PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구 (Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer)

  • 이상재;김대훈;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

흡수식 냉온수기 증발기용 전열관의 전열성능에 관한 연구 (A-Study on The Heat Transfer Performance of Evaporator Heat Transfer Tube for Absorption Chiller)

  • 권오경;차동안;윤재호;김효상
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.215-221
    • /
    • 2009
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer coefficient of thermoexcel notch tube increases about 79.6% and 45.3% at the film Reynolds number 69.7 compared with that of bare tube and low fin tube, respectively. The thermoexcel notch tube is show the best performance considering pressure drop and heat transfer coefficient.

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facility

  • Park, Byung-Kyu;Kim, Moo-Geun;Kim, Geun-Oh
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.17-26
    • /
    • 2001
  • Simulation was conducted using TRNSYS to evaluate the thermal performance of a facility. This facility has a condensing-type heat exchanger which is able to recover the latent energy for the purpose of reducing the heating energy in winter. The boiler and chiller are selected based on the annual peak loads and controlled to maintain the facility at the set temperature of 14~$17^\circ{C}$. Supplied energy by the boiler and recovered energy by the heat exchanger were calculated as a function of number of pass through heat exchanger, kind of fuel and hot water velocity. Simulation results show that about 20% of the total heating load can be recovered by the heat exchanger and the amount of latent heat is increasing with the number of pass. This means that the efficiency of the waste energy recovery system can be increased by using a condensing-type heat exchanger rather than a traditional sensible heat exchanger.

  • PDF

일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

Volatile Flavor Components as a Function of Electrical Stimulation and Chiller Aging for m. longissimus and biceps femoris of Hanwoo Beef

  • Yang, Jieun;Dashdorj, Dashmaa;Hwang, Inho
    • 한국축산식품학회지
    • /
    • 제39권3호
    • /
    • pp.474-493
    • /
    • 2019
  • The aim of the study was to evaluate the effect of an early post-mortem low voltage electrical stimulation (ES) to localized part of carcasses [m. longissimus lumborum (LL) and m. biceps femoris (BF)] and determined the tenderness and flavor compounds of Hanwoo steers (n=16). Carcasses were stimulated within 30 min post-mortem for 60s using 60 volts and muscles aged 2 and 14 d. Degradation of Troponin-T were accelerated by ES and degraded little faster in BF muscle than LL. Level of free amino acid content of stimulated and aged muscles was significantly (p<0.05) greater than control for both muscles. Totally 63 volatile compounds were identified by using SPME-GC. The ES treatment significantly (p<0.05) affected the level of 20 volatile compounds of LL as well 15 volatiles in BF muscle along with total amounts of ketones, sulfur containing, pyrazines and furans. Low voltage ES could be applied to reduce the aging time and improve volatile flavor development by increasing important desirable volatile compounds such as 2-methylpyrazine, 2,5-dimethylpyrazines and 2-acetylthiazole etc. due to released free amino acids from protein degradation.

수소충전소용 프리쿨러를 위한 수소가스 냉각에 관한 연구 (Study on Cooling of Hydrogen Gas for the Pre-Cooler in the Hydrogen Refueling Station)

  • 이경한;구경모;유철휘;황갑진
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.237-242
    • /
    • 2019
  • In the hydrogen refueling station (HRS), it is need the pre-cooling system (PCS) to limit the inside temperature ($85^{\circ}C$) of the onboard thank (700 bar) and to charge the hydrogen at short time (within 3 minutes) to fuel cell electric vehicle (FCEV). From those safety reasons, the temperature of hydrogen gas must be controled $-33^{\circ}C$ to $-40^{\circ}C$ in PCS. The cooling test of the gaseous ($N_2$, He, $H_2$) was carried out using heat exchanger (pre-cooler) by indirect cooling and direct cooling method. It was confirmed that the temperature of hydrogen gas had below $-40^{\circ}C$ at below $-75^{\circ}C$ of chiller temperature in direct cooling.

일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석 (Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System)

  • 김민지;도성록;최종민;이광호
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

Absorption cooling R&D in Europe

  • Kuhn, A.;Petersen, S.;Riebow, D.;Sahin, D.;Ziegler, F.
    • 대한설비공학회지:설비저널
    • /
    • 제33권3호
    • /
    • pp.50-57
    • /
    • 2004
  • This article reviews absorption cooling R&D in Europe from the viewpoint of fundamentals, cycle development and applications. The review contains information on R&D, predominantly of public projects in the field of sorption cooling. We report on research which is performed in Europe with some stress on Germany. There is progress in fundamentals, thermodynamic cycle design, and also applications. In the fundamentals part the discussion about thermodynamics, working pairs, and heat and mass transfer is reflected. Today's discussion on thermodynamic cycles is not very strong. Main focus is on special solid sorption cycles, compression­sorption hybrids, and open cycles, In the applications part the chilling business is the main issue. Some interest is given to the improvement of efficiency on and the adaptation to low temperature waste heat use, but the stress is on the use of solar energy as heat source. The area of heat pumping for heating purposes is less prominent but not at all negligible. Finally, industrial heat pumping involves the reverse cycle (heat transformer, heat pump type Ⅱ) also, but there is no significant activity.

  • PDF

A Methodology of Optimal Design for Solar Heating and Cooling System Using Simulation Tool

  • Lee, Dongkyu;Nam, Hyunmin;Lee, Byoungdoo
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.540-543
    • /
    • 2015
  • Solar energy is one of the most important alternative energy sources which have been shown to meet high levels of heating and cooling demands in buildings. However, the efficiencies to satisfy these demands using solar energy significantly vary based on the characteristics of individual building. Therefore, this paper is focused on developing the methodology which can help to design optimal solar system for heating and cooling to be in cooperated within the existing buildings according to their load profiles. This research has established the Solar Heating and Cooling (SHC) system which is composed of collectors, absorption chiller, boiler and heat storage tank. Each component of SHC system is analyzed and made by means of Modelica Language and Pistache tool is verified the results. Sequential approximate optimization (SAO) and meta-models determined to 15 design parameters to optimize SHC system. Finally, total coefficient of performance (COP) of the entire SHC system is improved approximately 7.3% points compared to total COP of the base model of the SHC system.

  • PDF

불화온실가스의 흡수단면적 측정을 통한 지구온난화지수의 추정 (Estimation of The Global Warming Potential of Fluorinated Green House Gases)

  • 김지혜;이정순
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.387-397
    • /
    • 2014
  • This work aims at estimating global warming potentials (GWP) of $CF_3Br$ and HFC-134a among green house gases. It has been reported that they have much higher GWP than $CO_2$ in the atmosphere. $CF_3Br$, halon 1301 which is well known to be a fire extinguisher, as one of the bromine-containing halons has been banned since 2003 due to destruction of ozone. HFCs, a kind of chiller which replaced chlorofluorocarbons (CFCs) are one of greenhouse gases regulated by the Kyoto Protocol. In this study, we produced GWPs of $CF_3Br$ and HFC-134a by calculating a life time and measuring an absorption cross section to obtain a radiative forcing (RF). Their absorption cross sections were measured by using Fourier-transformed infrared spectroscopy (FTS) with a gas cell filled with their certified reference materials at room temperature. As a result, the RFs of $CF_3Br$ and HFC-134a were 0.32 and $0.168Wm^{-2}ppb^{-1}$, respectively and the GWPs were calculated as 7989, 6076, 3903 for $CF_3Br$ and 3855, 1300, 656 for HFC-134a for the time horizon of 20, 100, 500 years, respectively. Overall, uncertainty of the estimated GWPs can be estimated to be about 2.6%. Our results were compared with those proposed by the previous studies (IPCC, 2007; WMO, 1999).