• 제목/요약/키워드: clamping pressure

검색결과 89건 처리시간 0.023초

하이드로포밍 공정을 이용한 무용접 부품체결 기술개발에 관한 연구 (A study on the hydro-embedding technology in the tube hydroforming process)

  • 김동규;박광수;안익태;한수식;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.241-244
    • /
    • 2003
  • The productivity of hydroforming process can be increased by combining pre-forming process and post-forming process such as the bending, piercing and the embedding process. Therefore in this study, integrated studies on the hydro-embedding technology have been performed by analyzing the deformed mode of the tubes and the optimal process parameters. In the case of the embedding test the characteristics of the embedded parts, such as the shape of the screw tip, screw thread and shape of thread were investigated at various process conditions. To measure the clamping force between the embedded part and the tube, special measuring device was used.

  • PDF

수치해석을 통한 7인치 도광판 사출압축성형 공저범위 예측 (Numerical Prediction of Process Window for Injection-Compression Molding of 7-inch LGP)

  • 홍석관;민인기;강정진;윤경환
    • 소성∙가공
    • /
    • 제20권1호
    • /
    • pp.5-10
    • /
    • 2011
  • The main objective of the present study is to predict the process window of injection-compression molding corresponding to the capability of an injection machine for fabricating 7 inch LGP. The open distance and volume filled after injection stage were found to be two important factors that affect critical requirements such as flow length, injection pressure and clamping force for the process. Process window for the key factors was also predicted by response surface method. As a result, predicted process window for open distance and volume filled after injection stage satisfying the critical requirement with a given injection machine was in the range of 60 ~ 75%, and 104.00 ~ 104.25%, respectively.

대형 캠 타입 이송장치의 설계에 관한 연구 (Study on the Design of Cam-type Transfer Unit)

  • 이택민;이동윤;양민양
    • 대한기계학회논문집A
    • /
    • 제28권1호
    • /
    • pp.31-39
    • /
    • 2004
  • This paper presents design solutions for cam type transfer unit in which feeding, lifting, and clamping motions are generated by cams. In order to achieve faster transfer motion, each designed cam must satisfy the given specifications such as velocity, acceleration, jerk, pressure angle, cam thickness, and torque. To reduce absolute torque magnitude and torque variation, a conjugate cam and a torque reduction cam are used respectively. The conjugate cam eliminates the redundant pre-load by using complementary cam to avoid jumping between a cam and a follower. The torque reduction cam reduces the torque variation by applying opposite torque to a cam shaft. The experimental result shows the reductions of the absolute torque value and torque variation. The improvement of working speed and life span of cam type transfer unit can be expected.

고분자 전해질 연료전지의 매니폴드 및 분리판 유동분배 특성 분석 (Numerical Study on the Flow Characteristics of Manifold and Bipolar Plate in Polymer Electrolyte Fuel Cells)

  • 조중원;유상필;김민진;이원용;김창수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.320-323
    • /
    • 2006
  • A numerical study is made of a manifold and bipolar plate in polymer electrolyte fuel cells, the aim of the present study is to describe the characteristics of flow pattern In manifold and bipolar plate. The present work shows that the flow pattern in the bipolar plate is affected by the penetration flow through GDL characterized by clamping pressure and GDL intrusion in to a channel area. Manifold geometry also affects the flow distribution. The recirculation flow by bent duct destroy even distribution In manifold, the present work shows that corner rounding can improve the manifold performance.

  • PDF

THERMO-MECHANICAL ANALYSIS OF OPTICALLY ACCESSIBLE QUARTZ CYLINDER UNDER FIRED ENGINE OPERATION

  • Lee, K.S.;Assanis, D.N.
    • International Journal of Automotive Technology
    • /
    • 제1권2호
    • /
    • pp.79-87
    • /
    • 2000
  • Analytical approach was followed in this work under both the steady state and transient operating conditions to find optimum boundary conditions, where the optically accessible quartz engine can run safely without breaking. Temperature and stress distribution was predicted by FEM analysis. In order to validate thermal boundary condition, model reliability and constraint, outside cylinder temperature was measured and previous study was also followed up numerically. To reduce thermal stress level, three types of outside cooling (natural, moderate forced and intensive forced convection) were considered. Effects of clamping force and combustion pressure were conducted to investigate mechanical stress level. Cylinder thickness, was changed to fine the optimum cylinder thickness. The versatile results achieved from this work can be basic indication, which is capable of causing a sudden quartz cylinder breaking during fired operation.

  • PDF

폴리에틸렌 하수관 연결용 전기발포융착 이음관에 관한 연구 (A Study of Electro-foaming Fusion Wrap for Polyethylene Sewer Pipe)

  • 계형산;주경훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.343-354
    • /
    • 2012
  • A electro-foaming fusion wrap fitting for polyethylene sewer pipe was built and foaming mechanism has been studied. A foaming sheet, supporting sheet and clamping band is assembled into a all-in-one structured electro-foaming fusion wrap fitting. To specify foaming and fusion of electro-foaming fusion wrap for PE sewer pipe, series of fusion tests were performed in various conditions. A parallel plate compression test up to 50 % of inner diameter deflection has been performed to check integrity of fusion quality and it was found that there were no visible signs of crack in wrapped area of fitting. Also air tightness test based on KS M 3511-2 has been performed to evaluate perfectness of wrap fusion quality and we found there were no pressure drop up to 10 times higher value than KS standard regulation.

원자로 부품의 수중 밀링 가공을 위한 4축 밀링 머신의 설계 (Design of 4-axes Milling Machine for Underwater Milling of Nuclear Reactor Parts)

  • 이동규;이기용;김성균;이근우;박진호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.351-354
    • /
    • 2003
  • A new milling machine was designed and manufactured for underwater cutting of rotary specimen racks(RSR) used in the Korea Research Reactor. To cut out intermediate level radioactive stainless steel parts from RSR effectively and safely, the machine was designed to be operated in four directions of X, Y, Z axes and a rotation upon Z axis. The stress and displacement of main frame were simulated by using a structural analysis tool(Design Space) and the pressure of clamping device was evaluated.

  • PDF

GMT 평판의 볼트조인트 강도 평가 (Estimation of Bolted Joint Strength of Flat Plate of Glass-Mat Reinforced Thermoplastics)

  • 강완석;민지현;이재욱;임용택
    • 대한기계학회논문집A
    • /
    • 제27권10호
    • /
    • pp.1636-1643
    • /
    • 2003
  • In this study, bolted joint made of Glass-Mat Reinforced Thermoplastics (GMT) specimen was under tensile loading to investigate the relation between joint strength and glass-fiber weight fraction of the flat plate specimen. The effect of molding conditions such as the initial size of a GMT charge and molding temperatures was investigated under plane strain condition. In consideration of the specimen geometry, minimum end distance and width of the specimen to induce the bearing fracture mode of the bolted joint were determined. And finally, the effect of the outer diameter of washer and clamping pressure on joint strength was also investigated. Since joint strength is dependent on the local glass-fiber weight fraction, experimentally measured strength was modified, considering its irregular values of the specimen molded under various processing conditions in order to obtain a reasonable correlation between the two.

Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

  • Kim, In Sook;Byun, Joung Hun;Yoo, Byung Ha;Kim, Han Yong;Hwang, Sang Won;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • 제46권3호
    • /
    • pp.212-215
    • /
    • 2013
  • A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day.

A Review of Anesthesia for Lung Transplantation

  • Kim, Hye-Jin;Shin, Sang-Wook;Park, Seyeon;Kim, Hee Young
    • Journal of Chest Surgery
    • /
    • 제55권4호
    • /
    • pp.293-300
    • /
    • 2022
  • Lung transplantation is the only treatment option for patients with end-stage lung disease. Although more than 4,000 lung transplants are performed every year worldwide, the standardized protocols contain no guidelines for monitoring during lung transplantation. Specific anesthetic concerns are associated with lung transplantation, especially during critical periods, including anesthesia induction, the initiation of positive pressure ventilation, the establishment and maintenance of one-lung ventilation, pulmonary artery clamping, pulmonary artery unclamping, and reperfusion of the transplanted lung. Anesthetic management according to the special risks associated with a patient's existing lung disease and surgical stage is the most important factor. Successful anesthesia in lung transplantation can improve hemodynamic stability, oxygenation, ventilation, and outcomes. Therefore, anesthesiologists must have expertise in transesophageal echocardiography, extracorporeal life support, and cardiopulmonary anesthesia and understand the pathophysiology of end-stage lung disease and the drugs administered. In addition, communication among anesthesiologists, surgeons, and perfusionists during surgery is important to achieve optimal patient results.