Protection of the MMCs of HVDC Transmission Systems against DC Short-Circuit Faults

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.242-252
    • /
    • 2017
  • This paper deals with the blocking of DC-fault current during DC cable short-circuit conditions in HVDC (High-Voltage DC) transmission systems utilizing Modular Multilevel Converters (MMCs), where a new SubModule (SM) topology circuit for the MMC is proposed. In this SM circuit, an additional Insulated-Gate Bipolar Translator (IGBT) is required to be connected at the output terminal of a conventional SM with a half-bridge structure, hereafter referred to as HBSM, where the anti-parallel diodes of additional IGBTs are used to block current from the grid to the DC-link side. Compared with the existing MMCs based on full-bridge (FB) SMs, the hybrid topologies of HBSM and FBSM, and the clamp-double SMs, the proposed topology offers a lower cost and lower power loss while the fault current blocking capability in the DC short-circuit conditions is still provided. The effectiveness of the proposed topology has been validated by simulation results obtained from a 300-kV 300-MW HVDC transmission system and experimental results from a down-scaled HVDC system in the laboratory.

전력용 사이리스터 MCT를 이용한 무접점 직류차단기 (Contactless DC Circuit Breakers Using MOS-controlled Thyristors)

  • 심동연;김천덕;노의철;김인동;김영학;장윤석
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.45-50
    • /
    • 2000
  • Circuit breakers have traditionally employed mechanical methods to interrupt excessive currents. According to power semiconductor technology advances in power electronic device, some mechanical breakers are replaced with solid state equivalents. Advantages of the contactors using semiconductor devices include faster fault interrupting, fault current limiting, no arc to contain or extinguish and intelligent power control, and high reliability. This paper describes the design of a static $100{\pm}10%V$ and 0 to 50A DC self-protected contactor with 85A "magnetic tripping" and 100A interruption current at $2.2A/{\mu}s$ short circuit of load condition using a new power device the HARRIS MCT (600V-75A). The self-protection circuit of this system is designed by the classical ZnO varistor for energy absorption and turn-off snubber circuit ("C" or "RCD") of the MCT.

  • PDF

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

3D FEM해석을 통한 배선용 차단기의 전자반발력 해석 (Magnetic Repulsion Forces in MCCB by 3-D FEM Analysis)

  • 송중천;유만종;김용기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 2001
  • MCCB(Molded Case Circuit Breakers) is a multi-function safety device which, unlike other forms of protection, combines many protection features in a single unit. This paper is the analysis of magnetic repulsion forces with the breaking current 11.28kA, 22.5kA, 38.9kA and 45kA.

  • PDF

An Operating Circuits Design for preventing Electrostatic Discharge in Liquid Crystal Displays

  • Jo, Jo-Yeon;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.674-676
    • /
    • 2008
  • An electrostatic discharge (ESD) or a noise supplied from the outside has an effect on communication between the timing controller (TCON) and the memory element (EEPROM) through the interface between the timing controller and the memory element in liquid crystal displays (LCD). Therefore, we must apply ESD protection methods to LCD operating circuits for a normal operation. Our ESD protection circuit is to prevent from bi-directional communication errors between TCON and EEPROM due to an electrostatic discharge (ESD).

  • PDF

2차 전지 보호회로의 저전력 설계 기법 (Design methodology of the rechargeable battery protection IC for low-power implementation)

  • 이종훈;김상민;김상호;김대정;김동명
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.169-172
    • /
    • 2002
  • A protection integrated circuit which enables the stable operation of the rechargeable battery should be designed with a low-power architecture because it consumes the power of the battery. This paper proposed a low-power scheme especially when the several series-connected batteries are provided. By adopting a time sharing control of the batteries, the chip size and power consumption could be reduced.

  • PDF

다중셀 구조의 보호회로 IC의 저전력 설계기법 (Low-Power Design Scheme of Protection IC for Multi-Cell Configurations)

  • 이종훈;조충현;김대정;민경식;김동명
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1217-1220
    • /
    • 2003
  • A low-power design technique for lithium-ion Battery-Protection Integrated Circuit (BPIC) for multi cell configuration is proposed. The hardware sharing scheme with more precisely divided operating states in the detection range could reduce the power consumption significantly, especially during the normal state. The usefulness of the proposed scheme was confirmed through HSPICE simulations.

  • PDF

Loop Selective Direction Measurement for Distance Protection

  • Steynberg, Gustav;Koch, Geyhard
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.423-426
    • /
    • 2006
  • Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a dedicated measurement to ensure selectivity under all conditions. For the direction decision (measurement) a number of alternatives are available. This paper describes a loop selective direction measurement and illustrates by means of a typical fault why this is superior to a non loop selective direction measurement such as that based on negative sequence quantities.

누전차단기의 특성해석에 관한 연구 (A Study on Analysis of ELB Characteristics)

  • 김은배
    • 한국화재소방학회논문지
    • /
    • 제2권1호
    • /
    • pp.21-28
    • /
    • 1988
  • This paper deals with the optimal use of the ELB (Electric Leakage circuit Breaks) for the protection of low voltage distribution system. Since the ELB is recently used together for grounding fault while only the ground resistance was used in the past, the analysis of ELB characteristics is indispensible. By the quantitative analysis and the setting of limit the ground resistance and the ELB is derived and then the optimal use of the ELB is expected to contribute to the system protection.

  • PDF

철도 고압배전계통의 보호시스템 최적화 방안 연구 (Optimization of protection System on the Railway High Voltage power System)

  • 조웅기;창상훈;한성호;김왕곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.989-994
    • /
    • 2002
  • In case the fault occurs in railway high voltage power supply network, protective relaying system must selectively detect 1 wire ground fault of grounding or non-grounding system. And this study presents railway high voltage power supply system model using PSCAD/EMTDC Vet 3.08 for circuit analysis and fault studies. In this paper, we propose protection method of non-grounding system of railway high voltage power supply system. The result shows its usefulness.

  • PDF