• Title/Summary/Keyword: claddings

Search Result 79, Processing Time 0.019 seconds

An Experimental Study on Combustion Characteristics of Aluminum Composite Panels for Flame Retardant and General Materials (난연소재와 일반소재 알루미늄복합패널의 연소특성 비교에 관한 실험적 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Kim, Mi-Suk
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.105-111
    • /
    • 2012
  • In this research, aluminum composite panels of the general materials and fire retardant materials as building claddings make researches about fire performance comparison analysis. Test methods of the small and medium cone calorimeter experiments and SBI (Single Burning Item) experiments was applied to the determination. As a result, in the experiments peak heat release rate cone calorimeter the general aluminum composite panel $1,293kW/m^2$ ($75kW/m^2$), flame-retardant aluminum composite panel $70kW/m^2$ ($75kW/m^2$) was measured. In the SBI experiments fire growth rate the general fire aluminum composite panel is approximately 743 W/s and the flame-retardant aluminum composite panel is approximately 97 W/s of the value were measured. Thus, a standards enactment are urgently required in this case it is used as building claddings of the aluminum composite panel by fire risk assessment.

Polarization-independent temperature sensor using cladding layers of the overlay waveguide coupled with a side-polished fiber (측면 연마 광섬유와 결합된 상부 도파로의 클래딩을 이용한 편광 무의존 온도센서)

  • 손경락;김광택;송재원
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.467-472
    • /
    • 2002
  • In this paper, we propose a polarization-insensitive temperature sensor using a thermo-optic effect of the upper and (or) lower cladding of a planar waveguide in contact with a side-polished fiber. A microscope cover glass with thickness of a 170 ${\mu}{\textrm}{m}$ is adopted as an overlay waveguide because this waveguide opposes sudden temperature change and ensures polarization-insensitive responses. The measured polarization-dependence loss is less than 0.3 dB. The temperature can be detected as a result of the shift in coupling wavelength of the sensor. We investigate the shift in coupling wavelength as a function of the temperature variation with respect to the different thermo-optic coefficients of lower and upper claddings. We also show that the temperature sensitivity of the device can be easily controlled by the thermo-optic coefficients of lower and upper claddings of the overlay waveguide.

HIGH BURNUP CHANGES IN UO2 FUELS IRRADIATED UP TO 83 GWD/T IN M5(R) CLADDINGS

  • Noirot, J.;Aubrun, I.;Desgranges, L.;Hanifi, K.;Lamontagne, J.;Pasquet, B.;Valot, C.;Blanpain, P.;Cognon, H.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.155-162
    • /
    • 2009
  • Since the 90's, EDF and AREVA-NP have irradiated, up to very high burnups, lead assemblies housing $M5^{(R)}$ cladded fuels. Post-irradiation examination of high burnup $UO_2$ pellets show an increase in the fission-gas release rate, an increase in fuel swelling, and formation of fission-gas bubbles throughout the pellets. Xenon abundances were quantified, and phenomena leading to this bubble formation were identified. All examinations provided valuable data on the complex state of the fuel during irradiation. They show the good behavior of these fuels, exhibiting various microstructures at very high burnups, none of which is likely to lead to problems during irradiation.

Local buckling behaviour of steel plate elements supported by a plastic foam material

  • Mahendran, M.;Jeevaharan, M.
    • Structural Engineering and Mechanics
    • /
    • v.7 no.5
    • /
    • pp.433-445
    • /
    • 1999
  • Sandwich panels comprising steel facings and a polystyrene foam core are increasingly used as roof and wall claddings in buildings in Australia. When they are subjected to loads causing bending and/or axial compression, the steel plate elements of their profiled facing are susceptible to local buckling. However, when compared to panels with no foam core, they demonstrate significantly improved local buckling behaviour because they are supported by foam. In order to quantify such improvements and to validate the use of available design buckling stress formulae, an investigation using finite element analyses and laboratory experiments was carried out on steel plates that are commonly used in Australia of varying yield stress and thickness supported by a polystyrene foam core. This paper presents the details of this investigation, the buckling results and their comparison with available design buckling formulae.

Wear Characteristics of Submerged-Arc Cladding (서브머지드 아크 클래딩에 의한 표면 피복층의 마모특성)

  • 김권흡;권오양
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.179-186
    • /
    • 2003
  • This paper is to investigate the wear behavior of submerged-arc claddings by the wear test with a ball-on-disk type wear testing machine in air. The specimens were clad with Stoody105 alloy wire on a medium carbon steel (SM45C) substrate by submerged-arc cladding process under different welding parameters. The wear behavior of the cladding through ball-on-disk test has been studied under the wear load from 5 to 16 N and the sliding speed from 8 to 35 cm/s. The weight loss of the specimen was measured. Scanning electron micrographs of the worn surface show a layer of oxide film formed on the worn surface. Oxidation wear mechanism controls the wear process. The spatting of the oxide is caused by the repeated rubbing fatigue mechanism.

Effect of Cooling Rate on the Behavior of the Embrittlement in Zircaloy-4 Cladding (냉각속도가 지르칼로이-4 피복관의 취성에 미치는 영향)

  • Kim, Jun Hwan;Lee, Myoung Ho;Choi, Byoung Kwon;Jeong, Yong Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.2
    • /
    • pp.112-118
    • /
    • 2005
  • Study was focused on the effect of the cooling rate on the embrittlement behavior of Zircaloy-4 cladding simulated Loss Of Coolant Accident (LOCA) environment. Claddings were oxidized at given temperature and given time followed by various water quenching in the range of $0.6^{\circ}C$ and $100^{\circ}C$ per second. Cladding failed after water quenching above the threshold oxidation. Threshold oxidation was decreased as the cooling rate increased, which is due to the matensite structure formed during fast cooling rate.

Analytical criteria for fuel fragmentation and burst FGR during a LOCA

  • Khvostov, G.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2402-2409
    • /
    • 2020
  • Analytical criteria for the onset of fuel fragmentation and Burst Fission Gas Release in fuel rods with ballooned claddings are formulated. On that basis, the GRSW-A model integrated with a fuel behaviour code is updated. After modification, the updated code is successfully applied to simulation of the Halden LOCA test IFA-650.12. Specifically, the calculation with Burst Fission Gas Release during the test resulted in prediction of cladding failure, whereas it could not be predicted at the test planning, before new models were implemented. A good agreement of the current model with experimental data for transient Fission Gas Release in the tests IFA-650.12 and IFA-650.14 is shown, as well.

Numerical simulation of the effects of localized cladding oxidation on LWR fuel rod design limits using a SLICE-DO model of the FALCON code

  • Khvostov, Grigori
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.135-147
    • /
    • 2020
  • A methodology for evaluation of mechanical and thermal effects of localized non-axisymmetric oxidation in zircaloy claddings on LWR fuel reliability is proposed. To this end, the basic capabilities of the FALCON fuel behaviour code are used. Examples of methodology application to adjustment of selected operational limits for modern BWR fuel rods, to capture effects of the excess local oxidation, are presented. Specifically, the limiting rod internal pressure for the onset of cladding lift-off is reduced, depending on initial excess oxidation spot sizes. Also, the power limits for Anticipated Operational Occurrences are adjusted, to preclude fuel melting and cladding failure due to PCMI and PCI-SCC in the affected fuel rods.

Embrittlement Behavior of Zirconium Alloy in Quenching Heat Treatment (급랭 열처리시 지르코늄 합금의 취성 거동)

  • Kim, Jun Hwan;Lee, Jong Hyuk;Choi, Byoung Kwon;Jeong, Yong Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.4
    • /
    • pp.216-222
    • /
    • 2004
  • Study was focused on the quenching embrittlement property of Zircaloy-4 cladding simulated Loss Of Coolant Accident (LOCA) environment in terms of high temperature oxidation and phase transformation. Property in LOCA condition of advanced cladding that contained Nb element was also investigated. Claddings were oxidized at given temperature and given time followed by water quenching. The results showed that ${\beta}$ phase which formed at quenching stage has an influence on cladding property. In case of advanced cladding, Nb retards cladding oxidation, thus enhances quenching resistance.

Measures for the Failure Evaluation of SNF Cladding During the Transportation

  • Noh, J.S.;Kim, H.A.;Kim, T.W.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.11a
    • /
    • pp.105-106
    • /
    • 2018
  • It is important to set up a reasonable failure criterion for cladding, because being able to determine the cladding integrity during transportation is essential for the evaluation of SNF transportation system. There are a few of measures which can be used as a failure criterion for cladding subjected to its specific failure mode. Therefore, to select and to use appropriate failure criterion measures, i.e. strain(UE), $K_{IC}$, and CSED would be a key in evaluating the cladding integrity during transportation with every aspects. In order to justify and quantify that criterion properly, various experiments for the mechanical properties of the claddings with different conditions shall be implemented, which data will enable to justify the failure criteria proposed.

  • PDF