• Title/Summary/Keyword: clavicle fracture

Search Result 108, Processing Time 0.027 seconds

Operative Treatment of Posteriorly Displaced Fracture of the Distal Clavicle in Child - A Case Report - (후방으로 전위된 소아 쇄골 원위부 골절의 수술적 치료 - 1예 보고 -)

  • Park, Hyun-Soo;Chung, Tae-Won;Rha, Jong-Deuk;Jang, Youn-Soo;Lee, Byung-Hoon
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.207-210
    • /
    • 2006
  • We presented a case of posteriorly displaced fracture of the distal clavicle in Child. The closed reduction was failed due to posteriorly displaced proximal fragment and interpositon of trapezius muscle and periosteum. We found that periosteal sleeve and coracoclaviclar ligament and acromioclavicular ligament was intact. The open reduction should be considered for the treatment of the irreducible posteriorly displaced fracture of the distal clavicle in child.

Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

  • Park, Ho-Youn;Kim, Seok-Jung;Sur, Yoo-Joon;Jung, Jae-Woong;Kong, Chae-Gwan
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background: A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods: We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results: There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6-210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions: This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture.

Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer (보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.203-209
    • /
    • 2014
  • Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).

Recent Treatment Options for the Clavicle Fracture (쇄골 골절 치료의 최근 경향)

  • Oh, Joo-Han;Choi, Hye-Yeun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2012
  • Purpose: We sought to determine the appropriate management modality for clavicle fracture through the review of current literature. Materials and Method: This article provides an overview of the knowledge regarding clavicular fracture in adults, including epidemiology, classification, surgical indication, current technique, and results. We also addressed recent debates: the range of the surgical indication for mid-clavicular fracture and the introduction of anatomically precontoured plate as a new treatment modality. Result and Conclusion: Nonsurgical treatment has been regarded as the first choice in the management of clavicle fractures. Quite recently, mounting evidence has shown that adverse outcomes, after a nonsurgical treatment, such as nonunion and malunion, were more prevalent than previously assumed. Accordingly, the indications for surgical fixation appear to be broadening. However, given that the ideal treatment option remains to be determined, the appropriate treatment of clavicle fractures should be tailored based on careful assessment of individual patient's data and preference.

Simultaneous Bilateral Clavicle Fractures - A Case Report - (외상으로 동시에 발생한 양측 쇄골 골절 - 증례 보고 -)

  • Chang, Kee-Young;Roh, Kwon-Jae;Yun, Geon-Ung;Shin, Sang-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.125-128
    • /
    • 2009
  • Bilateral clavicle fractures caused by a strong external force acting at the same time is a rare case. While unilateral clavicle fracture with conservative treatment shows satisfactory clinical outcome, bilateral clavicle fractures with it has drawbacks such as severe pain, difficulty in rehabilitation and breathing. We experienced a rare case of bilateral clavicle fractures with multiple rib fractures, hemo-thorax and transverse process fracture of thoracic vertebra treated with surgical intervention promoted functional recovery and comfortable breathing. So, we report this case with article review.

  • PDF

Arthroscopic Stabilization for Displaced Lateral Clavicular Fractures: Can It Restore Anatomy?

  • Khan, Prince Shanavas;Yoo, Yon-Sik;Kim, Byung-Su;Lee, Seong-Jin;Ha, Jong Mun
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Background: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. Methods: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. Results: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. Conclusions: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.

Unusual Migration of Kirschner's Wire into Intervertebral Foramen after Lateral Clavicle Fracture Fixation - A Case Report

  • Lee, Jin-Ho;Chung, Jae-Yoon;Kim, Myung-Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.77-79
    • /
    • 2014
  • The migration of metallic devices such as Kirschner's wire (K-wire) from the shoulder is a well-recognized and significant complication of operation, the wire ending up in the lungs, the heart, the esophagus, the aorta or the subclavian artery. However, spinal migration is very rare. We report the case of a 72-year-old female patient with K-wire migration into the C7-T1 intervertebral foramen, 2 months after surgery for a lateral end fracture of left clavicle.

Anterior inferior reconstruction plate on acute midshaft clavicle fvacture (쇄골 간부골절의 전하방 부착 재구성 금속판을 이용한 치료)

  • Kang, Jae-Do;Kim, Kwang-Ryul;Kim, Hyung-Chun;Lim, Moon-Sup;Kim, Seong-Hoon;Kweon, Jun-Hyung
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose: Many different operative technique of mid-shaft clavicle fracture have been reported. The aim of this prospective study was to compare the results of anterior or anterior-inferior plating with superior plating on the acute mid-shaft fracture of clavicle Materials and Methods: From February1997 to February 2002, thirty-eight consecutive open reduction and internal fixation with reconstruction plates were performed in thirty-eight patients. from August 1999, anterior or anterior-inferior plating was mainly used, prospectively. The duration of follow-up averaged 17 months (range,23 to 43 months). The mean age was 38 years old (range,21 to 57 years old) on anterior or anterior-inferior plating group and 35 years old (range,24 to 55 years old) on superior plating group. The physician progress note, VAS patient complement score, Roentgenogram and ASES score was evaluated. Results: Four patients were lost to follow-up. There was no statistical difference on mean radiological bone union time (8.7 weeks vs. 8.6 weeks) and ASES score (92 vs 94) at inferior and superior plating groups (P > 0.05). VAS patient complement score was very good or excellent on anterior or anterior-inferior group, average score was 1.1 (ranger,0 to 2) compare with superior plating group (P < 0.05). There were two cases of infection, 1 case of failed fixation on superior plating group and 1 case of delayed union on anterior inferior plating group. Conclusion: Anterior inferior plating on acute clavicle midshaft fracture results in excellent patient complement score compare with conventional superior reconstruction plate.

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

Comparison of the Quality of Clavicle Fracture Three-dimensional Model Printing by Open Source and Commercial use Digital Imaging and Communications in Medicine Stereolithography File Conversion Program (공개용과 상업용 DICOM STL 파일변환 프로그램으로 출력한 삼차원 프린팅 쇄골 골절 모델의 품질비교)

  • Oh, Wang-Kyun;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.61-66
    • /
    • 2018
  • The recent 3D printing technology is used in various medical, manufacturing, and education fields and is more efficient in terms of production process, time, and cost than existing production. Especially in fracture surgery, interest and research have been focused on improving accuracy, shortening of operation time and recovery time, and reducing reoperation. However, because of the financial and technical problems of the 3D printer and the file conversion program, the 3D printing is made directly at the hospital, and it is not generally used for diagnosis of fracture and surgical research. In this study, to solve those problems, clavicle CT imaging was switched into Osirix Open Source DICOM Viewer, Stereolithography file conversion programs and commercial Terarecon 3D DICOM Viewer, file conversion programs, and then clavicle fracture model was directly made through 3D printer of fused filament fabrication wire additive processing method, and then the accuracy of the shape was compared and analyzed. Clavicle fracture models printed in two methods were blind-tested on clinicians of general hospitals' orthopedics and radiologic technicians with over 10 years of experiences, and then their analysis opinions of resolution reviews were analyzed. The result showed no difference. The 3D printing model with open source DICOM STL file conversion program used was applicable to clinical, so it is considered useful in precision diagnosis of fracture and operation plans.