• Title/Summary/Keyword: circular rib

Search Result 29, Processing Time 0.024 seconds

Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened (한 측에서만 거칠기가 설치된 삼각덕트의 열전달과 압력강하 특성)

  • Ahn, S.W.;Lee, Y.S.;Lee, B.C.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.65-70
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent f)on· in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness Pitch ratio(P/e) of 4, 8 and 16 on the one side wall only The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70.000 to 10,000 The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement. measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion. namely the fin effect. And the results were compared with those of Previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

Characteristics of Pressure Drops in Square Channels with Twisted Tape Inserts plus Axial Interrupted Ribs (테이프와 거칠기가 설치된 사각 채널의 압력강하 특성)

  • Ahn, S.W.;Bae, S.T.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.38-42
    • /
    • 2006
  • Pressure drops and friction factors in square channels with twisted tape inserts plus axial interrupted ribs are investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, $e/D_h$, is kept at 0.057 and test section length-to-hydraulic diameter, $L/D_h$ is 30. The pressure drops and friction factor values are enhanced with axial interrupted ribs and twisted tape inserts. Square channels with twisted tape inserts plus axial interrupted ribs show the greatest pressure loss penalty in the present work. Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Wave Propagation in Swaged Panel (형상 보강 판넬의 파동 전파 특성)

  • 이종화;이정권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.253-256
    • /
    • 1996
  • Stiffened panels are very frequently used for body structures of automobiles, air-crafts, submarines, etc., to suppress the vibration level. Swaging technique is the modification of the configuration of panel itself, and this is prefered to rib-like stiffeners because it does not change the total weight of structure. In this paper, the transmissibility of vibratory power through swage is investigated, where the swage is modeled as an incomplete circular ring, utilizing the well-known transfer matrix method. The power transmission and reflection coefficients of swaged panel are estimated and compared with experimental results.

  • PDF

Experimental Study on the Structural Behavior of Concrete-Filled Circular Tubular Column to H-Beam connections without Diaphragm (다이아프램이 없는 콘크리트 충전 원형강관 기둥-H형강 보 접합부의 구조적 거동에 관한 실험적 연구)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.13-22
    • /
    • 1997
  • This paper is concerned with an experimental study on structural behavior of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections. The important parameters are the number of inner reinforced rib and the width of H-beam flange(100, 150, 200mm) with variable column thickness(5.8mm, 9.2mm, 12.5mm) around the joint between CFCT and H-beam. Test results are summarized for the displacement, strength, initial stiffness, failure mode and energy absorption capacity of each specimen. The purpose of this paper is to investigate the initial stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections. From the discussion about the test results, the basic data for non diaphragm connection design would be suggested.

  • PDF

Experimental shear strength evaluation of perfobond shear connector with various hole shapes

  • Zheng, Shuangjie;Zhao, Chen;Liu, Yuqing
    • Structural Engineering and Mechanics
    • /
    • v.67 no.2
    • /
    • pp.131-142
    • /
    • 2018
  • The perfobond connector, composed of a steel plate with a number of holes, serves as a certain type of shear connector in steel and concrete composite structures. Depending on limits in hole distances and rib heights, various hole shapes including circular-hole and long-hole are alternatives for perfobond connectors. This study presented the results of tests performed on 72 push-out specimens with perfobond connectors. The purpose was to evaluate the shear strength of perfobond connectors with circular-hole and long-hole. The effects of various parameters were investigated, including the hole diameter, the hole length, the hole height, the concrete strength, the existence, diameter and strength of rebar in the hole, the thickness, height and distance of perfobond ribs, and the thickness of concrete slabs. On the basis of 132 push-out test results in references and in this study, an analytical model was proposed by regression analysis to predict the shear strength of perfobond connectors. The proposed equation agreed reasonably well with the experimental results of perfobond connectors with different hole shapes.

Relief Hole for Improvement of Fatigue Strength in Welded Intersections of Transverse and Longitudinal Ribs in Orthotropic Deck (가로리브와 U리브 용접부의 피로강도 향상을 위한 응력완화홀)

  • Jung, Kyoung Sup;Nam, Seung Hoon;Yang, Keon Bong;Kim, Kyoung Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.419-430
    • /
    • 2014
  • On going researches which are being made on the welded joints at the intersections of closed ribs such as U-ribs with floor-beams in ortho-tropic steel decks still have been used the shape of scallops with or with not diaphragm inside. Stress Relief Hole(SRH) being presented in this study was investigated in order to reduce the fatigue damage in the intersections of U-rib with floor-beam. Finally, it is verified that circular SRHs sufficiently relief the concentration stress at the intersections of U-rib with floor-beam and shows that SRH can be offer one of the methods that can prevent the fatigue damage in these structural details.

An Analytical Study on the Strength Behavior of Column-Foundation Connection with High Tension Bolts (고장력 볼트 기둥-기초 연결부의 강도특성에 관한 해석적 연구)

  • Hwang, Dong A;Hwang, Won Sup;Ham, Jun Su;Jeong, Jin Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.121-128
    • /
    • 2016
  • In order to suggest a reasonable design for the circular concrete filled tube steel column-foundation connection applying high-tension bolts, Overall structural behavior and characteristics according to various variables of column-foundation connection are numerically analyzed using a commercial FE analysis program, ABAQUS. To that goal, finite element analysis is conducted on the basis of the previous study replacing anchor bolts to high-tension bolts, and the analytical results are validated by comparison with experimental results. Also, the various variables(embedded depth and grade of anchor, and height and thickness of rib) involved in behavior of the column-foundation connection are selected through analyzing the current design criteria, and the characteristics of the column-foundation connection are compared and analyzed according to the various variables. In case of the anchor bolts, Applying the high-tension bolts is more advantage and securing the embedded depth beyond 0.5D is recommendable. In case of the rib, a minimum of 0.5D for rib's height and $0.4t_b$ for rib's thickness should be secured to develop the structural performance.

A Study on the Improvement of Smoke Probe Performance in Diesel Vehicles Using Korean 147 Test Method (한국형 147검사 방법을 이용한 디젤자동차의 매연프로브 성능 향상 연구)

  • Kim, Jae-Yeol;Chae, Il-Seok;Kim, Sang yu;Yang, Dong Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.25-32
    • /
    • 2021
  • In the previous study, a study was conducted to improve the exhaust gas intake efficiency by improving the existing soot measurement probe in the shape and angle of the exhaust port. As a result, it can be seen that the smoke measurement performance according to the shape and angle is improved. In previous studies, the performance of the soot probe was not confirmed for the Korean KD 147 mode, which has a low suction flow rate and a long inspection time. So, we would like to confirm the improvement of the smoke probe performance of the Korean KD 147 mode, which is close to the actual driving conditions. The probe used in this study is another type of probe, and has a circular ring shape instead of a rib and variable center position unit, so the probe center hole is located close to the center of the exhaust pipe.

Experimental study on reinforced concrete filled circular steel tubular columns

  • Hua, Wei;Wang, Hai-Jun;Hasegawa, Akira
    • Steel and Composite Structures
    • /
    • v.17 no.4
    • /
    • pp.517-533
    • /
    • 2014
  • Experimental results of 39 specimens including concrete columns, RC columns, hollow steel tube columns, concrete filled steel tubular (CFT) columns, and reinforced concrete filled steel tubular (RCFT) columns are presented. Based on the experimental results, the load-carrying capacity, confined effect, ductility, and failure mode of test columns are investigated. The effects of the main factors such as width-thickness ratio (the ratio of external diameter and wall thickness for steel tubes), concrete strength, steel tube with or without rib, and arrangement of reinforcing bars on the mechanical characteristics of columns are discussed as well. The differences between CFT and RCFT are compared. As a result, it is thought that strength, rigidity and ductility of RCFT are improved; especially strength and ductility are improved after the peak of load-displacement curve.

Development of a Recursive Local-Correlation PIV Algorithm and Its Performance Test

  • Daichin Daichin;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.75-85
    • /
    • 2001
  • The hierarchic recursive local-correlation PIV algorithm with CBC(correlation based correction) method was developed to increase the spatial resolution of PIV results and to reduce error vectors. This new algorithm was applied to the single-frame and double-frame cross-correlation PIV techniques. In order to evaluate its performance, the recursive algorithm was tested using synthetic images, PIV standard images from Visualization Society of Japan, real flows including ventilation flow inside a vehicle passenger compartment and wake behind a circular cylinder with rib let surface. As a result, most spurious vectors were suppressed by employing CBC method. In addition, the hierarchical recursive correlation algorithm improved largely the sub-pixel accuracy of PIV results by decreasing the interrogation window size, increasing spatial resolution significantly.

  • PDF