions of alveolar bone when retracted by lingual K-loop archwire (Lingual K-loop archwire를 이용한 발치공간 폐쇄시 초기응력 분포에 대한 3차원 광탄성학적 연구)

  • Byun, Bo-Ram;Kim, Sik-Sung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.343-353
    • /
    • 2002
  • This study was designed to investigate the stress distribution of alveolar bone in case of on masse retraction with lingual K-loop archwire using the 3-dimensional photoelastic stress analysis followed by stress freezing process. Lingual K-loop archwire which had loop in 15mm height was used and activated by retraction force of 350gm per each side. The results were as follows 1. Central incisor : As the closer side to crown, the larger tensile stress was distributed at both mesial and labial surfaces and the larger compressive stress was distributed at distal surface. As the closer side to root apex, the larger compressive stress was distributed at lingual surface. The compressive stress was distributed at root apex. 2. Lateral incisor : The tensile stress was distributed at the coronal side of mesial surface. The compressive stress was distributed at distal surface. As the closer side to crown, the larger tensile stress was distributed at labial surface. The tensile stress was distributed at coronal side and the compressive stress was distributed at apical side of lingual surface. The compressive stress was distributed at root apex. 3. Canine The tensile stress was distributed at coronal side and the compressive stress was distributed at apical side of mesial surface. The tensile stress was distributed at distal surface. As the closer side to crown, the larger tensile stress was distributed at both mesial and distal surfaces. The compressive stress was distributed at root apex. 4. Second premolar : The tensile stress was distributed at mesial surface. The compressive stress was distributed at coronal side and the tensile stress was distributed at apical side of distal surface. The compressive stress was distributed at coronal side of buccal surface. As the closer side to crown, the larger tensile stress was distributed at lingual surface. The compressive stress was distributed at root apex. 5. First molar . As the closer side to crown, the larger tensile stress was distributed at both mesial and distal surfaces. No stress was distributed at buccal surface and palatal root apex. As the closer side to crown, the larger tensile stress was distributed at both lingual surfaces. The compressive stress was distributed a4 buccal root apexes. 6. Second molar The compressive stress was distributed at all root apexes. As the closer side to crown, the larger compressive stress was distributed at both mesial and lingual surfaces, and the larger tensile stress at both distal and buccal surfaces. Transverse bowing effect was observed in on-masse retraction with lingual K-loop archwire, however vertical towing effect was not. Rather, reverse vortical bowing effect was developed.

A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems (태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구)

  • Kim, Chan-Hyeok;Park, Hyeon-Seok;Rho, Dea-Seok;Shin, Chang-Hoon;Yoon, Gi-Gab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

Analysis of Rear Closer of Vertical Launching System by Using Fluid-Structure Interaction Method (유체-고체 연성 해석 기법을 통한 수직발사대 후방 덮개의 거동 해석)

  • Lee, Younghun;Gwak, Min-cheol;Cho, Haeseong;Joo, Hyun Shig;Shin, Sang Joon;Yoh, Jai-ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.664-671
    • /
    • 2017
  • This paper presents a numerical analysis of behaviors of rear closer of vertical launch system under rocket plume based on fluid structure interaction analysis. The rocket plume loading is modeled by fully Eulerian method and elasto-plastic behavior of rear cover is calculated by total Lagrangian method based on a 9-node planar element. The interface motion and boundary conditions are described by a hybrid particle level-set method within the ghost fluid framework. We compare the fluid flow pattern between different rear closer models which are elast-plastic and rigid deformation.

  • PDF

Study on the Assessment of the Criteria on a Door Closer for the Optimum Design of the Access Door of a Smoke Control Zone (제연구역 출입문의 최적 설계를 위한 도어클로저의 기준 산정에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.66-71
    • /
    • 2013
  • The purpose of this study is to assess the criteria on a floor hinge and door closer for the optimum design of the access door of a smoke control room. The door opening force due to differential pressure is 60.75 N, 40.5 N, 32.91 N and 12.66 N when the differential pressure is 60 Pa, 40 Pa, 32.5 Pa and 12.5 Pa, respectively. The door opening force of the floor hinge and door closer to which the criteria of KS F 2806 are applied is 27.5 N, 40 N, 75 N, 100 N and 125 N for the Nos. 1, 2, 3, 4 and 5 class floor hinges and door closers, respectively. This study compared the differential pressure and opening force limits of floor hinges and door closers with the values specified in NFSC 501A and found that they exceeded the criteria specified in NFSC 501A. Therefore, it is necessary to reflect the differential pressure and smoke control wind speeds as well as the opening forces specified in NFSC 501A on the design of floor hinges and door closers. The installation conditions of floor hinges and door closers of access doors differ depending on the type and name of a smoke control damper. This study found that Nos. 1, 2 and 3 floor hinges and door closers could be installed for access doors with low differential pressure and that Nos. 1 and 2 floor hinges and door closers could be installed for access doors with normal differential pressure.

프린팅 월드-유럽 인쇄관련 산업동향

  • Jo, Gap-Jun
    • 프린팅코리아
    • /
    • s.14
    • /
    • pp.194-196
    • /
    • 2003
  • 본 고는 미국에서 발간되는 인쇄용 잉크 전문 잡지 'Ink World' 6월호에 게재된 기획기사 'Paper and Ink Suppliers Work Closer Together'를 중심으로 정리한 글이다.

  • PDF