Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

유한 요소법을 이용한 맥진 파형의 자기장 변화 분석 (Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method)

  • 박태영;이상석
    • 한국자기학회지
    • /
    • 제24권3호
    • /
    • pp.90-96
    • /
    • 2014
  • 요골동맥의 움직임에 따라 손목의 "관" 위치에 놓인 영구자석이 요동함으로 자기장의 변화를 생성하였다. 맥동에 의존하는 자기장을 감지하는 홀소자가 구비된 집게형맥진기의 출력신호인 맥진파형 특성을 분석하였다. 유한요소법으로 전산모사한 자기장 파형과 실제 맥진 파형의 시간 특징점들은 거의 일치하였다. 한 개의 원통 소형 영구자석의 자기장 분포의 변화를 감지하는 홀소자 집게형맥진기 시뮬레이터를 제작하여 재현성과 유효성 있는 한방진단기기로 활용하는 기틀을 마련하였다.

홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구 (Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph)

  • 이대희;홍유식;이상석
    • 한국자기학회지
    • /
    • 제23권4호
    • /
    • pp.135-143
    • /
    • 2013
  • 요골 동맥의 중앙 부에 위치 한 "관"이란 곳에 영구자석 부착하여 맥의 움직임에 따라 발생하는 자기장의 변화를 홀센서로 정량화하여 맥진파형을 측정하는 집게형 맥진기를 개발하였다. 홀소자 맥진센서로 얻어진 전기적 신호로 심전도와 용적맥파계를 사용해 동시에 측정된 맥박수, 비침습적 혈압, 호흡수, 맥파전달속도와 공간맥파전달속도를 환자감시장치에 디스플레이하였다. 개발된 장치는 한방과 양방의 의료용 저장 매체와 새롭게 시도되거나 융합되어지고 있는 환자감시 장비 및 유비쿼터스 헬스케어 시스템 개발에 도움이 될 것이다.

영구자석과 홀소자로 구비된 집게형 맥진기를 이용한 맥진파형 측정과 분석 (Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device)

  • 손일호;이상석
    • 한국자기학회지
    • /
    • 제21권3호
    • /
    • pp.104-107
    • /
    • 2011
  • 비가압 상태에서 정확하게 측정한 맥진파형 신호를 얻기 위하여 영구자석과 홀소자로 구비된 안정시 휴대성이 가능한 집게형 맥진기 시제품을 개발하였다. 소형 영구 자석 1개 위치 변화로 얻은 요골동맥 맥진 파형의 4가지 중요 상관인자인 주기, 수축시간, 반사파시간, 절흔 시간들을 결정하여 5초간 수집한 실험값들을 서로 비교 분석하였다. 집게의 스프링에서 누르는 일정 압력을 사용해 가압 느낌 없이 재현성 있는 맥박수 및 혈압 측정함으로써 홀소자 집게형 맥진기 개발이 가능함을 보여주었다.

자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색 (Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device)

  • 유준상;장세진;선승호;홍유식;이상석
    • 대한한의진단학회지
    • /
    • 제17권1호
    • /
    • pp.63-76
    • /
    • 2013
  • The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.

자기장 측정 홀소자 집게형 맥진기를 이용한 허맥과 실맥 예측 알고리즘 개발 (Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field)

  • 이남규;김근호;이상석;유지혜;유준상;선승호;장세진;홍유식
    • 한국자기학회지
    • /
    • 제23권3호
    • /
    • pp.104-109
    • /
    • 2013
  • 소형 영구자석이 부착된 상태에서 요골동맥의 미세한 움직임으로 자기장 변화를 측정하는 홀소자 집게형 맥진기를 개발하였다. 이 맥진기를 통해서 얻은 120명의 임상데이터를 통계적 로지스틱 회귀분석으로 처리하여 허맥과 실맥을 예측하는 알고리즘의 특성을 연구하였다. 요골동맥파의 반사파 시간값과 절흔점 시간값이 허맥과 실맥을 예측할 수 있는 주요인자이였으며, 판별율은 65%이었다. 이로써 한의학적 허맥과 실맥을 예측하고 판별하는 진단지표로 사용할 가능성을 제하였다.

영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석 (Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device)

  • 김동영;이상석;현석산;이진규
    • 한국자기학회지
    • /
    • 제24권5호
    • /
    • pp.146-151
    • /
    • 2014
  • 영구자석과 홀소자로 구비된 집게형 맥진기를 이용하여 목 부위의 경추동맥의 맥진파형과 손목 부위의 요골동맥 맥진파형을 각각 측정하였다. 두 개의 맥진파형을 비교하여 얻은 맥파전달시간과 맥파전달속도를 분석하였다. 맥파전달속도는 기존의 방식으로 측정한 값과 유사한 약 8.5 m/s으로 나타났다. 재현성과 신뢰성이 있는 한방의료기기인 집게형 맥진기로 얻은 맥파전달속도를 기준하여 동맥경화도를 예측할 수 있음을 제시하였다.

홀센서 집게형 맥진기 요골동맥파에 FFT를 적용한 호흡수 추출 연구 (Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor)

  • 조현성;이상석
    • 한국자기학회지
    • /
    • 제22권5호
    • /
    • pp.178-182
    • /
    • 2012
  • 영구자석과 반도체 홀센서가 구비된 집게형 맥진기로 얻은 맥진파형에 고속 푸리에변환(FFT)을 적용하여 생체신호인 호흡수를 추출하였다. 추출된 호흡수는 맥진파형의 형태가 항상 변화하는 요인에 의존하는 심장의 운동에 대한 오차까지 고려하였다. 인위적인 호흡수 템포 15, 20, 30, 40, 50에 각각 측정한 맥진파형의 FFT 스펙트럼에서 피크값과 일치하는 주파수 0.125 Hz, 0.16 Hz, 0.25 Hz, 0.33 Hz, 0.41 Hz와 일치하였다. 100 s, 200 s, 300 s 동안 얻은 맥진파형 데이터에서 호흡성분 추출 알고리즘을 적용한 결과, 시간이 긴 300 s에서 FFT 스펙트럼 피크가 가장 크게 뾰쪽해지는 결과를 얻었다. 집게형 맥진기가 인체의 물리적인 영향을 주는 호흡수를 추출해 내는데 유용한 기기임을 확인하였다.

Analysis of Both Hands' Two Pulse Waveforms using a Clip-type Pulsimeter Equipped with Magnetic Sensing Hall Device

  • Rhee, Jin-Kyu;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.183-187
    • /
    • 2013
  • Two concurrent signals of the pulse wave measured from both hands' radial artery in un-pressurization condition using the prototype model of two clip-type pulsimeters with a permanent magnet and Hall device are investigated. The phase differences of two pulse waves from 22 subjects have some distinct points according to the handedness. Thus, the propagation of the pulse wave calculated from phase difference is both fast and slow to each other. It is confirmed that this phenomenon comes from the difference of blood vessel hardness between right- and left-hand of each subject rather than a quantity of muscle.