• Title/Summary/Keyword: circulated water

Search Result 97, Processing Time 0.023 seconds

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System (모세유관 바닥복사 냉·난방 시스템의 성능평가)

  • Seo, Yu-jin;Kim, Taeyeon;Leigh, Seung-bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

Effects of Post-Harvest Bulk Management System Using Rice Processing Complex on Labor Saving and Quality of Barley (보리 산물처리에 의한 품질변화와 생력효과)

  • 이춘우;윤의병;구본철;백성범;손영구;서세정;남중현;김완석
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.6
    • /
    • pp.475-478
    • /
    • 2002
  • Post-harvest treatment for barley production requires many steps including drying, cleaning, and packing, and these steps be needed many labor input. Rice processing complex (RPC) is useful for post harvest management system in rice production. However, it is rare to be used for barley production. This study was conducted to explore the variations of quality and labor saving between conventional method and bulk-management system in post-harvest using RPC. The sorting rate was not different between manual method and bulk management. The hardness of non-polished grain was ranged 10,175-10,329 g/$3.14mm^2$, and that for non-polished grain was higher than that for polished grain, but there was not different between drying method. There was not be showed the hunter's value such as L, a and b according to drying method. Cooking characters such as water absorption ratio, swelling ratio, and water soluble extracts by circulated or continued dryer was higher than manual drying using solar heat. Labor input per ha for each cultivation process in bulk-management of barley using rice processing complex was 21 hours, compared to 46 hr/ha in the conventional method, labor input was greatly saved by up to 54.3% in the post-harvest bulk management system.

Underground Heat Transfer Characteristics of the Underground Heating System for Soil Sterilization in Greenhouse (온실 내 토양소독을 위한 지중난방시스템의 지중 열전달 특성)

  • Park, Kyung-Kyoo;Ha, Yu-Shin;Hong, Dong-Hyuck;Jang, Seung-Ho;Kim, Jin-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.108-115
    • /
    • 2010
  • This study was conducted to estimate the optimum temperature and required time for soil sterilization when heated water was circulated through underground heating pipes in the greenhouse which solar heat was influenced to the temperature of soil during the summer day. Two different types of heating pipes were used for the experiment. One was a polyethylene pipe(XL) and the other was a corrugated ring shaped stainless steel pipe(STS). The results of the studies were summarized as follows; By measuring the thermal characteristics of the XL and STS, it was examined that the average temperature differences of the inlet and outlet were $8.5^{\circ}C$ and $13.3^{\circ}C$, the average flowrates were 15.3 L/min and 5.6 L/min, and the average radiation powers were 9.1 kW and 4.1 kW, respectively. As results of the regression analysis of underground temperatures, when average soil temperature was$35^{\circ}C$, an average water temperature was $80^{\circ}C$, and XL was used, it was estimated that the possible heat transfer distance, the required time for heat transfer and heat flux to reach the underground temperature of $60^{\circ}C$ were 300 mm, 230 hours, and $7.57kW/m^2$, respectively.

DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH, ORIFICE DISTANCE AND MATERIAL

  • Moon, Jeong-Ho;Chung, Hung-Ho;Sung, Ki-Woung;Kim, Uh-Chul;Rho, Jae-Seong
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.375-384
    • /
    • 2005
  • To investigate the flow-accelerated corrosion (FAC) dependency of carbon steel (A106 Gr. B) and low-alloy steels (1Cr-1/2Mo, 21/4Cr-1Mo) on pH, orifice distance, and material, experiments were carried out. These experiments were performed using a flow velocity of 4 m/sec (partly 9 m/sec) at pH $8.0\~10.0$ in an oxygen-free aqueous solution re-circulated in an Erosion-Corrosion Test Loop at $130^{\circ}\;{\ldots}$ for 500 hours. The weight loss of the carbon steel specimens appeared to be positively dependent on the flow velocity. That of the carbon and low-alloy steel specimens also showed to be distinguishably dependent on the pH. At pH levels of $8.0\~9.5$ it decreased, but increased from 9.5 to 10.0. Utility water chemistry personnel should carefully consider this kind of pH dependency to control the water system pH to mitigate FAC of the piping system material. The weight loss of the specimens located further from the orifice in the distance range of $6.8\~27.2$ mm was shown to be greater, except for 21/4Cr-1Mo, which showed no orifice distance dependency. Low alloy steel specimens exhibited a factor of two times better resistance to FAC than that of the carbon steel. Based on this kind of FAC dependency of the carbon and low-alloy steels on the orifice distance and material, we conclude that it is necessary to alternate the composition of the secondary piping system material of NPPs, using low-alloy steels, such as 21/4Cr-1Mo, particularly when the system piping has to be replaced.

Daegu metropolitan government's plan of relocation of water intake plant and collaborative governance between regions (대구시 취수원 이전계획과 지역 간 협력적 거버넌스)

  • Choi, Byung-Doo;Chae, Eun-Hye;Yang, Min-Ji
    • Journal of the Korean association of regional geographers
    • /
    • v.22 no.1
    • /
    • pp.64-85
    • /
    • 2016
  • This paper is to consider the development process of conflict between Daegu and Gumi which has been arisen from Daegu city's plan of relocation of water intake plant. It first argues that water is a major common and public resource which is circulated through the social process as well as the natural one, and hence that conflicts within or between regions due to its allocation should be resolved or managed by construction of collaborative governance in which all stake-holders participate. In particular, it is pointed out that collaborative governance would be not only oriented to a normative goal, but also be mobilized as a strategic means. On the basis of this conceptual consideration, this paper explores the development process of conflict caused by Daegu city's plan of relocation of water intake plant, and analyze the starting conditions and deliberation process of the public-private committee which has been constituted through a consensus between Daegu and Gumi city government. It concludes that the current interruption of the committee has happened, because it has been mobilized politically as a strategic means for regional hegemony, not as a normative one to resolve the conflict.

  • PDF

Design Optimization of Two-Way Pump Casing through Flow Analysis (양방향 펌프의 유동 해석을 통한 펌프 케이싱의 최적설계)

  • Kim, Dong-Hwi;Noh, Yoojeong;Lim, O-Kaung;Choi, Eun-Ho;Choi, Ju Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • A two-way pump can reduce costs by draining and circulating water out and into the drum of the washing machine using a single motor whereas a conventional one-way pump uses two motors for doing the same function. However, when the water is drained through the drainage outlet in the two-way pump casing, a backward or inhalation flow occurs and the water flows to the circulation outlet. Likewise, when the water is circulated, the backward flow or inhalation makes the water flow to the drainage outlet. In this study, design optimization of the two-way pump casing is performed to maximize its performance while improving backward flow and inhalation occurring inside of the pump casing. For this, design variables of the pump casing that mainly affect the performance of the pump such as flow rate and torque of the motor were selected through the analysis of mean. Using response surface models for the performances, the ratio of the flow rate to the torque was maximized with satisfying the constraints for the back flow and inhalation through design optimization.

Seoul Dynamics - Cheonggyecheon Threshold Plaza Design - (서울 다이나믹스 - 청계천 시점부 광장 설계 -)

  • Kim Jung-Yoon;ParkKim Office
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.1 s.114
    • /
    • pp.92-106
    • /
    • 2006
  • The process of designing Cheonggyecheon Entrance Plaza began with researching four keywords: plaza, restoration. modernity and icon. The outcome of the research was reinterpreted into and informed the design. An urban plaza must not only be a stage for civic life but should also be a portrait of the city to which it belongs. Many Korean plazas, however, are treated as if they are parks. Yeouido Park, which was originally a vast urban void, and Seoul Plaza, recently paved with grass, are good example. The strong 'green myth' can hinder socio-political activities. Cheonggyecheon cannot be said to have been 'restored', since it is still disconnected from its origin and upper streams, and the water is circulated by electricity. So it is better understood as an artificial urban waterfront, rather than an ecologically restored stream. This fact might diminish its ecological value, but not its recreational one. The entrance plaza therefore should reflect that the new stream brings back an 'experience', not only water itself. At the same time, the catch phrase of this restoration project was 'post-modern'. The demolished Cheonggye Expressway represents the 'economy drive' of the 1970s, so the newly opened Cheonggyecheon serves as a perfect counterpart to it. But modernity in Korea is the spirit that made many of the good things, not only its shortcomings, we have now. And from the philosophy of this restoration project, we can see that it is still an ongoing attitude in a way. Remnant of Cheonggye Expressway can evoke our nostalgia for the era. There are plenty of symbols in Seoul, both as architecture and objects. But none of them provide citizens with experience, other than the experience of looking at them. Cheonggyecheon Entrance Plaza is a good place to serve as an icon for a dynamic Seoul. From the research, the designer concluded that this plaza should commemorate the incomparable horizontal experience of Cheonggyecheon and the old expressway, amid the vertical metropolis. The Pedestrian Sculpture, which people can stroll on and look out over Cheonggyecheon, is to be made of steel cladding with a core structure and represents the dynamism of the stream, Seoul and contemporary Korea. The choice of material and the steel structure are also ways of creating the icon. The Water Plaza, the space underneath the ramp, will accommodate people and their urban activities, providing an opportunity to play with water. The Waterblades will be a device for the dramatic beginning of the stream, simultaneously camouflaging ugly openings in the outlets. The Wall of Archaeology is to be made with pre-fab resin blocks, translucent enough so that people can see through any archaeological findings of the site. The strong water-resistant character of resin makes the wall steady throughout the flood season as well. Cheonggyecheon restoration project is an effort to combine contemporary urban demand with the once-existing physicality by evoking our nostalgia for it. The project itself shows many socio-political issues of present-day Korea. The entrance plaza design thus is focused on suggesting an icon for the metropolis, simultaneously celebrating the stream itself. Within this space, people will be exposed to a unique experience that any 'green myth' cannot offer.

A Preliminary Verification of the Influences of Hydrologic Regime Change and Nutrients Influx on Vegetation Recruitment on Riparian Bars (하천식생 이입 현상에 대한 수문현상 변화와 영양염류 영향의 예비 검증)

  • Woo, Hyoseop;Kang, Joon-goo;Cho, Hyung-Jin;Choi, Yi-song;Park, Moon-hyeong
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.284-290
    • /
    • 2015
  • In this study, two hypotheses were examined to preliminarily verify for the vegetation recruitment and establishment on riparian bars in unregulated rivers; hydrologic regime change and nutrients influx into streams. In order to preliminarily verify the first hypothesis, precipitation patterns were analyzed during a period from March through to May when reeds, the most common riparian vegetation in Korea, germinate and start to grow in riparian areas. The results show that during the last 35 years, the total precipitation during the three-month period decreased by about 15 %, while the total annual one increased by about 15% in Korea. In order to verify the second hypothesis, a preliminary experiment was conducted with a set of two-vegetative flumes for one year. In this experiment, a stream flow with reeds on the riparian sand bars was simulated with a flume with reeds planted on the sand bed and water with a concentration of 3.5 mg of N flowing in the flume for four hours. For comparison, clean water was circulated in the same way in another flume for simulating a stream flow without N. The experimental results show that the growth rate of reeds in N-mixed flow exceeds that in clean water flow by about 30%. The above two results could explain the phenomenon of change in unregulated rivers from white river to green river in Korea, although they were obtained through limited extents of analysis and experiment.

Ecosysteme de I′Etang de Berre (Mediterranee nord-occidentale) : Caracteres Generales Physiques, Chimiques et Biologiques

  • Kim, Ki-Tai
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.2
    • /
    • pp.247-258
    • /
    • 2004
  • Climatological, hydrological and planktonical research studies, measurements of primary production and photosynthetic efficiency from December 1976 to December 1978 have been carried out in two brackish lakes: Lake Etang de Berre and Lake Etang de Vaine located in the French Mediterranean coast, in the region of Carry-le-Rouet located on the north-west Mediterranean near Marseilles, and in fresh water inflows from 4 Rivers (Touloubre, Durance, Arc, Durancole) to Lake Etang de Berre. Physico-chemical parameters were measured for this study: water temperature, salinity, density, pH, alcalinity, dissolved oxygen (% saturation), phosphate, nitrate, nitrite, silicate etc. Diverse biological parameters were also studied: photosynthetic pigments, phaeopigments, specific composition and biomass of phytoplankton, primary pelagic production etc. Climatical factors were studied: air-temperature, solar-radiation, evaporation, direction (including strength) of winds, precipitation and freshwater volume of the four rivers. The changes in Lake ‘Etang de Berre’ ecosystem depend on the quality of the water in the Durance River, and on the effects of seawater near the entrance of the Caronte Canal. The water quality of the lake varies horizontally and vertically as a result of atmospheric phenomena, maritime currents and tides. The distribution of water temperatures is generally heterogeneous. Southeasterly winds and the Northeasterly Mistral wind are important in the origins of circulated and mixed water masses. These winds are both frequent and strong. They have, as a result, a great effect on the water environment of Lake Etang de Berre. In theory, the annual precipitation in this region is well over eight times the water mass of the lake. The water of the Durance River flows into Lake Etang de Berre through the EDF Canal, amounting to 90% of the precipitation. However, reduction of rainfall in dry seasons has a serious effect on the hydrological characteristics of the lake. The temperature in the winter is partially caused by the low temperature of fresh water, particularly that of the Durance River. The hydrological season of fresh and brackish water is about one month ahead of the hydrological season of sea water in its vicinity. The salinity of Lake Etang de Berre runs approximately 3$\textperthousand$, except at lower levels and near the entrance to the Caronte Canal. However, when the volume of the Durance River water is reduced in the summer and fall, the salinity rises to 15$\textperthousand$. In the lake, the ratio of fresh water to sea water is six to one (6:1). The large quantities of seston conveyed by rivers, particularly the Durance diversion, strongly reduce the transparency in the brackish waters. Although the amount of sunshine is also notable, transparency is slight because of the large amount of seston, carried chiefly by Tripton in the fresh water of the Durance River. Therefore, photosynthesis generally occurs only in the surface layer. The transparency progressively increases from freshwater to open seawater, as mineral particles sink to the bottom (about 1.7kg $m^{-2}a^{-1}$ on the average in brackish lakes). The concentration of dissolved oxygen and the rate of oxygen saturation in seawater (Carry-le-Rouet) ranged from 5.0 to 6.0 $m\ell$ㆍ.$1^{-1}$, and from 95 to 105%, respectively. The amount of dissolved oxygen in Etang de Berre oscillated between 2.9 and 268.3%. The monographs of phosphate, nitrate, nitrite and silicate were published as a part of a study on the ecology of phytoplankton in these environments. Horizontal and vertical distributions of these nutriments were studied in detail. The recent diversion of the Durance River into Lake Etang de Berre has effected a fundamental change in this formerly marine environment, which has had a great impact in its plankton populations. A total of 182 taxa were identified, including 111 Bacillariophyceae, 44 Chlorophyceae, and 15 Cyanophyceae. The most abundant species are small freshwater algae, mainly Chlorophyceae. The average density is about $10^{8}$ cells $1^{-1}$ in Lake Etang de Berre, and about double that amount in Lake Etang de Vaine. Differences in phytoplankton abundance and composition at the various stations or at various depths are slight. Cell biovolume V (equivalent to true biomass), plasma volume VP (‘useful’ biomass) and, simultaneously. the cell surface area S and S/V ratio through the measurement of cell dimensions were computed as the parameters of phytoplankton productivity and metabolism. Pigment concentrations are generally very high on account of phytoplankton blooms by Cyanophyceae, Chlorophyceae and Cryptophyceae. On the other hand, in freshwaters and marine waters, pigment concentrations are comparatively low and stable, showing slight annual variation. The variations of ATP concentration were closely related to those of chlorophyll a and phytoplankton blooms only in marine waters. The carbon uptake rates ranged between 38 and 1091 mg$Cm^{-2}d^{-1}$, with an average surface value of 256 mg; water-column carbon-uptake rates ranged between 240 and 2310 mg$Cm^{-2}d^{-1}$, with an average of 810, representing 290 mg$Cm^{-2}$, per year 45 000 tons per year of photosynthetized carbon for the whole lake. Gross photosynthetic production measured by the method of Ryther was studied over a 2-year period. The values obtained from marine water(Carry-le-Rouet) ranged from 23 to 2 337 mg$Cm^{-2}d^{-1}$, with a weighted average of 319, representing about 110 gCm$^{-2}$ per year. The values in brakish water (Etang de Berre) ranged from 14 to 1778 mg$Cm^{-2}d^{-1}$, with a weighted average of 682, representing 250 mg$Cm^{-2}$ per year and 38 400 tons per year of photosynthesized carbon for the whole lake.