• 제목/요약/키워드: chemiluminescence immunochromatography

검색결과 3건 처리시간 0.014초

Chemiluminescence immunochromatographic analysis for the quantitative determination of algal toxins

  • Pyo, Dongjin;Kim, Taehoon
    • ALGAE
    • /
    • 제28권3호
    • /
    • pp.289-296
    • /
    • 2013
  • For the quantitative detection of algal toxin, microcystin, a chemiluminescence immunochromatographic assay method was developed. The developed system consists of four parts, chemiluminescence assay strip (nitrocellulose membrane), horse radish peroxidase labeled microcystin monoclonal antibodies, chemiluminescence substrate (luminol and hydrogen peroxide), and luminometer. The performance of the chemiluminescence immunochromatographic assay system was compared with high performance liquid chromatography (HPLC) detection. The detection limit of chemiluminescence immunochromatographic assay system is several orders of magnitude lower than with HPLC. The chemiluminescence immunochromatography and HPLC results correlated very well with the correlation coefficient ($r^2$) of 0.979.

Development of Novel Method for the Detection of Microcystin Using Chemiluminescence Immunochromatography

  • Pyo, Dong-Jin;Yoo, Ji-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.149-152
    • /
    • 2011
  • A new chemiluminescence immunochromatographic analysis system with high sensitivity and high reproducibility was developed for the determination of microcystins (MCs) in water. Horse radish peroxidase (HRP) labeled microcystin monoclonal antibody was used for the sensitive chemiluminescence detection. The chemiluminescence immunochromatographic analysis system was composed of microcystin LR (MCLR)-monoclonal antibody (mAb)-Horse Radish Peroxidase (HRP) conjugate, MCLR-BSA conjugate, luminol, hydrogen peroxide mixture solution, an immunochromatographic assay strip and luminometer. To detect the concentration of microcystins in water, we utilized one spot analysis of the strip instead of flow type analysis. We could detect the microcystins in water at a concentration as low as 9.45 pg/mL with the chemiluminescence (CL) detection.

B형 간염항원 및 항체 검사를 위한 화학발광면역검사법(CIA)과 면역크로마토그래피법(ICA)의 비교분석 (Comparison of chemiluminescence immunoassay (CIA) and immunochromatography assay(ICA) for Detecting HBsAg and Anti-HBs)

  • 김혜정;김은희
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3419-3424
    • /
    • 2013
  • B형간염표면 항원 및 항체(HBsAg와 anti-HBs)에 대한 검사 방법으로 화학발광면역검사법(CIA)을 포함한 면역검사법을 주로 사용하고 있으나 최근 간편한 면역크로마토그래피법(ICA)의 사용이 늘고 있는 추세이다. 본 연구에서는 CIA법을 이용한 정량검사법과 비교하여 신속검사인 ICA법의 민감도를 평가하고자 하였다. 대학병원에 간염검사를 의뢰한 검체 중 CIA법에서 양성 및 음성으로 나온 120 검체를 선정하여 ICA법으로 분석하였다. ICA법과 CIA법의 일치율은 항원 97%와 항체 90%로 나타났다. 항원검사의 ICA법 민감도, 특이도, 양성예측도, 음성예측도는 각각 97%, 100%, 100% 및 96.8%로 나타났으며, 항체검사는 각각 90%, 93.3%, 93.1% 및 90.3%로 나타났다. ICA법을 임상에서 사용 시 결과판독에 주의가 필요하며, 낮은 역가의 경우 검출되지 않는 제한점이 있으므로 예민도가 높은 다른 검사법을 이용하여 이중검사를 시행해야 할 것으로 사료된다.