• Title/Summary/Keyword: chromate

Search Result 147, Processing Time 0.025 seconds

Inducible Periplasmic Chromate Reducing Activity in Pseudomonas aeruginosa Isolated from a Leather Tannery Effluent

  • GANGULI, A.;TRIPATHI, A.K.
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.3
    • /
    • pp.355-361
    • /
    • 2001
  • A Chromate tolerant strain of Pseudomonas aeruginosa isolated from the effluent of a tannery showed significant enzymatic activity of chromate reduction. Cells grown in chromate-supplemented medium reduced 8 $\mu\textrm{g}$ chromate/mg protein/h in the presence of NADH/NADPH. The chromate reducing activity was inducible as cells pregrown in chromate showed higher chromate reduction. In contrast, the periplasmic fraction of cells gown in chromate reduce $75\%$ chromate in 4 h and the spheroplast fraction failed to do so, indicating that chromate reductase may be located in the periplasm. The presence of a 30 kDa protein in the periplasmic extracts of cells grown in the presence of chromate, but its absence of the protein in cells grown without chromate, points out a possible role of this protein in chromate reduction.

  • PDF

Chromate Removal from Wastewater using Micellar Enhanced Ultrafiltration and Activated Carbon Fibre Processes; Validation of Experiment with Mathematical Equations

  • Bade, Rabindra;Lee, Seung-Hwan
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.98-104
    • /
    • 2008
  • In this study, chromate and cetylperidinium chloride (CPC) removal from artificial wastewater was monitored by using micellar enhanced ultrafiltration (MEUF) and activated carbon fibre (ACF) adsorption hybrid processes. For the efficient chromate removal, molar concentration of the CPC should be five times that of chromate and it should be at least one critical micelle concentration (CMC). The MEUF was found to be effective in the chromate removal while ACF in the CPC adsorption to produce chromate and CPC free effluents. The chromate and CPC removal was 99.8% from MEUF-ACF process. Effluent chromate concentration was exponentially correlated with molar ratio of CPC to chromate and pH.

Simultaneous removal of dissolved TCE and chromate using micellar-enhanced ultrafiltration

  • 이율리아;김호정;백기태;김보경;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.413-416
    • /
    • 2003
  • Micellar enhanced ultrafiltration(MEUF) is a surfactant-based separtaion technique which can remove dissolved organics or multivalent ions from water. In this study, trichloroethylene(TCE) and chromate were simultaneouly removed using MEUF and cetyltrimethylammoniun chloride (CPC) was used as a surfactant. The removal efficiency of chromate was 99% and that of TCE was more than 80%. The presence of TCE or chromate did not affect removal efficiency of each pollutants because the predominat mechanism of TCE and chromate are different.

  • PDF

Remediation Groundwater contaminated with chromate using Micellar - enhanced ultrafiltration(MEUF)

  • 양지원;백기태;김보경
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.306-309
    • /
    • 2002
  • Micellar-enhanced ultrafiltration was investigated to remediate groundwater contaminated with chromate using a cationic surfactant, cetylpyridinium chloride (CPC). Removal of chromate was expressed as a function of molar ratio of CPC to chromate. With 10 molar ratio of CPC, removal efficiency of chromate was reached to over 99%. The rejection of CPC was 90% at 1 molar ratio, gradually increased as the molar ratio increased.

  • PDF

Removal of Chromate by White Rot Fungus, Inonotus cuticularis

  • LEE, DONG-HEUB;YONG-WON MIN;HAE-IK RHEE;JAE E. YANG;GIE-TAEK CHUN;YEON-HO JEONG
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.2
    • /
    • pp.292-295
    • /
    • 2002
  • A chromate-resistant white rot fungus, Inonotus cuticularis, abundant in oak trees, was isolated for chromate removal and detoxification of chromate. Inonotus cuticularis was also investigated for an optimal waste treatment system. The screened cells were able to reduce an initial chromate concentration of as high as 1,300 ppm. Cell growth kinetics showed that the optimum culture conditions in flasks were at $33^{\circ}C$ and pH 4.2. Furthermore, the cells were able to remove $54\%$ of the initial chromate by a two-stage operation based on the combination of a fermentor and airlift reactor.

복합오염물질제거를 위한 현장반응층 이용에 관한 연구

  • 조현희;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.168-171
    • /
    • 2003
  • This research was conducted to assess the performance of the mixed reactive materials with sand, iron filings, and HDTMA-bentonite for trichloroethylene (TCE) and chromate removal under controlled groundwater flow conditions. TCE and chromate removal rates with the mixtures of iron filing/HDTMA-bentonite were highest among four columns due to reduction by iron filings and sorption by HDTMA-bentonite. The greater capacity of the mixed iron filing/HDTMA-bentonite compared HDTMA-bentonite was due to an enhanced chromate reduction in addition to chromate sorption. The presence of chromate caused greater inhibition of TCE removal in the column with iron filings, while the presence of TCE caused less inhibition of TCE. Also, nitrate caused the decrease in TCE removal relative to chloride. Nitrate ions may also significantly affect TCE reduction rates by competing for electrons with the chlorinated compounds. The anion and co-existed contaminants competing effects should be considered when designed permeable reactive barriers (PRBs) composed of zero valent iron for field applications to remediate TCE and chromate.

  • PDF

The Effects of Drying Temperature on Chromate Treatment for Electroplated Zinc (전기 아연도금용 유색 크로메이트에 대한 건조 온도의 영향)

  • Su-Byung Jeon;Ji-Won Choi;Byung-Ki Son;Injoon Son
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.5
    • /
    • pp.289-298
    • /
    • 2023
  • In this study, the effect of drying temperature on characteristics of the trivalent chromate film on electroplated zinc was investigated. An zinc-electroplated iron specimen with a thickness of 5 ㎛ was used for chromate treatment. Chromate treatment was conducted in a solution diluted 10 times from a mixture of Cr(NO3)3·9H20 360 g/L, Co(NO3)2·6H2O 60 g/L, Na2SO4 60 g/L, NH4F·HF 25 g/L, and NaOH 20 g/L. The zinc electroplated specimen was treated using the chromate solution with pH 2.0 at 25 ℃ for 60 s. Subsequently, chromate-treated samples were dried in an electric furnace for 2h with temperature varied from 25 to 125 ℃. The corrosion rate increased with the increase in the drying temperature, and the surface morphology of the chromate-treated film was observed using FE-SEM. When the drying temperature changed, the color of the chromate film changed from green to yellow, and the thickness of the film changed from 362 to 241 nm, respectively. Additionally, corrosion resistance was evaluated via a salt spray test.

Properties of Materials for Treatment of Chromate in Industrial Wastewater (산업폐수중 Chromate이온 처리용 소재특성)

  • 전용진;김영준;홍영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.2
    • /
    • pp.103-107
    • /
    • 2004
  • This paper was studied the properties of materials for treatment of anionic chromate$(CrO4^{-2})$ in industrial wastewater. Ion exchange fiber, poly(acryloamidino diethylene diamine) with ion exchange and adsorption was prepared PAN fiber and diethylenetriamine under $AlC1_3$ catalyst at $120^\circ{C}$ and was analyzed $^{{13}/C-NMR$}$ and FT-IR spectroscopy. The maximum adsorption and the coordination of chromate on chelating fiber were analyzed FT-IR spectra. We proposed the coordination structure with inter/intramolecular bond.

  • PDF

Chromate Conversion Coating on 3D Printed Aluminum Alloys (3D 프린팅으로 제조한 알루미늄 합금의 크로메이트 코팅)

  • Shin, Hong-Shik;Kim, Hyo-Tae;Kim, Ki-Seung;Choi, Hye-Yoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.109-115
    • /
    • 2022
  • The demand for metal 3D printing technology is increasing in various industries. The materials commonly used for metal 3D printing include aluminum alloys, titanium alloys, and stainless steel. In particular, for applications in the aviation and defense industry, aluminum alloy 3D printing parts are being produced. To improve the corrosion resistance in the 3D printed aluminum alloy outputs, a post-treatment process, such as chromate coating, should be applied. However, powdered materials, such as AlSi7Mg and AlSi10Mg, used for 3D printing, have a high silicon content; therefore, a suitable pretreatment is required for chromate coating. In the desmut step of the pretreatment process, the chromate coating can be formed only when a smut composed of silicon compounds or oxides is effectively removed. In this study, suitable desmut solutions for 3D printed AlSi7Mg and AlSi10Mg materials with high silicon contents were presented, and the chromate coating properties were studied accordingly. The smut removal effect was confirmed using an aqueous desmut solution composed of sulfuric, nitric, and hydrofluoric acids. Thus, a chromate coating was successfully formed. The surfaces of the aluminum alloys after desmut and chromate coating were analyzed using SEM and EDS.

Effects of Surface Roughness on Atmospheric Corrosion of Galvanized Steel Sheets (아연도금 강판의 대기부식에 미치는 표면 거칠기의 영향)

  • 안진호;강성군;장세기
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.6
    • /
    • pp.307-316
    • /
    • 1998
  • The effects of surface roughness on chromate conversion coating and the corrosion behavior of galvanized steel sheets were investigated. Surface roughness was differently given to the galvanized steel sheets tested and these were then chromated. Accelerated corrosion test was conducted under the condition of $30^{\circ}C$, 90%RH with flowing 200ppm $SO_2$ gas. The galvanized steels were also exposed to urban environment for 5 weeks. The corrosion rates were measured by weight gain method. The distribution of chromate film and corrosion product on the coating were examined which SEM/EDS. The chromate film formed preferentially at the convex sites rather than at the concave sites on the surface. The corrosion products were found at the concave sites where the chromate film formed rarely. The corrosion product on the coating were found at the concave sites where the chromate film formed rarely. The corrosion rates increased slightly with the surface roughness in accelerated corrosion test but significantly in field test.

  • PDF