• 제목/요약/키워드: chlorine-hypochlorite

검색결과 66건 처리시간 0.022초

Effects of hypochlorite exposure on morphology and trace organic contaminant rejection by NF/RO membranes

  • Simon, Alexander;Nghiem, Long D.
    • Membrane and Water Treatment
    • /
    • 제5권4호
    • /
    • pp.235-250
    • /
    • 2014
  • The impacts of membrane degradation due to chlorine attack on the rejection of inorganic salts and trace organic contaminants by nanofiltration (NF) and reverse osmosis (RO) membranes were investigated in this study. The rejection of trace contaminants was examined at environmentally relevant concentrations. Changes in the membrane surface morphology were observed as a result of chlorine exposure. A small increase in rejection was consistently observed with all four membranes selected in this study after being exposed to a low concentration of hypochlorite (100 ppm). In contrast, a higher concentration of hypochlorite (i.e., 2000 ppm) could be detrimental to the membrane separation capacity. Membranes with severe chlorine impact showed a considerable decrease in rejection over filtration time, possibly due to rearrangement of the polyamide chains under the influence of chlorine degradation and filtration pressure. The reported results indicate that loose NF membranes are more sensitive to chlorine exposure than RO membranes. The impact of hypochlorite exposure (both positive and negative) on rejection is dependent on the strength of the hypochlorite solution and is more significant for the neutral carbamazepine compound than the negatively charged sulfamethoxazole.

잔류염소 측정용 전기화학센서의 유효성 (Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement)

  • 김홍원;정남용
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

염소-차아염소산 용액에 의한 저항성 금 정광으로부터 Gold-silver 용출 (The Leaching of Gold-silver from Refractory Gold Concentrate by Chlorine-hypochlorite Solution)

  • 조강희;김봉주;오스지;최승환;최낙철;박천영
    • 한국광물학회지
    • /
    • 제25권3호
    • /
    • pp.123-130
    • /
    • 2012
  • 염소-차아염소산 용액을 소성정광에 적용하여 gold와 silver를 효과적으로 용출시키고자 하였다. 염소 : 차아염소산 혼합비율 1.5 : 1, 그리고 NaCl 농도를 1 M으로 적용하였을 때 Au 용출율은 겨우 75%와 81%이였다. 그러나 광액농도를 1%로, 그리고 용출온도를 $65^{\circ}C$로 적용하자 Au 용출율이 100%에 도달되었다. 왕수분해 및 염소-차아염소산 용출 고체 잔유물을 XRD분석을 실시한 결과 석영이 관찰되었다. 따라서 석영 속에 함유된 gold는 염소-차아염소산으로 용출시키지 못할 것으로 사료된다. 따라서 석영 속의 gold를 용출시키기 위해서는 더 작은 미립자로 전처리하거나 더 강력한 산화제를 적용해야 할 것이다.

Effect on Colony Growth Inhibition of Soil-Borne Fungal Pathogens by Available Chlorine Content in Sodium Hypochlorite

  • Lee, Sung-Hee;Shin, Hyunman;Kim, Ju-Hyoung;Ryu, Kyoung-Yul;Kim, Heung Tae;Cha, Byeongjin;Cha, Jae-Soon
    • The Plant Pathology Journal
    • /
    • 제35권2호
    • /
    • pp.156-163
    • /
    • 2019
  • Our study investigated the available chlorine content, contact time and difference among strains of each pathogen for sodium hypochlorite (NaOCl) to control chemically against soil-borne fungal pathogens, such as Phytophthora rot by Phytophthora cactorum, violet root rot by Helicobasidium mompa, and white root rot by Rosellinia necatrix, causing die-back symptom on apple trees. As a result, the colony growth of Phytophthora cactorum was inhibited completely by soaking over 5 s in 31.25 ml/l available chlorine content of NaOCl. Those of H. mompa and R. necatrix were inhibited entirely by soaking over 160 s in 62.5 and 125 ml/l available chlorine content in NaOCl, respectively. Also, inhibition effect on available chlorine in NaOCl among strains of each soil-borne pathogen showed no significant difference and was similar to or better than that of fungicides.

PCBs의 스크랩으로부터 Au 용출과 회수 (The Leaching and Recovery of Au from Scrap of PCBs)

  • 유돈상;박천영
    • 한국지구과학회지
    • /
    • 제35권4호
    • /
    • pp.259-266
    • /
    • 2014
  • 폐 PCBs의 스크랩으로부터 염소-차아염소산염 용액을 이용하여 Au와 Ag를 친환경적이고 효과적으로 용출시키고자 하였다. PCBs에 Cu, Sn, Sb, Al, Ni, Pb, Au 등과 같은 유용금속이 함유되어 있는 것을 EDS 분석으로 확인하였다. 최대 Au 용출율은 1%의 광액농도, 2:1의 염산:차아염소산나트륨 그리고 2 M의 NaCl 농도조건이다. Au 회수율이 가장 높은 메타중아황산나트륨 농도는 3 M에서였다. 염소-차아염소산염이 폐 컴퓨터에 함유되어 있는 Au와 Ag를 효과적으로 용출시킬 수 있는 용매제 임을 그리고 메타중아황산나트륨이 Au를 간단하게 침전시킬 수 있는 첨가제임을 확인하였다.

Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance

  • Shao, P.;Kurth, C.J.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.69-81
    • /
    • 2013
  • The pH-dependent inter-conversion of the three free chlorine species ($Cl_2$, HOCl, OCl-) present in the aqueous hypochlorite solution was theoretically investigated. Each species was found overwhelmingly present in a characteristic pH range. Hypochlorite treatment of the polyamide membrane was carried out over these pH ranges and various membrane responses were observed. As pH is less than 8, membrane tends to be N-chlorinated by $Cl_2$ and HOCl, and N-chlorinated membrane showed reduced water permeance and salt rejection. As pH rises to 10-12, $OCl^-$ appears to be the dominating chlorine species. Membrane hydrolysis was found to well interpret the improved water permeance and salt rejection. When the pH is between 8-10, both N-chlorination and hydrolysis contribute to the response of the membrane, and the treated membrane showed improved salt rejection but reduced water permeation. Excessive hydrolysis occurred while the membrane was treated at pH 13 for the much stronger alkalinity.

흐름 주입 분석법에 의한 총 잔류염소의 정량 (Determination of Total Chlorine Residuals by Flow Injection Analysis)

  • 최용욱
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.430-437
    • /
    • 1999
  • 흐름주입 분석법(FIA)에 의한 간접 요오드화 UV 검출법으로 총 잔류염소를 신속하게 정량하는 방법을 연구하였다. FIA장치를 최적화하기 위해 용리액의 pH, 요오드화 이온의 농도, 혼합 및 반응코일의 길이,시료주입량 및 유속, 온도 및 검출파장에 대한 변화를 관찰하였다. pH 8.3에서 하이포아염소산 이온은 요오드화 이온을 선택적으로 산화시키고 자신은 염화이온으로 환원되었다. 방해이온을 제거하기 위한 가리움제로서 에틸렌다이아민이 가장 좋은 효율을 나타내었다. 하이포아염소산 이온의 검정곡선은 0.03-0.3 mg/L의 농도 범위에서 0.999이상의 직선성을 나타내었고, 검출한계는 0.007 mg/L이었다. 이러한 분석조건하에서 몇몇 전주근교 상수중 총 잔류염소의 농도를 정량하였다.

  • PDF

Electrogeneration of Hypochlorite Ions using a Dimensionally Stable Anode-Type (Ti/PtPd(10%)Ox) Electrode

  • Teresa Zayas;Miriam Vega;Guillermo Soriano-Moro;Anabella Handal;Miguel Morales;Leonardo Salgado
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.268-275
    • /
    • 2024
  • The study examined the electrogeneration of hypochlorite ions (ClO-) via electrolysis of aqueous NaCl solutions using a dimensionally stable anode-type (DSA-type) electrode based on platinum and palladium oxides supported on titanium mesh (Ti/PtPd(10%)Ox). The electrogenerated ClO- was quantified on the basis of the absorption band at 292 nm (Aλ = 292) of the UV-Vis spectrum. The effect of initial pH, concentration of NaCl, cell potential difference and electrolysis time were investigated in this study. The results showed that the electrolysis of aqueous NaCl solutions increases the solution pH up to high values (≥ 8.0) that favor the formation of ClO- over chlorine or hypochlorous acid. The hypochlorite concentration increases significantly at pH values > 7.0 and shows a linear trend with increasing NaCl concentration and with increasing cell potential difference. When the cell potential and NaCl concentration are held constant, the maximum hypochlorite value during electrolysis depends on both the cell potential and NaCl concentration. The Ti/PtPd(10%)Ox anode favors the production of hypochlorite ions, making this anode a promising material for use in electrochemical oxidation of wastewater via an indirect mechanism.

고농도 차아염소산나트륨 발생장치의 소독부산물 제어에 관한 연구 (A Study on Control Disinfection By-products in High Sodium Hypochlorite Generation)

  • 조해진;신현수;고성호
    • 대한기계학회논문집B
    • /
    • 제41권3호
    • /
    • pp.183-189
    • /
    • 2017
  • 상수도 소독공정에서 사용되고 있는 차아염소산나트륨은 일반적으로 유효염소 0.8 %로 생산되어 투입되고 있으며, 투입량이 많아질수록 소독부산물(Chlorate)이 증가되었고 수질기준을 초과하게 된다. 이에 따라 본 연구에서는 유효염소를 12%로 높인 차아염소산나트륨 발생장치의 전해조에 대해 소독부산물을 제어할 수 있도록 양극수 pH를 조절하였다. 실험결과 전해조 내 양극수 pH를 4.2(일반적인 차아염발생장치 운전 pH)에서 1.53으로 조절함으로서 Chlorate 농도는 95% 이상 낮아진 것으로 나타났으며, 또한 낮은 전류가 인가됨에 따라 양극의 효율도 15% 개선되는 결과를 얻었다. 이 장치의 개발로 대용량 상수도에서도 안전한 차아염소산나트륨의 적용이 가능하여 소독공정의 안전성 향상에 기여할 것으로 기대된다.

Hydrazine 合成의 一考察 (A Consideration of Hydrazine Syntheses)

  • 이학기
    • 대한화학회지
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 1961
  • It is important to study hydrazine because of the development of new uses for its derivatives. The Rasching method is the only satisfactory one for synthesizing hydrazine; it involves the oxidation of ammonia by sodium hypochlorite in the presence of some such catalyst as gelatin. Calcium hypochlorite was substituted for the sodium hypochlorite particularly in this work, applying agar-agar as catalyst. The results of the experiments are as follow: 1. The yield is proportional to the mole-ratio of ammonia to available chlorine in calcium hypochlorite and about 60% is obtained when the ratio is 20. 2. Agar-agar can be used as a catalyst and its proper concentration in the solution is 0.005%. 3. Proper concentration of available chlorine in the reaction solution is 0.23 mole/l. 4. The most effective condition for the reaction is a temperature of $60{\sim}65^{\circ}C.$ maintained for $20{\sim}25min$. 5. The reaction takes place equally well in either an open or closed container. 6. When calcium hypochlorite is applied in place of sodium hypochlorite, the yield of hydrazine is increased as much as 17%. 7. The yield of hydrazine is decreased by eliminating the suspension of $Ca(OH)_2$ which results from the use of calcium hypochlorite. 8. When $Ca(OH)_2$ is added to Rasching process, the yield of hydrazine is raised normally. 9. The fact that some metal ions, such as $Cu^{++},$ inhibit the formation of hydrazine was proved. 10. The suspension of $Ca(OH)_2$ acted as a remarkable adsorbent for $Cu^{++}$ like gelatin. The suspension of $Ca(OH)_2$ which results from the use of calcium hypochlorite acts as a catalyst, absorbing metal ions, to increase the yield of hydrazine. So I think that calcium hypochlorite is a more efficient oxidant than sodium hypochlorite in hydrazine syntheses.

  • PDF