• Title/Summary/Keyword: chiller

Search Result 337, Processing Time 0.031 seconds

A Study on Improvement of the Physical Properties of 4 Component Working Fluid in Gas Fired Absorption Chillers (가스흡수식 냉방기용 4성분계 작동매체의 물성 향상 연구)

  • Baek, Young-Soon;Oh, Young-Sam;Lee, Yong-Won;Park, Dal-Ryung;Koo, Ki-Kap
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.400-406
    • /
    • 1999
  • In an effort to obtain high efficiency in gas fired absorption chillers, a new working fluid has been developed with thc addition of the component of $LiNO_3$, LiCl and LiI to the conventional solution of $LiBr-H_2O$. The solubility and vapor pressure of the 4 component working fluid developed in this work were measured and compared to the results of $LiBr-H_2O$ solution. It was observed that there exists an optimal mole ratio of the inorganic salts in terms of solubility. The mole ratio of LiBr, $LiNO_3$ and LiCl was found to be around 5:1:1~2 in the $LiBr-LiNO_3-LiCl-H_2O$ mixture, and in the case of $LiBr-LiO_3-Lil-H_2O$ and $LiBr-Lil-LiCl-H_2O$ mixtures, the mole ratio of LiBr, $LiNO_3$ and Lil/ LiBr, LiI and LiCl were found to be around 5:1:1 and 5:1:0.5~1 respectively. The vapor pressure of the 4 component working fluid of the optimal mole ratio was increascd with adding the component of $LiNO_3$, LiCl and LiI except for $LiBr-LiNO_3-LiCl-H_2O$ mixture. The absorption capacity of $LiBr-LiNO_3-LiCl-H_2O$ mixture was obtained higher than that of $LiBr-H_2O$ mixture.

  • PDF

Geochemical Modeling of Groundwater in Granitic Terrain: the Yeongcheon Area (영천 화강암지역 지하수의 지화학적 모델링)

  • Koh, Yong-Kwon;Kim, Chun-Soo;Bae, Dae-Seok;Yun, Seong-Taek
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.4
    • /
    • pp.192-202
    • /
    • 1998
  • We investigated the geochemistry and environmental isotopes of granite-bedrock groundwater in the Yeongcheon diversion tunnel which is located about 300 m below the land surface. The hydrochemistry of groundwaters belongs to the Ca-HCO$_3$type, and is controlled by flow systems and water-rock interaction in the flow conduits (fractures). The deuterium and oxygen-18 data are clustered along the meteoric water line, indicating that the groundwater are commonly of meteoric water origin and are not affected by secondary isotope effects such as evaporation and isotope exchange. Tritium data show that the groundwaters were mostly recharged before pre-thermonuclear period and have been mixed with younger surface water flowing down rapidly into the tunnel along fractured zones. Based on the mass balance and reaction simulation approaches, using both the hydrochemistry of groundwater and the secondary mineralogy of fracture-filling materials, we have modeled the low-temperature hydrogeochemical evolution of groundwater in the area. The results of geochemical simulation show that the concentrations of Ca$\^$2+/, Na$\^$+/ and HCO$_3$and pH of waters increase progressively owing to the dissolution of reactive minerals in flow paths. The concentrations of Mg$\^$2+/ and K$\^$+/ frist increase with the dissolution, but later decrease when montmorillonite and illitic material are precipitated respectively. The continuous adding of reactive minerals, namely the progressively larger degrees of water/rock interaction, causes the formation of secondary minerals with the following sequence: first hematite, then gibbsite, then kaolinite, then montmorillonite, then illtic material, and finally microcline. During the simulation all the gibbsite is consumed, kaolinite precipitates and then the continuous reaction converts the kaolinite to montmorillonite and illitic material. The reaction simulation results agree well with the observed, water chemistry and secondary mineralogy, indicating the successful applicability of this simulation technique to delineate the complex hydrogeochemistry of bedrock groundwaters.

  • PDF

Synthesis of nanosized WC powder by Chemical Vapor Condensation Process (화학기상응축법에 의한 WC 나노분말의 합성연구)

  • ;;;Oleg V. Tolochko
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.04b
    • /
    • pp.45-45
    • /
    • 2002
  • 나노미터 크기의 결정립을 가지는 나노분말 및 나노복합분말의 제조와 특성에 관한 연구가 매우 활발하다. 나노복합분말의 제조방법에는 기상증발후 응축법, 화학응축법, 기계적합금법 등이 있으나, 고순도 및 균일한 크기분포의 분말과 응집되지 않은 분말의 제조 조건을 가장 잘 만족하는 방법은 화학기상응축법(Chemical Vapor Condensation; CVC)이다. 본 연구그룹 에서는 CVC밤법으로 이용하여 공구/금형재료에 가장 많이 사용되는 WC/Co 합금의 결정립을 n nm크기로 극미세화고자하는 연구을 진행하고 있다. 본 연구에서는 이들 WC/Co합금제조시 가장 중요한 출발분말인 나노크기 WC 분말의 제조와 그 특성에 관하여 연구하고자 하였다. 나노미터 WC분말을 제조하기 의한 전구체는 고상의 금속유기물인Tungstenhexacarbonyl$(W(CO)_6)$ 을 사용하였다. 수평관상로을 반응기로 사용하였으며, 노내의 온도을 500-110$0^{\circ}C$로 변화시 키면서 WC 분말을 합성하였다. 반응기 및 포집기 내부를 대기분위기, 상압의 Ar분위기, 진공 분위기로 변화시켜 압력 및 분위기의 영향을 조사하였다. 포집기는 상온 및 액체질소로 냉각 한 Chiller을 사용하였다. 형성분말의 상분석은 XRD로 조사하였으며, 형태 및 결정립크기는 TEM로 분석하였다. 반응온도 600 -1 OOO$^{\circ}C$의 온도범위에서 검은색의 WC 분말이 제조되었다. XRD 분석의 결과 로 제조된 분말은 상온에서 준안정상인 Hexagonal 구조의 $\gammar-WC_{1-x}$ 상이였으며, TEM 분석결 과 상압하에서는 약 30nm이하의 WC분말이 제조되었으며, 그 형태는 둥근 4각형의 모양을 지녔다. 감압하에서 진행한 경우 결정립의 크기는 8nm이하를 가졌다.곤가스로 산화를 방지하였고, 냉매로는 질소가스를 이용하였다. 제조된 분말을 기ㅖ적 분급법을 이용하여 분급하였고, 냉매로는 질소가스를 이용하였다. 제조된 분말을 기계적 분급ㅂ법을 이용하여 분급하였고, 압출에 이용된 분말은 250$\mu\textrm{m}$이하의 크기를 사용하였다. 또한 분말제조과정 중 형성되는 표면산화층을 제거하기 위하여 36$0^{\circ}C$에서 4시간동안 수소 환원처리를 행하였다. 제조된 분말은 열간 압출을 위하여 Aㅣcan에 넣고 냉간성형체를 만들고, 진공처리를 한 후 밀봉하여 탈가스처리를 하였다. 압출다이는 압출비가 각각 28:1과 16:1인 평다이(9$0^{\circ}C$)를 사용하여 각각 내경이 9, 12cm이고, 길이가 50, 30cm인 압출재를 제조하였다. 열간압출한 후의 미세조직을 광학현미경으로 압출방향에 평행한 방향과 수직방향으로 관찰하였고, 열간 압출재 이방성을 검토하기 위하여 X선 회절분석을 실실하여 결정방위를 확인하였다. 전기 비저항 및 Seebeck 계수 측정을 위하여 각각 2$\times$2$\times$10$mm^3$ 그리고 5$\times$5$\times$10TEX>$mm^3$ 크기의 시편을 준비하였다.준비하였다.전류를 구성하는 주요 입자의 에너지 영역(75~l13keV)에서 가장 높은(0.80) 상관계수를 기록했다. 넷째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all low in two aspects, named "the Nonsign

  • PDF

Effect of Different Stunning Time on Meat Quality of Broiler (육계 도축 시 전기 실신 시간이 육질에 미치는 영향)

  • Chae, H.S.;Ahn, C.N.;Yoo, Y.M.;Ham, J.S.;Jeong, S.G.;Lee, J.M.;Choi, Y.I.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.1017-1024
    • /
    • 2005
  • This study was investigated the effect of the length of stunning time on pH, water holding capacity(WHC), cooking loss(CL), meat color and incidence rate of blood spot in broiler carcass. One-hundred and forty broiler chickens were slaughtered by three different length of stunning times(5 sec., 8 sec., 11 sec.) with the same electrical frequency(255Hz) and 50 voltage in a commercial abattoir. The WBS values and cooking loss of breast muscle were increased with increasing the stunning time, while WHC of breast muscle were decreased. Lightness(L* value) and yellowness(b* value) scores of leg muscle and skin stunned with 50V, 255Hz, 8 sec, 11 sec. were higher than those of broilers stunned with 50V, 255Hz, 5sec(P<0.05). But, there was no significant difference in color on breast and wing muscle. In subjective evaluation, frequence of the first grade had a trend of being increased by extending the stunning time. There was only a few cases of PSE chicken with 0.02%, while blood spot was observed at the highest rate for the 5 sec. treatment. TBARS indicated that a longer length of stunning resulted in a higher rate of fat oxidation. This experiment demonstrated that the length of stunning time has a significant effect on meat quality and its stability during chiller storage.

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

The effect of suspension method on meat quality of Hanwoo (현수방법이 한우육질에 미치는 영향)

  • Hwang, I.H.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.427-436
    • /
    • 2004
  • The current study was conducted to determine the effect of suspension method on satisfaction level of Korean consumers and objective meat quality traits in Hanwoo longissimus dorsi(LD), triceps brachii(TB) and semimembranosus(SM) muscles. Eighteen Hanwoo steers were slaughtered and alternative sides were hung either by pelvic bone(TS) or Achilles tendon(Al). Sensory characteristics, WB-shear force, sarcomere length, water-holding capacity, saroomere length and cooking loss were determined after a 7-d chiller ageing. Higher carcass quality grade received significantly(p < 0.05) greater eating quality for LD, but the grade did not affect eating quality for both TB and SM. TS did not influence objective and subjective meat quality for TB, but that significantly(P < 0.05) improved eating quality for LD and SM. The most noticeable result was that when SM was tenderstretehed, eating quality was equivalent to that of nonna1ly hung LD. In relationship between objective and subjective meat quality assessments, eating qualty for LD had a significant(P < 0.05) relationship with intramuscular fat content, while that for SM was greatly(P < 0.05) related to saroomere length. The current study indicated that pelvic hanging was an effective way to improve eating quality both LD and SM, and carcass quality grades did not greatly reflect eating quality of SM and TB. The data also implied that instnunental measurements poorly estimated the satisfaction level of Korean conswners.

Study of Hydrodynamics and Reaction Characteristics of K-based Solid Sorbents for CO2 Capture in a Continuous System Composed of Two Bubbling Fluidized-bed Reactors (두 개의 기포유동층으로 구성된 연속장치에서 CO2 회수를 위한 K-계열 고체흡수제의 수력학적 특성 및 반응특성)

  • Kim, Ki-Chan;Kim, Kwang-Yul;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.499-505
    • /
    • 2010
  • In this study, hydrodynamics and reaction characteristic of K-based solid sorbents for $CO_2$ capture were investigated using a continuous system composed of two bubbling fluidized-bed reactors(1.2 m tall bed with 0.11 m i.d.). Potassium-based dry sorbents manufactured by the Korea Electric Power Research Institute were used, which were composed of $K_2CO_3$ of 35% for $CO_2$ absorption and supporters of 65% for mechanical strength. The continuous system consists of two bubbling fluidized-bed reactors, solid injection nozzle, riser, chiller, analyzer and heater for regeneration reaction. The minimum fluidizing velocity of the continuous system was 0.0088 m/s and the solid circulation rate measured was $10.3kg/m^2{\cdot}s$ at 1.05 m/s velocity of the solid injection nozzle. The $CO_2$ concentration of the simulated gas was about 10 vol% in dry basis. Reaction temperature in carbonator and regenerator were maintained about $70^{\circ}C$ and $200^{\circ}C$, respectively. Differential pressures, which were maintained in carbonator and regenerator, were about $415mmH_2O$ and $350mmH_2O$, respectively. In order to find out reaction characteristics of dry sorbents, several experiments were performed according to various experimental conditions such as $H_2O$ content(7.28~19.66%) in feed gas, velocity (0.053~0.103 m/s) of simulated gas, temperature($60{\sim}80^{\circ}C$) of a carbonator, temperature($150{\sim}200^{\circ}C$) of a regenerator and solid circulation rate($7.0{\sim}10.3kg/m^2{\cdot}s$). The respective data of operating variables were saved and analyzed after maintaining one hour in a stable manner. As a result of continuous operation, $CO_2$ removal tended to increase by increasing $H_2O$ content in feed gas, temperature of a regenerator and solid circulation rate and to decrease by increasing temperature of a carbonator and gas velocity in a carbonator.