• 제목/요약/키워드: chloride corrosion

검색결과 755건 처리시간 0.024초

Strength and durability of concrete in hot spring environments

  • Chen, How-Ji;Yang, Tsung-Yueh;Tang, Chao-Wei
    • Computers and Concrete
    • /
    • 제6권4호
    • /
    • pp.269-280
    • /
    • 2009
  • In this paper an experimental study of the influence of hot springs curing upon concrete properties was carried out. The primary variables of the investigation include water-to-binder ratio (W/B), pozzolanic material content and curing condition. Three types of hot springs, in the range $40-90^{\circ}C$, derived from different regions in Taiwan were adopted for laboratory testing of concrete curing. In addition, to compare with the laboratory results, compressive strength and durability of practical concrete were conducted in a tunnel construction site. The experimental results indicate that when concrete comprising pozzolanic materials was cured by a hot spring with high temperature, its compressive strength increased rapidly in the early ages due to high temperature and chloride ions. In the later ages, the trend of strength development decreased obviously and the strength was even lower than that of the standard cured one. The results of durability test show that concrete containing 30-40% Portland cement replacement by pozzolanic materials and with W/B lower than 0.5 was cured in a hot spring environment, then it had sufficient durability to prevent steel corrosion. Similar to the laboratory results, the cast-inplace concrete in a hot spring had a compressive strength growing rapidly at the earlier age and slowly at the later age. The results of electric resistance and permeability tests also show that concrete in a hot spring had higher durability than those cured in air. In addition, there was no neutralization reaction being observed after the 360-day neutralization test. This study demonstrates that the concrete with enough compressive strength and durability is suitable for the cast-in-place structure being used in hot spring areas.

서울市 一部 水道栓水中 重金屬에 관한 調査硏究 (A Study on Heavy Metals at the Consumer s Tap in Seoul)

  • Lee, Byung Mu
    • 한국환경보건학회지
    • /
    • 제10권2호
    • /
    • pp.41-51
    • /
    • 1984
  • This study was performed using samples collected at Myungryundong and at Reservoirs. The purpose of this study was to investigate the differences of water quality between tap and raw water, and to analyse drinking water quality by Fe, Zn from corroded galvanized steel pipe. Results were as follows 1. The older the pipe was, the higher the concentration of Ferrum and Zinc was (t-test : p<0.05). Ferrum and Zinc also exceeded the limits in the older galvanized steel pipe. I think that this comes from the corrosion of pipe. 2. Mercury, Arsenic, Cadmium, Lead, Chomium, Argentum and Aurum not detected in raw water were not detected in tap water. Cobalt, Bismuth and Molybudenum detected in raw water were not detected in tap water. I think that this comes from the quality of raw water, the result of water treatment and the improbability of detection of above metals in water delivery system. 3. Silicon measured 2.4698ppm in raw water, but it ranged from 0.4769ppm to 1.982 ppm in tap water. Manganese measured 0.0638ppm in raw water, but it ranged from 0.0026ppm to 0.0198ppm in 17cases(31%) out of 55samples in tap water. I think that this comes from the water treatment. 4. Aluminium not detected in raw water was found in 17 cases (31%) out of the samples (55cases). It may be considered as the use of coagulants $Al_2(SO_4)_3$. $18H_2O$ and PAC (Poly Aluminium Chloride). The concentration of copper in tap water was much higher in 2 cases(3.6%) out of the samples(55) than that of copper in raw water. I think that this may come from the use of ${CuSO}_4$, the preventive of algae growth, and the result of chlorination, but further study must be necoessary to support the proof.

  • PDF

증기양생이 고로슬래그 콘크리트의 압축강도에 미치는 영향 (Effect of Steam Curing on Compressive Strength of Slag Binder Concrete)

  • 임병훈
    • 한국산학기술학회논문지
    • /
    • 제18권8호
    • /
    • pp.338-343
    • /
    • 2017
  • 본 논문은 이산화탄소 배출저감 및 산업폐기물을 재활용하기 위한 일환으로 산업부산물인 고로슬래그 미분말을 사용하였다. 고로슬래그 미분말은 선철의 제련 시 부산물로서 발생하는 고온 용융상태의 고로슬래그를 물로 급냉 시켜 유리화한 것으로 반응성이 높아 시멘트 및 콘크리트용 혼화재료로 다양하게 사용되고 있다. 고로슬래그 미분말을 치환한 콘크리트는 수화발열속도 저감, 온도상승 억제, 장기강도 향상, 수밀성 증대에 의한 내구성 향상 및 염화물 이온 침투억제에 의한 철근의 발청 억제 등의 다양한 효과를 기대할 수 있다. 그러나, 재령 초기 낮은 압축강도로 인해 사용량이 적은 실정이다. 따라서, 본 연구에서는 고로슬래그 미분말을 치환할 경우 낮은 압축강도를 보완하기 위해 증기양생이 초기 강도 발현에 미치는 영향을 평가하였고, 압축강도, SEM, EDS, XRD와의 관계를 분석하여 콘크리트의 압축강도 발현특성을 검토하였다. 그 결과 고로슬래그 미분말을 30% 치환한 콘크리트가 가장 우수하였으며, 이는 증기양생에 의해 고로슬래그 미분말의 피막을 파괴하여 ettringite 및 C-S-H겔 등의 수화물을 생성함으로 압축강도에 영향을 마친 것으로 판단된다.

역삼투압 농축수와 메타카올린을 사용한 친환경 시멘트의 개발 (Development of Eco-friendly Cement using Reverse Osmosis Brine Water and Metakaolin)

  • 김태완;한기봉;김도형;서기영
    • 한국건설순환자원학회논문집
    • /
    • 제9권2호
    • /
    • pp.216-222
    • /
    • 2021
  • 해수 담수화 플랜트에서 배출되는 농축수의 새로운 활용방안을 모색하기 위한 실험이다. 본 연구에서는 염화이온 고정화 효과가 뛰어난 메타카올린을 주요 결합재로 하고 활성화제로 10%와 20%의 산화칼슘을 치환하였다. 그리고 정수(tap-water; TW)와 농축수(reverse osmosis desalination water; RW)를 혼합수로 사용하였다. 실험결과 RW를 사용한 mixture는 TW 보다 더 높은 압축강도를 보였다. 또한 낮은 물-흡수율과 높은 밀도를 나타내었다. RW를 혼합수로 사용한 mixture에서는 Friedel's salt라는 수화반응물질을 관찰할 수 있었다. 강재의 부식문제를 고려한다면 RW는 무철근 콘크리트, 벽돌, 경계석 등의 제품에 적용할 수 있을 것으로 판단된다. 본 연구를 통해 RW의 해양 방출이외에 새로운 활용방안을 제시한 것에 의미 있다고 생각된다.

수소 취성 시험 평가를 위한 수소 방출 방지용 비수계 아연(Zn) 도금 (Non-aqueous Zinc(Zn) Plating to Prevent Hydrogen Release from Test Specimens in Hydrogen Embrittlement Test)

  • 전준혁;장종관
    • 한국가스학회지
    • /
    • 제26권3호
    • /
    • pp.21-26
    • /
    • 2022
  • 아연은 인체에 유해한 카드뮴을 대체하여 금속재료에 수소가스가 침투하거나 금속재료 내부로부터 수소가 누출되는 것을 방지하기 위한 친환경 코팅 재료로 주목받고 있다. 일반적으로 수성 및 산성 분위기에서 수행되는 아연(Zn) 및 아연 합금의 전기도금은 낮은 쿨롱 효율, 부식 및 수소 누출과 같은 단점이 있어 산업적 이용이 어렵다. 본 연구에서는 염화콜린과 에틸렌글리콜을 이용하여 Deep-eutectic solvent를 합성하고 이를 용매로 사용하여 아연 도금용 전해질을 제조하여 STS 304 기판 위에 전기 도금하였다. 주사전자현미경(SEM)과 원자힘현미경(AFM)을 이용하여 표면 미세구조와 조도를 관찰하였다. X선회절분석(XRD)을 이용하여 도금 막의 결정구조를 분석하였다. 마지막으로 수소를 주입한 STS 304 기판에 최적화된 Zn 도금액을 코팅한 시료의 수소 방출 방지 효과를 분석하였다.

Utilization of Piper betle L. Extract for Inactivating Foodborne Bacterial Biofilms on Pitted and Smooth Stainless Steel Surfaces

  • Songsirin Ruengvisesh;Pattarapong Wenbap;Peetitas Damrongsaktrakul;Suchanya Santiakachai;Warisara Kasemsukwimol;Sirilak Chitvittaya;Yossakorn Painsawat;Isaratat Phung-on;Pravate Tuitemwong
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권6호
    • /
    • pp.771-779
    • /
    • 2023
  • Biofilms are a significant concern in the food industry. The utilization of plant-derived compounds to inactivate biofilms on food contact surfaces has not been widely reported. Also, the increasing negative perception of consumers against synthetic sanitizers has encouraged the hunt for natural compounds as alternatives. Therefore, in this study we evaluated the antimicrobial activities of ethanol extracts, acetone extracts, and essential oils (EOs) of seven culinary herbs against Salmonella enterica serotype Typhimurium and Listeria innocua using the broth microdilution assay. Among all tested extracts and EOs, the ethanol extract of Piper betle L. exhibited the most efficient antimicrobial activities. To evaluate the biofilm inactivation effect, S. Typhimurium and L. innocua biofilms on pitted and smooth stainless steel (SS) coupons were exposed to P. betle ethanol extract (12.5 mg/ml), sodium hypochlorite (NaClO; 200 ppm), hydrogen peroxide (HP; 1100 ppm), and benzalkonium chloride (BKC; 400 ppm) for 15 min. Results showed that, for the untreated controls, higher sessile cell counts were observed on pitted SS versus smooth SS coupons. Overall, biofilm inactivation efficacies of the tested sanitizers followed the trend of P. betle extract ≥ BKC > NaClO > HP. The surface condition of SS did not affect the biofilm inactivation effect of each tested sanitizer. The contact angle results revealed P. betle ethanol extract could increase the surface wettability of SS coupons. This research suggests P. betle extract might be utilized as an alternative sanitizer in food processing facilities.

고전류밀도 전해도금 공정에서 PEG 첨가 효과 (Effects of PEG addition as an additive for electroplating of Cu at high current density)

  • 강병재;윤준서;박종재;우태규;박일송
    • 한국표면공학회지
    • /
    • 제57권4호
    • /
    • pp.274-284
    • /
    • 2024
  • In this study, copper foil was electroplated under high current density conditions. We used Polyethylene Glycol (PEG), known for its thermal stability and low decomposition rate, as an inhibitor to form a stable and smooth copper layer on the titanium cathode. The electrolyte was composed of 50 g/L CuSO4 and 100 g/L H2SO4, MPSA as an accelerator, JGB as a leveler, and PEG as a suppressor, and HCl was added as chloride ions for improving plating efficiency. The copper foil electroplated in the electrolyte added PEG which induced to inhibit the growth of rough crystals. As a result, the surface roughness value was reduced, and a uniform surface was formed over a large area. Moreover, the addition of PEG led to priority growth to the (111) plane and the formation of polygonal crystals through horizontal and vertical growth of crystals onto the cathode. In addition, the grains became fine when more than 30 ppm of PEG was added. As the microcrystalline structure changed, mechanical and electrical properties were altered. With the addition of PEG, the tensile strength increased due to grain refinement, and the elongation was improved due to the uniform surface. However, as the amount of PEG added increased, the corrosion rate and resistivity increased due to grain refinement. Finally, it was possible to manufacture a copper foil with excellent electrical and mechanical properties and the best surface properties when electroplating was carried out under the condition of additives with Cl-20 ppm, MPSA 10 ppm, JGB 5 ppm, and PEG 10 ppm.

규불화염계 복합 조성물을 혼입한 콘크리트의 균열제어 및 내구성 (Durability and Crack Control of Concrete Using Fluosilicates Based Composite)

  • 윤현도;양일승;김도수;길배수;한승구
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.57-64
    • /
    • 2006
  • 콘크리트에 균열이 발생하면 구조물의 구조적인 결함, 내구성 저하, 외관손상 등을 유발하여 치명적인 손실을 초래하기 때문에 균열제어를 통한 내구성능의 증대가 필수적이다. 국내 콘크리트 구조물의 동향을 살펴보면 LCC개념에 비추어 구조물의 신축비용이 25%에 불과하고, 다양한 형태의 균열보수, 개수, 유지관리 및 폐기처분에 대한 비용이 75%를 차지함에 따라 구조물의 시공시 콘크리트의 균열발생과 시공 후 콘크리트 내 철근부식을 억제하는 기술이 요구된다고 할 수 있다. 본 연구에서는 1990년대 후반부터 인산(H3PO4) 및 불산(HF)을 제조하는 공정 중에 액상형태의 부산물로 회수되는 불화규산(H2SiF6)을 활용하여 안정한 액상형태로 제조되는 규불화염계 화합물에 의한 균열저감 특성과 내구성에 대한 검토를 수행한 결과, 규불화염계 무기 조성물의 첨가로 수밀성이 증진되어 치밀한 경화조직을 형성함으로써 경화 후 급격한 수분의 손실에 따른 경화수축이 억제되어 건조수축을 저감시키는 특성을 발휘하였다. 또한 수화온도 및 수축 저감에 의해 조기에 균열발생을 억제하고, 수밀성을 증진시킴으로써 중성화, 동결융해저항성 및 염소이온침투깊이에 있어서 무첨가 콘크리트에 비해 상당히 개선되는 효과를 확인하였다. 마지막으로, 콘크리트 변형이 크게 발생되는 복합열화 환경 하에서도 SWP-2에 의한 내구성 향상 효과가 확인되었다.

함침계 표면보호제에 의한 콘크리트 표면의 세공구조 변화 및 내구성 향상 (Improvement of Durability and Change of Pore Structure for Concrete Surface by the Penetrative Surface Protection Agent)

  • 강석표;김정환
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.125-132
    • /
    • 2006
  • 최근 들어 툭별한 물리적 방법을 사용하지 않고 내구성능이 저하된 콘크리트의 성능을 회복시키는 방법의 일환으로서 콘크리트 표면보호재에 대한 관심이 높아지고 있다. 표면보호는 직접적인 의미로서는 콘크리트 구조물의 표면을 보호하는 것뿐만아니라 다양한 열화요인의 침투를 억제함으로서 내부의 콘크리트 및 철근의 열화를 억제하여 콘크리트 구조물을 보호하게 된다. 이와 같은 표면보호재 중 함침계 표면보호재는 콘크리트 표면층의 공극에 충전 혹은 생성물을 석출시켜 치밀한 층으로 하느 충전계와 콘크리트 표면층의 외부 및 내부표면의 성질을 개선하는 표면계로 분류하는 것이 가능하다. 따라서 본 연구는 규플르오르화염을 주성분으로 하는 표면형 함침계 표면보호제 도포에 의한 콘크리트 표면의 세공구조의 변화 및 중성화, 염해, 화학적 침식 등의 내구성 향상을 실험실증적으로 검토함으로서 콘크리트 구조물의 내구성향상 방안을 제시하고자 한다. 그 결과, 표면보호제를 도포함으로서 모든 물시멘트비에서 도포전과 비교하여 전세공용적이 감소하고 있으며, 특히 50nm이상의 비교적 큰 세공경인 모세관공극의 용적이 감소함으로서 물흡수성, 중성화 저항성, 내황산성, 염소이온침투 저항성 등의 내구성 향상에 기여하는 것으로 나타났으며, 그 효과는 물시멘트비가 클수록 높게 나타났다.

모세관 전기영동 분석에서 계면 동전기 주입에 미치는 공존 이온의 영향 (Effect of Coexisting Ions on Electrokinetic Injection in Capillary Electrophoresis Analysis)

  • 이광우;전지영;이광필
    • 분석과학
    • /
    • 제9권1호
    • /
    • pp.35-42
    • /
    • 1996
  • 원자력 발전소의 배관 부식 등의 방지를 위하여 초순수에 첨가되는 고순도 시약 중의 미량 음이온 성분올 모세관 전기영동법에 의하여 정량하는 분석법을 개발하였다. 전해질은 5mM 크롬산염(pH=8.0)을, 캐필러리는 내경이 50 또는 $75{\mu}m$인 석영 캐필러리 내부를 염화 삼메틸 실란으로 처리하여 사용하였다. 기타 기기 조건은 전압 20kV, 검출은 254nm에서 간접 자외흡수법을 사용하였고 주요 정량 성분은 $Cl^-$, $NO{_3}^-$, $SO{_4}^{2-}$, $N{_3}^-$, $PO{_4}^{3-}$등이며, 시료 주입은 시료 농도가 1ppm 이상일 때는 유체역학적 주입법으로, 1ppm 이하는 계면 동전기 주입법을 적용하였다. 특히 본 연구에서는 시료 주입시 공존 이온의 영향을 조사한 결과 유체역학적으로 시료를 주입할 때는 시료 내 공존하는 음이온의 영향이 크게 없었으나, 계면 동전기적인 시료 주입시에는 공존하는 이온량과 전기영동적 이동도에 따라 분석 이온의 신호 크기가 크게 변함을 확인하였으며, 각 분석 성분 주입량, 즉 신호 크기는 시료 용액의 저항에 비례하였다. 따라서, 분석 이온보다 과량의 공존 이온 존재하에 계면 동전기 주입법으로 분석할 경우 시료 용액과 표준 용액의 전기 전도도 차이를 보상할 수 있는 표준물 첨가법 또는 내부 표준물법 등의 적절한 방법을 반드시 사용해야 한다.

  • PDF