• 제목/요약/키워드: circulated water

검색결과 97건 처리시간 0.024초

이산화탄소 하이드레이트 슬러리의 생성 및 수송기술개발 (Development of Formation and Transportation Techniques for CO2-Hydrate Slurry)

  • ;윤린
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.341-349
    • /
    • 2017
  • Formation and transportation of $CO_2$-hydrate slurry was conducted by circulating saturated water with $CO_2$ through a double-tube type heat exchanger which was cooled down by brine. The inner diameter and circulation length of the heat exchanger were 1 inch and 20 m, respectively. Water in tank was supersaturated by injected $CO_2$ and the operation pressure was maintained at 3,000 to 4,000 kPa with fluid-temperature of less than $9^{\circ}C$. $CO_2$ hydrate mass fraction was calculated based on density of $CO_2$-hydrate slurry mixture. Results showed that the $CO_2$-hydrate slurry could be circulated without blockage for 1 hr. Circulation status of the $CO_2$-hydrate slurry was also visualized.

Reactive Extrusion of Starch-g-Polyacrylonitrile in the Preparation of Absorbent Materials

  • Yoon, Kee-Jong;Carr, M.E.;Bagley, E.B.
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1990년도 제2차 학술발표초록집
    • /
    • pp.8-8
    • /
    • 1990
  • A new method for the graft polymerization of acrylonitrile onto starch is presented. Graft polymerization of acrylonitrile onto starch and the subsequent hydrolysis in sodium hydroxide solution to prepare absorbents is well known. This process has been utilized to produce the commercial product, Super Slurper. In a typical batch process, ~5% starch in water mixture is gelatinized at $95^{\circ}C$ under stirring for 1 hour then cooled to room temperature. The graft polymerization itself is carried out for approximately 2 hours at $25~30^{\circ}C$ on the gelatinized starch by eerie ion initiation. In this study, graft polymerization of acrylonitrile onto starch via a reactive extrusion process which is a continuous, efficient process is described. Initial concentration of starch in water is 35% and the reaction temperatures are between $50~80^{\circ}C$. However, the most significant difference in the reactive extrusion process is the short time in which the graft polymerization takes place. Preliminary results on the properties of graft polymerization products obtained from the reactive extrusion process are compared to those obtained from the batch process as well as the absorbency of the hydrolyzed samples. Absorbent material has also been prepared by sequential grafting and saponification in the extruder followed by a 2 hour heat treatment of the extrudate in an air circulated oven at $100^{\circ}C$.

  • PDF

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 신재생에너지
    • /
    • 제5권4호
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

수공냉 대류방식을 이용한 1.2kW급 LED 조명등 개발 (Development of 1.2kW LED Light with Water-Air Circulation)

  • 윤병우;송종관;박장식;권홍배
    • 한국전자통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.615-622
    • /
    • 2015
  • 반도체 제조기술의 발달로 고효율 및 고휘도의 LED가 개발됨에 따라 재래식 조명들로부터 LED를 이용한 조명으로 조명산업이 이동하는 추세이다. LED 조명등은 에너지 효율이 재래식 조명보다 뛰어나지만 많은 열이 발생한다는 단점이 있다. 특히 대형 LED 조명등에서는 이러한 발열문제가 심각한 실정으로, LED에 의한 메탈기판의 열은 납땜 부분을 열화시켜 조명등의 수명을 단축시키는 주된 원인이 된다. 따라서 대형 조명등을 개발하기 위해서는 이러한 열 문제를 해결하는 것이 매우 중요하다. 본 연구에서는 대형 LED 조명등에서 열문제를 해결하기 위한 방법을 제시하였고, 제시한 방식으로 1200W급 LED 조명등을 개발하였다. 본 연구에서 이용한 방법은 LED 조명등에 워터재킷을 설치하여 냉각수를 채웠으며, 소형의 수중펌프를 이용하여 냉각수를 순환시키는 방법을 이용하였다.

EC 기준 파프리카 순환식 수경재배에서 양액 교체 주기에 따른 양액 중의 이온 균형 및 각 이온의 EC 기여도 변화 (Changes in Ion Balance and Individual Ionic Contributions to EC Reading at Different Renewal Intervals of Nutrient Solution under EC-based Nutrient Control in Closed-loop Soilless Culture for Sweet Peppers (Capsicum annum L. 'Fiesta'))

  • 안태인;손정익
    • 원예과학기술지
    • /
    • 제29권1호
    • /
    • pp.29-35
    • /
    • 2011
  • EC 기준의 순환식 수경재배시스템에서 재사용 양액 내의 이온 농도의 변화와 각 이온의 EC 기여 비율의 변화는 안정적인 양액 관리를 위해서 고려되어야 할 중요한 요인이다. 본 연구는 초기 생육단계 파프리카의 EC 기준 순환식 수경재배에서 교체 주기에 따른 재사용 양액 내 이온 농도, 이온균형 및 이온의 EC 기여도의 변화를 조사하여 재사용 양액의 적정 분석 주기를 규명하고자 수행하였다. 실험은 파프리카의 평균 마디수가 13마디일 때 시작하였고, 처리 종료시점에서는 평균 마디수가 18마디였다. 1개의 암면 슬라브당 3주의 파프리카가 재배되었다. 처리는 재사용 양액의 교체 주기에 따라 각각 1주, 2주, 3주, 4주 교체 처리구로 구성되었다. 양액은 일사비례제어방식으로 급액되었다. 배액은 배액 탱크에 수집된 후에 당일 관수가 종료된 후 혼합 탱크에서 EC $2.69dS{\cdot}m^{-1}$가 될 때까지 희석되었다. 혼합된 양액은 익일의 양액으로 사용되었다. 재사용 양액은 주기적으로 수집하여 분석되었다. 교체 주기에 따른 이온 농도의 변화는 처리별 차이가 나타나지 않았다. 모든 처리구에서 이온 농도의 변화 범위는 각각 $K^+$ 5-8, $Ca^{2+}$ 11-14, $Mg^{2+}$ 2.0-2.7, $Na^+$ 0.5-0.6, $NO_3{^-}$ 14-19, ${SO_4}^{2-}$ 4-5, ${PO_4}^{3-}$ 1-4, $Cl^-$ $0.3-0.5meq{\cdot}L^{-1}$와 같았다. 교체 주기에 따른 이온 균형 변화는 크지 않았다. 그러나 전체 처리구에서 이온 비율의 변화는 일정한 경향을 나타냈다. 양이온 비율 변화는 $K^+$ : $Ca^{2+}$을 중심으로 나타났으며, 음이온은 ${SO_4}^{2-}$ : ${PO_4}^{3-}$를 중심으로 나타났다. 양액 중의 $K^+$, $NO_3{^-}$, $H_2PO_4{^-}$의 1가 이온과 $Ca^{2+}$, $Mg^{2+}$, ${SO_4}^{2-}$의 2가 이온의 활동도 계수는 각각 0.8-0.9, 0.5-0.6 사이에서 변하였고, 시간 경과와 함께 각 이온의 활동도 계수는 일정한 경향을 나타냈다. 각 이온이 양액의 EC에 기여한 비율은 $K^+$$NO_3{^-}$가 가장 컸고, 다음으로 $Ca^{2+}$, ${SO_4}^{2-}$, $Mg^{2+}$ 순으로 나타났다. 본 실험에 적용한 교체 주기 4주는 초기 생육단계의 파프리카를 EC 기준 순환식으로 수경재배 할 경우, 이온 농도 변화와 이에 따른 EC 기여도의 변화는 안정적인 범위 이내라고 판단된다.

Development of the Dynamometer Control System for Medium Speed Diesel Engines

  • Choi, Sang-Gu;Ryu, Sang-Hun;Kim, Jeom-Goo;Park, Ho-Chol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.243-247
    • /
    • 2004
  • The dynamometers which had made in a long time ago could not control the input/output quantity of water minutely and was sensitive to a noise since it was controlled by an analog control method. Therefore, a fully digital controlled system was urgently required to be robust against various noises. In this paper, the new system which can control the amount of circulated water in dynamometer was developed. This system is consisted of an industrial digital type controller and a servo motor. The industrial PLC was used as a main controller for the developed system, and the actuator and servo motor were used to control the inlet and outlet valve independently. The torque signal of load cell was fed back to the main controller to regulate the diesel engines load. Generally, an input/output valve position of the old dynamometer was fixed with a proper situation for an engine output test and the torque was changed according to the time interval. However, the torque value for the dynamometer could not be constantly kept because of the variation of the input water flow and fluid characteristic. Therefore, the automatic control of an inlet and outlet valve should be performed to keep the constant torque. So, the PID control method was applied to solve this problem. Also, the development of a web-based remote control system was described in this paper. This software will give us the convenience of operation, the more efficient operations, and the reduced operator workload for operation of the dynamometer. The application results of the system have been verified at actual diesel engine field.

  • PDF

퍼지론에 의한 강수예측 : I. 뉴로-퍼지 시스템과 마코프 연쇄의 적용 (Precipitation forecasting by fuzzy Theory : I - Applications of Neuro-fuzzy System and Markov Chain)

  • 나창진;김형수;김중훈;강인주
    • 한국수자원학회논문집
    • /
    • 제35권5호
    • /
    • pp.619-629
    • /
    • 2002
  • 대기에서의 물순환은 기후시스템이라는 커다란 공간 안에서 다양한 인자들의 상호작용을 통하여 이루어진다. 즉, 어떠한 기후 현상도 그 자체적으로 발생할 수는 없다. 따라서, 많은 연구자들은 영향인자들의 분석을 통하여 기후 변화를 이해하고자 노력하여 왔다. 본 연구에서는 다양한 인자에 의하여 영향을 받아 발생하는 강수량의 예측을 위하여 실제 세계의 근사적이고 부정확한 성질을 표현하는데 효과적인 퍼지 개념을 이용하였다. 예측을 위하여 적용한 모형은 크게 뉴로-퍼지 시스템과 마코프 연쇄이며, 일리노이주의 강수량 예측을 위하여 적용하였다. 예측은 강수량에 영향을 끼치는 다양한 대기순환 인자(예: 토양수분과 기온)를 고려하여 수행하였다. 예측 결과, 강수량 예측에 대기순환 인자들을 고려함으로써 모형의 예측능력을 향상시킬 수 있었고, 상대적으로 뉴로-퍼지 시스템의 예측이 보다 정확한 결과를 주었다.

태양열과 프레온 기체 압축열 복합온수기 개발 (The hot water production through the combination of solar thermal energy and freon gas compression heat)

  • 정현채;김기선;선경호;남승영;이종원
    • 태양에너지
    • /
    • 제10권2호
    • /
    • pp.18-27
    • /
    • 1990
  • 태양열과 프레온 R-12 기체 압축열 복합온수기를 개발하여 실용화할 수 있도록 했으며 개발 내용은 다음과 같다. 가. 라디에타형 집열기와 평판형 집열기를 고안하여 프레온 R-12 기체와 액체가 상변이를 하면서 순환하여 태양복사열과 간접복사열을 흡수하고 대기의 대류접촉전열을 통해 대기열을 효과적으로 흡수하도록 개발했다. 나. 저장조하부에 압축기를 위치하도록 하고 압축기 가동시 발생하는 압축기의 표면열과 압축기에서 발생된 기체열이 가장 효과적으로 저장조내에 주입되도록 압축기와 저장조내에 위치한 열교환기의 연결관을 축소화했다. 다. 저장조내에 압축된 기체로부터 열교환을 더욱 효과적으로 하기 위해 열교환기를 새로 고안하여 개발했다. 라. 2801, $50^{\circ}C$ 온수를 매일 생산하도록 하여도 혹한기에 월 6,000원 이하의 전기료가 소요됨을 실측했다. 마. 프레온 R-12 순환시스템으로 우리나라의 기후에서 태양열온수기 제작에 최대 장애요인인 동파문제를 완전제거 할 수 있었고 조작이 완전자동이며 하자 발생요인이 거의 없고 수명이 길며 제작단가가 낮아 보급에 큰 잇점이 있을 것임을 확인했다.

  • PDF

Investigation of the Thermal Performance of a Vertical Two-Phase Closed Thermosyphon as a Passive Cooling System for a Nuclear Reactor Spent Fuel Storage Pool

  • Kusuma, Mukhsinun Hadi;Putra, Nandy;Antariksawan, Anhar Riza;Susyadi, Susyadi;Imawan, Ficky Augusta
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.476-483
    • /
    • 2017
  • The decay heat that is produced by nuclear reactor spent fuel must be cooled in a spent fuel storage pool. A wickless heat pipe or a vertical two-phase closed thermosyphon (TPCT) is used to remove this decay heat. The objective of this research is to investigate the thermal performance of a prototype model for a large-scale vertical TPCT as a passive cooling system for a nuclear research reactor spent fuel storage pool. An experimental investigation and numerical simulation using RELAP5/MOD 3.2 were used to investigate the TPCT thermal performance. The effects of the initial pressure, filling ratio, and heat load were analyzed. Demineralized water was used as the TPCT working fluid. The cooled water was circulated in the water jacket as a cooling system. The experimental results show that the best thermal performance was obtained at a thermal resistance of $0.22^{\circ}C/W$, the lowest initial pressure, a filling ratio of 60%, and a high evaporator heat load. The simulation model that was experimentally validated showed a pattern and trend line similar to those of the experiment and can be used to predict the heat transfer phenomena of TPCT with varying inputs.

Discharge header design inside a reactor pool for flow stability in a research reactor

  • Yoon, Hyungi;Choi, Yongseok;Seo, Kyoungwoo;Kim, Seonghoon
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2204-2220
    • /
    • 2020
  • An open-pool type research reactor is designed and operated considering the accessibility around the pool top area to enhance the reactor utilization. The reactor structure assembly is placed at the bottom of the pool and filled with water as a primary coolant for the core cooling and radiation shielding. Most radioactive materials are generated from the fuel assemblies in the reactor core and circulated with the primary coolant. If the primary coolant goes up to the pool surface, the radiation level increases around the working area near the top of the pool. Hence, the hot water layer is designed and formed at the upper part of the pool to suppress the rising of the primary coolant to the pool surface. The temperature gradient is established from the hot water layer to the primary coolant. As this temperature gradient suppresses the circulation of the primary coolant at the upper region of the pool, the radioactive primary coolant rising up directly to the pool surface is minimized. Water mixing between these layers is reduced because the hot water layer is formed above the primary coolant with a higher temperature. The radiation level above the pool surface area is maintained as low as reasonably achievable since the radioactive materials in the primary coolant are trapped under the hot water layer. The key to maintaining the stable hot water layer and keeping the radiation level low on the pool surface is to have a stable flow of the primary coolant. In the research reactor with a downward core flow, the primary coolant is dumped into the reactor pool and goes to the reactor core through the flow guide structure. Flow fields of the primary coolant at the lower region of the reactor pool are largely affected by the dumped primary coolant. Simple, circular, and duct type discharge headers are designed to control the flow fields and make the primary coolant flow stable in the reactor pool. In this research, flow fields of the primary coolant and hot water layer are numerically simulated in the reactor pool. The heat transfer rate, temperature, and velocity fields are taken into consideration to determine the formation of the stable hot water layer and primary coolant flow. The bulk Richardson number is used to evaluate the stability of the flow field. A duct type discharge header is finally chosen to dump the primary coolant into the reactor pool. The bulk Richardson number should be higher than 2.7 and the temperature of the hot water layer should be 1 ℃ higher than the temperature of the primary coolant to maintain the stability of the stratified thermal layer.