• Title/Summary/Keyword: circuit modeling

Search Result 821, Processing Time 0.029 seconds

Convergence analysis technology for ship loading arm (선박용 로딩암에 적용할 수 있는 융합해석기술에 관한 연구)

  • Lee, Dae-Hee;Noh, Dae-Kyung;Lee, Geun-Ho;Park, Sung-Su;Jang, Joo-Sup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.258-268
    • /
    • 2017
  • In this study, we aim to converge a technology for analyzing the hydraulic circuit of a loading arm with an- other one for analyzing multi-body dynamics by utilizing analysis software SimulationX. Further, this study intends to overcome the limitations of the existing technology for analyzing a hydraulic circuit with a variation at the rotation center of the moving mass and the difficulty of incorporating the behavior in a gravity field. First, the specifications of the hydraulic circuit components were reflected in an analysis model to secure reliability. Hydraulic circuit modeling was then performed using a single analysis model with a verified reliability. Subsequently, the multi-body system (MBS) model of the loading arm was formed. Finally, the analysis model of the hydraulic circuit and the MBS model were converged to check if the circuit analysis result was exactly reflected in the MBS model. The convergence analysis model has development cost-saving effect because it is capable of predicting the dynamic behavior of an object without the prototype.

A Study on Interference between High Voltage Impulse Track Circuit(HVITC) and AF Track Circuit (고전압임펄스궤도회로(HVITC)와 AF 궤도회로간의 간섭에 대한 연구)

  • Lee, Hee-Jin;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.3
    • /
    • pp.232-240
    • /
    • 2015
  • Two types of track circuits are used in high speed railway car depots: one is High Voltage Impulse Track Circuit(HVITC); the other is AF track circuit. HVITC detects train occupation of blocks and broken rail; the AF track circuit is used for train onboard control system pretesting before departure. This testing is used to transmit train control information through the AF track circuit. The two systems are switched in turns for testing. We propose a system in which the AF track circuit is replaced by a loop cable that is installed on the inside rail; as such, engineers do not need to switch the systems. In cases in which the two systems run simultaneously, mutual interference may occur. In this paper, we identified this mutual interference by modeling of the two circuits.

Adaptive Learning Circuit For Applying Neural Network (뉴럴 네트워크의 적용을 위한 적응형 학습회로)

  • Lee, Kook-Pyo;Pyo, Chang-Soo;Koh, Si-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.534-540
    • /
    • 2008
  • The adaptive learning circuit is designed on the basis of modeling of MFSFET (Metal-Ferroelectric-Semiconductor FET) and the numerical results is analyzed. The output frequency of the adaptive learning circuit is inversely proportional to the source-drain resistance of MFSFET and the capacitance of the circuit. The saturated drain current with input pulse number is analogous to the ferroelectric polarization reversal. It indicates that the ferroelectric polarization plays an important role in the drain current control of MFSFET. The output frequency modulation of the adaptive learning circuit is investigated by analyzing the source-drain resistance of MFSFET as functions of input pulse numbers in the adaptive learning circuit and the dimensionality factor of the ferroelectric thin film. From the results, adaptive learning characteristics which means a gradual frequency change of output pulse with the progress of input pulse, are confirmed. Consequently it is shown that our circuit can be used effectively in the neuron synapses of neural networks.

Power output and efficiency of a negative capacitance and inductance shunt for structural vibration control under broadband excitation

  • Qureshi, Ehtesham Mustafa;Shen, Xing;Chang, Lulu
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.223-246
    • /
    • 2015
  • Structural vibration control using a piezoelectric shunt is an established control technique. This technique involves connecting a piezoelectric patch, which is bonded onto or embedded into the vibrating structure, to an electric shunt circuit. Thus, vibration energy is converted into electrical energy and is dissipated through a network of electrical components. Different configurations of shunt have been researched, among which the negative capacitance-inductance shunt has gained prominence recently. It is basically an analog, active circuit consisting of operational amplifiers and passive elements to introduce real and imaginary impedance on the vibrating structure. The present study attempts to model the behavior of a negative capacitance-inductance shunt in terms of power output and efficiency using circuit modeling software. The shunt model is validated experimentally and is used to control the structural vibration of an aluminum beam, connected to a pair of piezoelectric patches, under broadband excitation. The model is also used to determine the optimal parameters of a negative capacitance-inductance shunt to increase the efficiency and predict the voltage output limit of op-amp against the supply voltage.

Modeling of Solar Radiation Using Silicon Solar Module

  • Kim, Joon-Yong;Yang, Seung-Hwan;Lee, Chun-Gu;Kim, Young-Joo;Kim, Hak-Jin;Cho, Seong-In;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Purpose: Short-circuit current of a solar module that is widely used as a power source for wireless environmental sensors is proportional to solar radiation although there are a lot of factors affecting the short-circuit current. The objective of this study is to develop a model for estimating solar radiation for using the solar module as a power source and an irradiance sensor. Methods: An experiment system collected data on the short-circuit current and environmental factors (ambient temperature, cloud cover and solar radiation) during 65 days. Based on these data, two linear regression models and a non-linear regression model were developed and evaluated. Results: The best model was a linear regression model with short-circuit current, angle of incidence and cloud cover and its overall RMSE(Root Means Square Error) was 66.671 $W/m^2$. The other linear model (RMSE 69.038 $W/m^2$) was also acceptable when the cloud cover data is not available.

A Study on the Equivalent Circuit Modeling for Harmonics Analysis by Field Tests (현장시험에 의한 고조파 해석용 등가회로 모델링에 관한 연구)

  • 김경철;최종기;백승현;김종욱
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed It has been also known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages, and the soil resistivity and ground resistance under case study system were made and the corresponding equivalent circuit for the harmonics analysis was developed This equivalent circuit model was simulated numerically and graphically through the use of MATLAB and CDEGS software packages, and adequate results were obtained.

Circuit Modeling of Transition from Stripline to Dual Slotline for the Notch Antenna

  • So, Joon-Ho;Kim, Jun-Yeon;Lee, Moon-Que;Cheon, Chang-Yul
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.1
    • /
    • pp.22-29
    • /
    • 2003
  • A circuit model for the transition of stripline to dual slotline and a segmented method to analyze a notch antenna are presented. For the circuit model of the transition, the characteristic impedance, dispersions, and the shorted impedance of dual slotline are calculated and approximated with the closed-form expressions. The segmented analysis method allows to get readily an optimized results for the dual slotline-fed notch antenna. As a design example, a notch antenna is segmented into a 4'h order Marchand balun and a dual slot 134 notch antenna, and tested to show the validity of the proposed circuit model.

  • PDF

New Approach for Transient Radiation SPICE Model of CMOS Circuit

  • Jeong, Sang-Hun;Lee, Nam-Ho;Lee, Jong-Yeol;Cho, Seong-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1182-1187
    • /
    • 2013
  • Transient radiation is emitted during a nuclear explosion and causes fatal errors as upset and latch-up in CMOS circuits. This paper proposes the transient radiation SPICE models of NMOS, PMOS, and INVERTER based on the transient radiation analysis using TCAD (Technology Computer Aided Design). To make the SPICE model of a CMOS circuit, the photocurrent in the PN junction of NMOS and PMOS was replaced as current source, and a latch-up phenomenon in the inverter was applied using a parasitic thyristor. As an example, the proposed transient radiation SPICE model was applied to a CMOS NAND circuit. The CMOS NAND circuit was simulated by SPICE and TCAD using the 0.18um CMOS process model parameter. The simulated results show that the SPICE results were similar to the TCAD simulation and the test results of commercial CMOS NAND IC. The simulation time was reduced by 120 times compared to the TCAD simulation.

Voice Traffic Estimation using Kalman-filtering and Performance Evaluation of a Circuit Switched Network with Grid Topology (Kalman-Filter를 이용한 음성트래픽 예측 및 회선 교환 격자 구조망 성능 평가)

  • 문경덕;이정규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.5
    • /
    • pp.452-459
    • /
    • 1992
  • In this paper, we have estimated voice traffics using Kalman-filtering for upcoming years and evaluated performance of a grid topology circuit switched network using above outcomes. Since measurement errors and modeling errors are considered in Kalman-filtering, the system is estimated more accurately than by using any other estimation methods. A grid topology circuit switched network has alternative routing paths, therefore it is more reliable than any other networks. In this paper, we have calculated the call blocking probabilities, which is the key measuremens of performance evaluation in circuit switched networks. by using estimated voice traffics for upcoming years.

  • PDF

Systematic Approach of Internal Parameters for Equivalent Electrical-Circuit Modeling(EECM) of a Li4Ti5O12(LTO) cell (Li4Ti5O12(LTO) 배터리 등가회로 모델링을 위한 내부 파라미터 체계적 해석)

  • Lee, Pyeong-Yeon;Yoon, Chang-O;Park, Jin-Hyeong;Kim, Jonghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.174-181
    • /
    • 2018
  • This study introduces a systematic approach to selecting the internal parameters applied to the equivalent electrical-circuit model (EECM) of a lithium titanium oxide ($Li_4Ti_5O_{12}$; LTO) rechargeable cell. Based on the dynamic characteristic of the cell, a simplified EECM consisting of an open-circuit voltage (OCV), an ohmic resistance, and an RC ladder is fabricated. To select the internal parameters of a simplified EECM, experiments on discharge capacity, OCV, and discharge/charge resistances are performed using hybrid pulse power characterization and direct current internal resistance (DCIR) measurements over the full state-of-charge (SOC) range. The experimental results of the LTO rechargeable cell highlight the importance of correct selection of internal parameters that can reduce EECM errors. This study clearly provides experimental procedures, internal parameters results, and EECM guidelines for adaptive control-based SOC estimation for LTO rechargeable cells.