• Title/Summary/Keyword: chloride ion concentration

Search Result 301, Processing Time 0.023 seconds

Development of an Immobilized Adsorbent for in situ Removal of Ammonium Ion from Mammalian Cell Culture Media and its Application to a Mammalian Cell Bioreactor: I. Development of Immobilized Adsorbent System (동물세포 배양액으로부터 암모늄 이온의 동시제거를 위한 고정화 흡착제의 개발과 동물세포 배양 시스템에의 응용: I. 고정화 흡착시스템 개발)

  • 박병곤;민용원;전계택;김익환;정연호
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.404-410
    • /
    • 1998
  • Three types of adsorbents were developed by immobilizing synthetic zeolite, Philipsite-Gismonine, in alginate, cellulose acetate and dialysis membrane for the in situ removal of ammonium ion which inhibits growth and productivity of animal cells such as CHO cells producing tPA. Ammonium ion removal efficiency and cell growth promoting effect with various immobilized adsorbents were evaluated and the membrane type was selected as an optimal immobilized adsorbent. The experiments were then simulated by adding 8mM ammonium chloride and immobilized adsorbent in order to validate the removal effect under high density cell cultures. The results showed increase in maximum cell density by three times, in cell viability, and in tPA productivity by 40%. And it was found that the promoting effects were more significant in case of high ammonium ion concentration system. It was also found that the optimum addition time for immobilized adsorbents was 48 hr in the absence of ammonium chloride addition and 72 hr in the presence of ammonium chloride addition.

  • PDF

Kinetics and Mechanism of the Hydrolysis of Imidoyl Halides (Imidoyl Halide의 가수분해 반응메카니즘과 그의 반응속도론적 연구)

  • Tae-Rin Kim;Jin-Hee Kim;Byung-Doo Chang;Kwang-Il Lee;Ung-Cho Kim
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.1
    • /
    • pp.48-55
    • /
    • 1976
  • The rate constants of the derivatives of N-(2,4-dinitrophenyl)-benzimidoyl chloride were determined at various pH and a rate equation which can be applied over wide pH range was obtained. The reaction mechanism of hydrolysis of N-(2,4-dinitrophenyl)-benzimidoyl chloride which has not been studied carefully earlier in acidic and basic solution can be fullly explained by the rate equation obtained. The rate equation reveals that, beow pH 7.00, the hydrolysis of benzimidoyl chloride proceeds through $S_N2$ reaction to form a carbonium ion intermediate.Above pH 8.5, however, the hydrolysis proceeds through the $S_N2$ type reaction which depends on hydroxide ion and imidoyl chloride concentration. At pH 7.0∼8.5, two reactions occur competitively.

  • PDF

A Study for the Accelerated Chloride Diffusion Test of Concrete (콘크리트의 촉진염소이온 확산 시험법에 관한 연구)

  • 이용은;김진철;이찬영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.427-432
    • /
    • 1999
  • An electrci method for the rapid determination of chloride diffusion coefficient in concrete is proposed considering the electrical migration term in the Nernst-Plank equation. The experimental set-up for this method is basically that for PD index by Dhir, excluding some change in the experimental parameter values in consideration of reliability, simplicity and rapidity of the accelerated test method. Experimental results show that 30mm of specimen thickness, 10 volt of supplied potential, and 5M of chloride ion concentration are optimal

  • PDF

Assessment of the effect of sulfate attack on cement stabilized montmorillonite

  • Kalipcilar, Irem;Mardani-Aghabaglou, Ali;Sezer, Gozde Inan;Altun, Selim;Sezer, Alper
    • Geomechanics and Engineering
    • /
    • v.10 no.6
    • /
    • pp.807-826
    • /
    • 2016
  • In this study, aiming to investigate the effects of sulfate attack on cement stabilized highly plastic clay; an experimental study was carried out considering the effects of cement type, sulfate type and its concentration, cement content and curing period. Unconfined compressive strength and chloride-ion penetration tests were performed to obtain strength and permeability characteristics of specimens cured under different conditions. Test results were evaluated along with microstructural investigations including SEM and EDS analyses. Results revealed that use of sulfate resistance cement instead of normal portland cement is more plausible for soils under the threat of sulfate attack. Besides, it was verified that sulfate concentration is responsible for strength loss and permeability increase in cement stabilized montmorillonite. Finally, empirical equations were proposed to estimate the unconfined compressive strength of cement stabilized montmorillonite, which was exposed to sulfate attack for 28 days.

Influence of Temperature on Chloride Ion Diffusion of Concrete (콘크리트의 염화물이온 확산성상에 미치는 온도의 영향)

  • So, Hyoung-Seok;Choi, Seung-Hoon;Seo, Chung-Seok;Seo, Ki-Seog;So, Seung-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.71-78
    • /
    • 2014
  • The long term integrity of concrete cask is very important for spent nuclear fuel dry storage system. However, there are serious concerns about early deterioration of concrete cask from creaking and corrosion of reinforcing steel by chloride ion because the cask is usually located in seaside, expecially by combined deterioration such as chloride ion and heat, carbonation. This study is to investigate the relation between temperature and chloride ion diffusion of concrete. Immersion tests using 3.5% NaCl solution that were controlled in four level of temperature, i.e. 20, 40, 65, and $90^{\circ}C$, were conducted for four months. The chloride ion diffusion coefficient of concrete was predicted based on the results of profiles of Cl- ion concentration with the depth direction of concrete specimens using the method of potentiometric titration by $AgNO_3$. Test results indicate that the diffusion coefficient of chloride ion increases remarkably with increasing temperature, and there was a linear relation between the natural logarithm values of the diffusion coefficients and the reciprocal of the temperature from the Arrhenius plots. Activation energy of concrete in this study was about 46.6 (W/C = 40%), 41.7 (W/C = 50%), 30.7 (W/C = 60%) kJ/mol under a temperature of up to $90^{\circ}C$, and concrete with lower water-cement ratio has a tendency towards having higher temperature dependency.

Applicability of Colormetric Method for Estimation of Chloride Penetration in Concrete Structure (콘크리트의 염화물 침투 특성 평가를 위한 변색법의 적용성)

  • Kim Myung yu;Yang Eun Ik;Lee Kwang Gyo;Min Seok Hong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.798-801
    • /
    • 2004
  • Silver nitrate colored method that measure easily penetration depth of chloride ion has been used, recently. But, characteristics of silver nitrate colored method hasn't examined well. Therefore, we are aim to examine characteristics of colored method. According to experiment results, when the colored method was applied in concrete, it is reasonable that $AgNO_3$ solution more than 0.05N concentration was sprayed. Chloride concentration difference in colored parts was about 20ppm when $AgNO_3$ of two concentration (0.05N, 0.1N) in concrete was sprayed.

  • PDF

Modelling of chloride diffusion in saturated concrete

  • Tsao, Wen-Hu;Huang, Nai-Ming;Liang, Ming-Te
    • Computers and Concrete
    • /
    • v.15 no.1
    • /
    • pp.127-140
    • /
    • 2015
  • The process of chloride ingress in saturated concrete was presented by a previous study that used a mathematical model for the same as that concrete. This model is to be studied chloride ion diffusion which is considered as a chemical phenomenon and is to be represented the chloride diffusion process to be a nonlinear partial differential equation (PDE). In this paper, this nonlinear PDE is solved by the Kirchhoff transformation to render into a linear PDE. This linear PDE associated with initial and boundary conditions is also solved by the Laplace transformation to obtain an analytical solution. To verify the serviceability and reliability of this proposed method, the practical application should be supplied. The input parameters were cited from the previous study. The free chloride concentration profiles obtained by the analytical solution of mathematical model for saturated concretes after 24 and 120 hrs of exposure were compared with the previous study. The predicted results obtained from proposed method have a tendency with experimental results obtained by the previous study and trend toward numerical results approximated by finite difference technique.

A Exprimental Study on the Corrosion of Reinforcing Steel in a Coastal Concrete Structure due to the Attack of Chloride Ions (염분침투에 의한 해안 콘크리트 구조물의 철근부식에 관한 실험적 연구)

  • 안상섭;김은겸;신치범;조원일;이윤한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.263-268
    • /
    • 1997
  • One of the principal causes of the deterioation of coastal concrete structures is the corrosion of reinforcing steel induced by the attack of chloride ions. An experimental study was performed to investigate the distribution of concentration of chloride ions in a coastal concrete structure and to measure the half-cell potential of embedded steel by using the copper-copper sulfate reference electrode. Quantitative analysis showed that the concentration of chloride ion in the aqueous phase near the surface of embedded steel exceeded a threshold value for corrosion, 0.05% by weight in concrete. The absolute value of half-cell potential at some members of embedded steel was measured to be higher than 350mV, indicating that the probability of corrosion is more than 90%. The prediction on corrosion based on the experimental measurements was confirmed by the observation of corrosion on the surface of steel bars in the concrete core taken out of the concrete structure.

  • PDF

An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete (콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는 센서 세선 수의 영향에 관한 실험적 연구)

  • Lee, Hyun-Seok;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.143-152
    • /
    • 2014
  • In this study, the sensor response and sensitivity is experimented and analyzed quantitatively by the line numbers of chlorine ion reaction type corrosion sensor that is developed. The sensor response of the developed corrosion sensor is verified with properties of chlorine ion. The multilineal sensor is shown a large resistance change more than the single line sensor by damage of the sensor. And, the resistance change of sensor is as large as high concentration of NaCl aqueous solution, the sensitivity of multilineal sensor is higher than single line sensor's, and the depth of sensor's location is as large as the increasing of resistance change time (cycle). These results suggest that, the developed corrosion sensor could sense corrosion reaction, sensor sensitivity and change of resistance for chloride ion. Especially, It was judged that 7 line sensor was the most superior for monitoring chloride ion immigration into concrete.

Experimental Study on Deterioration Characteristics under Combined Exposure Conditions of Chlorides and Sulfates (염화물 및 황산염 복합환경 하에서의 열화특성에 관한 실험적 연구)

  • 오병환;인광진;강의영;김지상;서정문
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.771-776
    • /
    • 2001
  • Test results on the deterioration process of concrete under single and combined attacks of chloride penetration have been obtained. After test period of 52 weeks, it is found that the internally penetrated chloride ion contents are less in the single attacks of chloride than the combined attacks of chloride and sulfate. Both the diffusion coefficients and surface chloride concentration derived form the chloride profiles showed a time dependence. Also the performance of fly ash-blended cements was observed to be better than plain cements in retarding chloride attack. However it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF