• Title/Summary/Keyword: chromium hexavalent

Search Result 167, Processing Time 0.021 seconds

Relationship between Chromium Concentration in Male Rats Fluids and Erythrocytes after Inhalation Exposure of Soluble Hexavalent Chromium Compound (수용성 6가크롬을 흡입 노출 시킨 랫드의 체액과 적혈구중 크롬간의 관련성 연구)

  • Kim, Kwang-Jong;Kim, Hyun-Young;Yoon, Soo-Jong;Lee, Eun-Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2001
  • The goal of this study was to evaluate the relationship between ambient hexavalent chromium concentration and the concentration of the chromium in whole blood, plasma, erythrocytes, and its urinary excretion of male rats after inhalation exposure of sodium chromate during 1, 2, and 3 weeks. 1. Differences of mean chromium concentration in urine, whole blood, erythrocytes, and plasma of male rats exposed to sodium chromate by exposure level were statistically significance, respectively. 2. At low and high exposure groups, differences of mean chromium concentration in urine, whole blood, erythrocytes, and plasma of male rats by duration of inhalation exposure were statistically significance, respectively. 3. Ratio of whole blood chromium to plasma chromium increased with the increased duration of inhalation exposure of sodium chromate. 4. Ambient hexavalent chromium was positively and strongly correlated with in erythrocyte chromium, and also erythrocyte chromium was strongly correlated with in whole blood chromium. In conclusion, this study showed that chromium in erythrocyte increased with the increased exposure level and exposure duration, therefore this study suggests that chromium in erythrocytes is a good biological exposure index of the internal dose from exposure to soluble hexavalent chromium compound.

  • PDF

Ni-BASE ALLOY SYSTEMS AS ALTERNATIVE TO HEXAVALENT CHROMIUM (경질크롬도금 대체용 Ni계 합금도금 기술)

  • Chang, Do-Yon;Lee, Kyu-Hwan;Kwon, Sik-Chol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.11-11
    • /
    • 2003
  • Electroplated hexavalent chromium coatings have been used in many technical applications since it was invented by G.J. Sargent in 1920. Because of the environmental problems and health risks associated with the use of hexavalent chromium, there has been an extensive search for alternative coatings with properties such as corrosion resistance and wear resistance, at a reasonable cost. However there is no single substitute that meets all the desirable performance characteristics of chromium. Advanced techniques, such as alloy plating, electroless plating, trivalent chromium plating, plasma and thermal spray coating, PVD and ion implantation, have been applied for replacing hexavalent chromium plating.

  • PDF

Pretreatment Effect on the Analysis of Insoluble Hexavalent Chromium (전처리방법에 따른 불용성 6가 크롬 분석에 관한 연구)

  • Lee, Eun Jung;Roh, Jae Hoon;Won, Jong Uk;Chun, Mi Ryonng;Cho, Myung Hwa;Kim, Chi Nyon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.292-300
    • /
    • 1996
  • Hexavalent chromium($Cr^{+6}$) compounds are considered to be particularly hazardous, primarily because of the associated risk of allergic reaction and cancer. The analytic method of hexavalent chromium such as the s-diphenylcarba-zide(DPC) method and all ether previously used methods are often made uncertain due to significant interferences from organic components. This report can provide a technique for the more rapid and simple determination of total hexavalent chromium. than other currently using methods. The s-diphenylcarbazide method proposed by the U.S. National Institute for Occupational Safety and Health has low recovery rate(15.67 - 48.20%) due to interference, iron chloride and nickel chloride. A microwave oven technique has high recovery rate(about 70%) of insoluble hexavalent chromium. For the difference of ionic charges of $Cr^{+3}$-ethylenediamine tetraacetic acid(EDTA) chelate and $CrO_4{^{-2}}$, we could detect them simultaneously by ion exchanged high performance liquid chromatography. The confirmation of $Cr^{+3}$ and $Cr^{+6}$ were checked by fraction collector and flameless atomic absorption spectrometer. We observed that the small amount of hexavalent chromium is converted to trivalent chromium due to enhancement of chromium reduction by $Fe^{+3}$ or $Ni^{+2}$. As a result of this study, on the analysis of insoluble hexavalent chromium with microwave oven was used for, it may be better and more precise analysis after pretreatment by 2% NaOH-3% $Na_2CO_3$ and then analysis UV-spectrophotometer. It should be done for various studies on insoluble hexavalent chromium on the basis work environmental monitoring so called welding, painting etc.

  • PDF

Safety Evaluation of Water-soluble Chromium in Makeup Products (메이크업 화장품에서 수용성 크롬의 안전성 평가)

  • Jeong Hye-Jin;Joo Kyung-Mi;Kim Young-So;Park Jeong-Eun;Park Jin-Hee
    • Toxicological Research
    • /
    • v.21 no.1
    • /
    • pp.15-21
    • /
    • 2005
  • There is now a growing concern about the possible toxicity of heavy metals in cosmetics. Heavy metals can be used as cosmetic ingredients or may be present as low level impurities in some of the raw materials. Chromium derivatives are used as pigments in cosmetics. Chromium is essential and toxic trace elements. Chromium may cause skin allergy. However, the regulations related to cosmetic products give no limit values for Chromium. Hexavalent chromium is significantly more toxic than trivalent chromium. Hexavalent chromium may present a carcinogenic risk at high concentrations. Therefore, it is important to consider oxidation state of chromium when analyze chromium. The purpose of this study is to determine the concentrations of water-soluble trivalent and hexavalent chromium in samples of makeup products, and to assess the safety of cosmetics on the basis of animal sensitization tests using guinea pig. The present study of chromium in 48 makeup products of 12 manufacturers provides a basis for assessing safety of makeup products. Water-soluble hexavalent chromium was not detected in any product. Water-soluble trivalent chromium was detected in only 9 eye shadows out of 48 makeup products, and could not be quantified 3 out of 9 eye shadows. The highest level of water-soluble trivalent chromium was about 10 mg/kg in spite of 90,000 mg/kg of total chromium. The results of animal sensitization tests show that 200 mg/kg of trivalent chromium and 5 mg/kg of hexavalent chromium have no harmful effect. No cross-reaction among these metals was found. Accordingly, the concentrations of water-soluble chromium in makeup products seemed to be safe. The overall results indicate that chromium in cosmetics probably have no significant toxicological effects. However, It is necessary to set guidelines on the maximum permissible concentration of water-soluble chromium in cosmetics.

A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration (중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구)

  • Cheong, Hoe Kyeong;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

Environment-friendly Trivalent Chromate Treatment for Zn Electroplating (아연도금용 친환경 3가 크로메이트 표면처리기술)

  • Kim, Soo Won;Lee, Chul Tae
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.433-442
    • /
    • 2006
  • Hexavalent chromium passivation, as very effective anti-corrosion method, can not be used in the field of surface treatment for metal, any more. Throughout the world, this regulations which was applied to automotive industries will be extended to all industries including electronics industries in the near future. Therefore a new anti-corrosion method should be established without delay, and trivalent chromium passivation as an alternatives replace the hexavalent chromium passivation for the time being. This paper gives an overview of the currently available trivalent chromium passivation processes, and then it attempts to give an insight to develop a more effective trivalent chromium conversion coating process for possible substitution of the hexavalent chromium passivation process.

Extraction Characteristics of $Cr^{6+}$ from Aqueous Solutions with PC-88A, Alamine 336 and Aliquat 336 (PC-88A, Alamine 336 및 Aliquat 336에 의한 수용액중$Cr^{6+}$의 추출특성)

  • Kim Sung Gyu;Lee Hwa Young;Oh Jong Kee
    • Resources Recycling
    • /
    • v.11 no.6
    • /
    • pp.18-23
    • /
    • 2002
  • A study on the solvent extraction of hexavalent chromium from aqueous solutions has been investigated. The results showed that the extraction efficiency of chromium increased in proportion to extractant concentration. Aliquat 336 of quarternary amine effectively extracted hexavalent chromium and was superior to Alamine 336. And the stabilizers like polyhydric alcohols of octanol, decanol and dodecanol showed the similar effect fur prevention of third phase and a little promotion of extraction efficiency in comparison with non-use of polyhydric alcohols. On the other hand, in solvent extraction of hexavalent chromium from aqueous solutions, the hexavalent chromium was completely extracted at pH range lower than 7 with 1% Aliquat 336 as extractant and 5% decanol as stabilizer and the hexavalent chromium in extractant was completely stripped with 1M sodium hydroxide solution in the stripping step.

Cytotoxic Effect of Hexavalent Chromium on C6 Glioma Cells

  • Suk Seung-Han
    • Biomedical Science Letters
    • /
    • v.12 no.3
    • /
    • pp.261-265
    • /
    • 2006
  • Toxic effect of Hexavalent chromium $(CrO_3)$ on various cells and organs has been well recognized. However, the mechanism and degree of cytotoxicity of $CrO_3$ remain unclear. This study was performed to examine the cytotoxicity of $CrO_3$ on $C_6$ glioma cells by measuring cell viability. The XTT assay, one of the sensitive methods to determine the cell viability, was taken to examine the viability of glioma cells treated with $CrO_3$. In this study, not only decreased the number of glioma cells but morphologic changes of them were noted and cell viability decreased in a time and dose-dependent manner after treated with various concentrations of $CrO_3$ for 48hours. $IC_{90}\;and\;IC_{50}$ values in XTT assay were determined at $25{\mu}M\;and\;55{\mu}M$ $CrO_3$, respectively. These results suggest that Hexavalent chromium has a highly cytotoxic effect and has a time and dose-dependent cytotoxicity on $C_6$ glioma cells.

  • PDF

THE ASSESSMENT OF GENOTOXICITY AND LIPID PEROXIDATION IN CHROMIUM EXPOSED WORKERS

  • Maeng, Seung-Hee;Yu, Il-Je;Lee, Byung-Moo;Chung, Ho-Keun;Chung, Hai-Won
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05a
    • /
    • pp.67-67
    • /
    • 2002
  • According to the epidemiological studies in chromium workers, hexavalent chromium is associated with the risk of lung cancer. Genotoxicity such as chromosome aberration, and cellular oxidative damages by reactive oxygen species produced by hexavalent chromium exposure may play an important role in the carcinogenesis process.(omitted)

  • PDF

Welding Fume and Others from Welding Processes

  • Yoon, Chung-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.4
    • /
    • pp.320-328
    • /
    • 2004
  • A number of health hazards are generated in welding processes. In this paper, the characteristics of fumes and some other hazardous agents in welding are reviewed. Fumes in welding are generated by complex mechanism like physical ejection of particles, oxidation-enhanced vaporization, vaporization-condensation-oxidation, and spatter contribution. Fume generation rates could be described as a power function in a given process. Most of fume constituents was originated from consumables rather than base metal. The mass distribution for the welding fumes is unimodal and very small to penetrate respiratory system. So, almost fractions of fumes are classified into the respirable particulate mass. Total chromium contents in FCAW were similar to those from SMAW whereas hexavalent chromium concentrations in fume were similar to those produced from MIG welding fume. Hexavalent chromium was mostly soluble which was similar to the characteristic solubility of fume hexavalent chromium from SMAW.