• Title/Summary/Keyword: closed range

Search Result 635, Processing Time 0.027 seconds

Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room (음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화)

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

Study on Automatic Mixing of Nutrient Solution Using ion Electrodes for Closed-Loop Hydroponics (이온전극을 이용한 순환식 양액 자동 조제에 관한 연구)

  • 김민규;류관희;장유섭;김기영
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.425-432
    • /
    • 2002
  • This study was carried out to develop an automatic mixing system of nutrient solution for closed-loop hydroponics using ion electrodes. The results of the study are summarized as follows: 1. It appeared that ion-electrodes had not to be soaked into nutrient solution for a long time since it was much less durable than EC or PH sensors. Once ion-electrodes were soaked into real nutrient solution for a long time, they became unstable. 2. ion measurement modules, which were able to sample recirculated nutrient solution and easily wash and dry ion-electrodes, were developed in order to use ion-electrodes continuously. 3. The results of calibration tests on three kinds of ion electrodes presented that the time required to read measurement data was over 30 seconds. Using the calibration data the regression equations for the ion electrodes were developed. 4. An automatic nutrient-solution mixing system using the three kinds of ion electrodes was developed and then its accuracy was examined. The control errors of the mixing system using ion electrodes were in the range of 9.8 to 12%.

A simple analytical model for deriving the threshold voltage of a SOI type symmetric DG-MOSFET (SOI형 대칭 DG MOSFET의 문턱전압 도출에 대한 간편한 해석적 모델)

  • Lee, Jung-Ho;Suh, Chung-Ha
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.16-23
    • /
    • 2007
  • For a fully depleted SOI type symmetric double gate MOSFET, a simple expression for the threshold voltage has been derived in a closed-form To solve analytically the 2D Poisson's equation in a silicon body, the two-dimensional potential distribution is assumed approximately as a polynomial of fourth-order of x, vertical coordinate perpendicular to the silicon channel. From the derived expression for the surface potential, the threshold voltage can be obtained as a simple closed-form. Simulation result shows that the threshold voltage is exponentially dependent on channel length for the range of channel length up to $0.01\;[{\mu}m]$.

Preparation and Characterization of Biodegradable Poly(butylene succinate)(PBS) Foams

  • Lim, Sang-Kyun;Jang, Suk-Goo;Lee, Seok-In;Lee, Kwang-Hee;Chin, In-Joo
    • Macromolecular Research
    • /
    • v.16 no.3
    • /
    • pp.218-223
    • /
    • 2008
  • In order to obtain crosslinked poly(butylene succinate) (PBS) foams with a closed-cell structure, a commercial-grade PBS was first modified in the melt using two different branching agents to increase the melt viscosity. The rheological properties of the branched and crosslinked PBS were examined by varying the amount of the branching agents. The complex viscosity of the crosslinked PBS increased with increasing amount of the branching agent. However, it decreased with increasing frequency. When 2 phr of the branching agent was added to PBS, the storage modulus (G') was higher than the loss modulus (G") throughout the entire frequency range, showing that the addition of a branching agent increases the melt viscosity and elasticity of PBS effectively. Closed-cell PBS foams were prepared by mixing the chemical blowing agent with the crosslinked PBS. The effect of the foaming conditions such as temperature and time, and the amount of the crosslinking agent on the structure of the expanded PBS foams were also investigated.

Analysis of Components and Oxygen Consumption Rate for Zinc Concentrates in a Closed Chamber (아연정광의 성분분석 및 챔버내 산소소모량 평가)

  • Hae Dong Park;Eun Song Hwang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.6-11
    • /
    • 2023
  • Objective: This study was conducted to identify the cause of suffocation accident. Methods: We analyzed the components of zinc concentrates by ICP-OES (inductively coupled plasma optical emission spectroscopy) and tested the oxygen consumption by zinc concentrates in a 13.2-liter closed chamber. Results: Zinc, sulfur and iron were the main components of the four types of zinc concentrates, and accounted for 76~89% by weight. Zinc concentrates (0.5 or 0.927 kg) depleted the oxygen concentration from 20.9% to 7.4~18.9% during seven days. The rate of oxygen consumption was in the range of 3.0~11.0 mM/day·kg-sample at 21~24℃ and around 95% of free air space within the closed chamber. Conclusion: Since zinc concentrate consumes oxygen in a confined space, measures should be taken to prevent suffocation accident (such as ventilation and monitoring of oxygen concentration).

Load-deflection characteristics and plastic deformation of NiTi closed coil springs (수종의 니켈-티타늄 폐쇄형 코일 스프링의 하중-변위 특성 및 소성 변형 비교)

  • Son, Ah-Young;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.310-319
    • /
    • 2009
  • Objective: NiTi closed coil springs were reported to have relatively constant unloading forces. However, the characteristics of NiTi closed coil springs from various manufacturers have not been elucidated. The purpose of this study was to compare load-deflection characteristics of various NiTi closed coil springs and to find out the optimal range of extension. Methods: Seven kinds of NiTi closed coil springs from five manufacturers were tested. Load deflection curves were obtained at extension ranges from 2 mm to 30 mm. Also, springs were kept extended during a 4 week period, and then load deflection curves were obtained again. Results: Sentalloy (Tomy) and Jinsung blue (Jinsung) showed superelasticity in every extension ranges tested and showed plastic deformation of less than 1 mm. Ni-Ti (Ormco) showed superelasticity only after the springs were extended at or more than 10 mm, thereby meaning that clinicians should extend these springs at or more than 10 mm to utilize the superelasticity. Orthonol (RMO) and Nitanium (Ortho Organizers) did not show superelasticity. After 4 weeks of extension, all springs showed plastic deformation less than 1 mm when the extension was at or under 25 mm. Conclusions: The superelastic behavior of NiTi closed springs were different among various NiTi spring products, and some NiTi closed springs failed to show superelasticity.

Measurements of In-situ Thermal Conductivity of Closed Type Ground Heat Exchanger in Korea (국내의 주요 지역에서 밀폐형 열교환기의 열전도도 측정)

  • Jung, Kye-Hoon;Lim, Hyo-Jae;Han, Ji-Won;Park, Kyung-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3401-3406
    • /
    • 2007
  • This study was performed to acquire the reliable in-situ thermal conductivity of closed type ground heat exchanger used in ground source heat pump. We selected four sites(Cheonan, Daejeon, Daegu, Gwangju) which are central area of South Korea. Test results show that the effective thermal conductivities are 2.33 W/m$^{\circ}C$, 2.50 W/m$^{\circ}C$, 2.75 W/m$^{\circ}C$ and 2.86 W/m$^{\circ}C$. From this data, we can see that thermal conductivity varies about the range of 23% with the sites. Also, thermal conductivity increases up to 20% by changing grouting material from low salica sand to high one.

  • PDF

Effects of Convective Flow Fields on the Physical Vapor Transport Processes of $Hg_2Cl_2$ Crystals (염화제일수은 승화법 단결정 성장 공정에서의 대류 현상 연구)

  • Park, Jang-Woo;Kim, Geug-Tae;M.E. Glicksman
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.10a
    • /
    • pp.39-43
    • /
    • 1997
  • Mercurous chloride (Hg$_2$Cl$_2$) has many advantages in its applications to acousto-optic, and opto-electronic devices because it has the unique properties of a broad transmisson range, well into the far infra-red, a low acoustic velocity, a large birefringence, and a high acousto-optic figure of merit[1]. Hg$_2$Cl$_2$ has a high vapor pressure, hence single crystals are usually grown by physical vapor transport(PVT) method in closed silica glass ampoules. We discuss the application of the laser Doppler velocimetry to measure the flow field inside a closed ampoule. The experimental results, are discussed its relationship to computational model and compared to their expectations.

  • PDF

Correlation Between the External Laryngeal Length and the Habitual Speaking Fundamental Frequency (외 후두부 길이와 발화기본주파수 간의 상관관계)

  • Nam, Do-Hyun;Rheem, Sung-Sue;Choi, Hong-Sik
    • Phonetics and Speech Sciences
    • /
    • v.1 no.4
    • /
    • pp.187-193
    • /
    • 2009
  • For this study, the external laryngeal lengths of 9 females and 9 males with normal voices were measured together with their ages, heights, and weights, and after they read aloud sentences for 3 minutes, their habitual speaking fundamental frequencies, speaking low pitches, speaking high pitches, and vocal fold closed quotients were measured. The Spearman rank correlation analysis on these data showed a significant negative correlation between the external laryngeal length and the habitual speaking fundamental frequency for both females and males, a significant negative correlation between the external laryngeal length and the speaking high pitch for only males, a significant negative correlation between the external laryngeal length and the speaking low pitch for both females and males, and a significant positive correlation between the external laryngeal length and the vocal fold closed quotient for only males.

  • PDF

HARDWARE IN THE LOOP SIMULATION OF HYBRID VEHICLE FOR OPTIMAL ENGINE OPERATION BY CVT RATIO CONTROL

  • Yeo, H.;Song, C.H.;Kim, C.S.;Kim, H.S.
    • International Journal of Automotive Technology
    • /
    • v.5 no.3
    • /
    • pp.201-208
    • /
    • 2004
  • Response characteristics of the CVT system for a parallel hybrid electric vehicle (HEV) are investigated. From the experiment, CVT ratio control algorithm for the optimal engine operation is obtained. To investigate the effect of the CVT system dynamic characteristics on the HEV performance, a hardware in the loop simulation (HILS) is performed. In the HILS, hardwares of the CVT belt-pulley and hydraulic control valves are used. It is found that the engine performance by the open loop CVT ratio control shows some deviation from the OOL in spite of the RCVs open loop control ability. To improve the engine performance, a closed loop control of the CVT ratio is proposed with variable control gains depending on the shift direction and the CVT speed ratio range by considering the nonlinear characteristics of the RCV and CVT belt-pulley dynamics. The HILS results show that the engine performance is improved by the closed loop control showing the operation trajectory close to the OOL.