A Novel Method for Calcium Hardness Control of Closed OCC Recycling System

  • Ow, Say-Kyoun;Shin, Jong-Ho;Song, Bong-Keun;Ryu, Jeong-Yong
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 1999년도 Proceedings of Pre-symposium of the 10th ISWPC
    • /
    • pp.164-171
    • /
    • 1999
  • A new technique for recycling process water was developed in order to reduce the calcium hardness of the closed OCC recycling system. Calcium ions present in the white water were precipitated as calcium carbonate by a reaction with sodium carbonate and the CaCO$_3$precipitates were easily removed from the system by a dissolved air flotation(DAF) method. After the DAF stage, CO$_2$-gas was purged into the water because the pH of Na$_2$CO$_3$-treated white water was reduced to neutral by CO$_2$gas. Since CaCO$_3$precipitate tends to stick onto the fine fiber surface and then is selectively removed from the water, a proper amount of suspended solid in the process water acts as an important factor in deciding the removal efficiency. By the application of Na$_2$CO$_3$addition - DAF - CO$_2$purging to the short circulated white water the calcium hardness was significantly reduced by 92% and more. The removal of calcium ions with fine fibers led to drainage improvement, reduction of fresh water consumption, and enhanced efficiency of wet-end chemicals.

압력식 급속 자동 여과장치의 여과성능 평가 (The Performance Estimation of Pressure-Type Rapid Automatic Filter)

  • 김덕진;유해성;신상윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.607-612
    • /
    • 2006
  • A pressure-type rapid automatic filter of 2000mm diameter and 170 ton/h filtering capacity was fabricated. In case of no external impurity inflow, the turbidity removal efficiency on raw water was experimented and the numbers of impurities of each sizes were analyzed by particle counter. As the result of circulated filtering, the raw water of 40 NTU was filtered to 0.44 NTU and the numbers of impurities above $1{\mu}m$ were removed by approximately 95%. With the filtering efficiency experimented and the mathematical method, the turbidity change of circulation water were calculated according to the inflow rate of external impurity and water treatment method of blow-down or filtering. The cost of blow-down water was calculated from above results. And simple payback period for this filter is calculated as about one year. Nowadays, as the cost of water is continuously increasing and environment regulations will be more strict, the water quality control using this filter will be expected to satisfy the user requirement.

  • PDF

해양심층수와 지하염수의 자원특성 비교분석 (Comparative Analysis of Resources Characteristics for Deep Ocean water and Brine Groundwater)

  • 문덕수;정동호;김현주
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.333-335
    • /
    • 2003
  • Deep Ocean Water is formed within restricted area including polar sea (high latitude) by cooling of surface seawater and globally circulated in the state of insolation with surface seawater. Although not as obvious as estuaries mixing, Brine groundwater is mixture of recirculated seawater and groundwater. Seawater having high osmotic pressure infiltrate into unconfined aquifer where is connected to the sea. The ions dissolved in seawater are present in constant proportions to each other and to the total salt content of seawater. However deviation in ion proportions have been observed in some brine groundwater. Some causes of these exception to the Rule of constant proportions are due to many chemical reactions between periphery soil and groundwater. While Deep Ocean Water (DOW) have a large quantity of functional trace metals and biological affinity relative to brine groundwater, DOW have relatively small amount of harmful bacteria and artificial pollutants.

  • PDF

Characteristics of Fluid Flow in the Fluidized Bed Shell and Tube Type Heat Exchanger with Corrugated Tubes

  • Ahn Soo Whan;Bae Sung Taek;Kim Myoung Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.198-205
    • /
    • 2004
  • An experimental study was carried on the characteristics of fluid flow and heat transfer in a fluidized bed shell-and-tube type heat exchanger with corrugated tubes. Seven different solid particles having same volume were circulated in the tubes. The effects of vari­ous parameters such as water flow rates, particle geometries and materials, and geometries of corrugated tubes on relative velocities and drag coefficients were investigated. The present work showed that the drag force coefficients of particles in the corrugated tubes were usually lower than those in the smooth tubes, meanwhile the relative velocities between particles and water in the corrugated tubes were little higher than those in the smooth tubes except the particles of glasses.

DEVELOPMENT OF A GRAIN CIRCULATING TYPE NATURAL AIR IN-BIN DRYER

  • Yun, H.S.;Chung, H.;Cho, Y.G.;Park, W.K.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.405-412
    • /
    • 2000
  • A natural air in-bin grain dryer with a grain circulator was developed for on farm use. Natural air drying test for rough rice was carried out to evaluate drying rate, uniformity of moisture content distribution in grain bed and energy consumption. It took 10 days to dry 8 ton of paddy rice from 21.9%(w.b) to 16.7%(w.b) moisture contents using the prototype dryer. The average drying rate was 0.52%/day. The uniformity of moisture content after drying was superior to the conventional natural air dryer where is grains were not circulated during drying periods. The dryer performance evaluation index was 738.3KJ/(kg.water), which was more effective than that of grain circulation t)pe hot air dryer(3,500-5,000 KJ/kg.water).

  • PDF

파형관 튜브가 있는 순환유동층 원통다관형 열교환기 내의 유체유동 (Fluid Flow in the Fluidized Bed Shell and Tube Type Heat Exchanger with Corrugated Tubes)

  • 안수환;이병창;배성택
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.406-412
    • /
    • 2003
  • An experimental study was carried on the characteristics of fluid flow and heat transfer in a fluidized bed shell-and-tube type heat exchanger with corrugated tubes. Seven different solid particles having same volume were circulated in the tubes. The effects of various parameters such as water flow rates, particle geometries and materials, and geometries of corrugated tubes on relative velocities and drag coefficients were investigated. The present work showed that the drag force coefficients of particles in the corrugated tubes were usually lower than those in the smooth tubes, meanwhile the relative velocities between particles and water in the corrugated tubes were little higher than those in the smooth tubes except the glass.

부식 모니터링을 이용한 콘크리트 내의 임계 염화물량 평가 (Estimation of Critical Chloride Threshold Value Using Corrosion Monitoring)

  • 배수호;이광명;정영수;김지상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.801-804
    • /
    • 2004
  • It should be noted that the critical chloride threshold level is not considered to be a unique value for all conditions. This value is dependent on concrete mixture proportions, cement type and constituents, presence of admixtures, environmental factors, steel reinforcement surface conditions, and other factors. In this study, the accelerated corrosion test for reinforcing steel was conducted by electrochemical and sea water-circulated method, respectively and during the test, corrosion monitoring by half cell potential method was carried out to estimate the critical chloride threshold value when corrosion for reinforcing steel in concrete was perceived. For this purpose, lollypop and beam test specimens were made for $31.4\%,\;41.5\%\;and\;49.7\%$ of w/c. respectively and then the accelerated corrosion test for reinforcing steel was executed. It was observed from the test that the time to initiation of corrosion was found to be different with water-cement ratio and the critical chloride threshold value was found to range from 0.91 to $1.27kg/m^3$.

  • PDF

자연순환회로를 이용한 대형 온수생산 시스템의 개발 (Development of a Large-Scale Hot Water Production System Using a Natural Circulation Loop)

  • 반태곤;이주동;이상천;김영길
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.233-241
    • /
    • 1999
  • 온수생산을 위하여 기존의 강제순환식이 아닌 자연순환식 회로를 이용한 대형 온수생산 시스템을 개발하였다. 그리고 이 시스템의 설계와 성능평가를 위한 시뮬레이션 프로그램을 개발하여 실용화 가능성을 제시하였다. 실제규모의 성능실험에서 주어진 기하학적 조건하에 시스템이 정상상태 운전 시 보일러 가열량(695㎾)일 때, 급수 유량이 0.3$\ell$/s 로 일정하게 순환함을 보였다. 그리고, 비정상상태로 작동 할 경우 순환유량이 0.4~0.6 $\ell$/s 로 시스템이 불안정함을 실험을 통해 확인하였다. 개발된 프로그램과 대형의 온수생산 시스템의 성능평가의 비교.검증을 통하여 시뮬레이션 프로그램을 이용한 시스템 설계에 적용될 수 있음을 보였다.

  • PDF

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

소수력 발전소 건설에 의한 삼천포 화력발전소 방류수로 흐름변화 예측 (Prediction of the Flow Pattern Changes using FLOW-3D Model in the Effluent Region of the Samcheonpo Thermal Power Plant (TPP))

  • 조홍연;정신택;김정대;강금석
    • 한국해안해양공학회지
    • /
    • 제18권4호
    • /
    • pp.338-347
    • /
    • 2006
  • 삼천포 화력발전소에서는 냉각수로 이용되고 방류되는 해수를 이용한 소수력 발전소가 건설되고 있다. 소수력 발전소는 발전량을 최대화하기 위해서는 규모를 크게 하는 것이 바람직하나, 소수력 발전소가 방류수로의 기능을 저해하지는 않는 범위에서 결정하여야 하기 때문에 적정규모를 결정하기 위해서는 수리학적인 고려가 필요하다. 본 연구에서는 현재 방류수로의 흐름특성 자료를 이용하여 3차원 흐름모형인 FLOW3D모형을 구축하고, 구축된 모형을 이용하여 소수력 발전소의 규모에 따른 방류수로 상류 지점의 수위 증가 양상을 예측하였으며, 발전소 건설에 따른 흐름변화 양상도 분석하였다 삼천포 소수력발전소 건설은 상류의 수위증가를 유발하며, 설계유량 156톤/초, 발전소 가동보 높이 3.8 m 기준에 대한 방류수로 Weir 상류지점의 수위는 4.97 m로 현 상태 4.32 m 보다 65 cm 정도 증가하는 것으로 파악되었다.