• Title/Summary/Keyword: chemiluminescence emission intensity

Search Result 29, Processing Time 0.711 seconds

A Study of Characteristics of Combustion Radical and Exhausted Emissions in a Radiant Burner with Porous Ceramic Mat (다공성 세라믹 매트를 이용한 복사버너에서의 연소라디칼 특성과 배기배출물에 관한 연구)

  • Kim, Young-Su;Cho, Seung-Wan;Kim, Gyu-Bo;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.539-546
    • /
    • 2007
  • An experimental study was performed to investigate the characteristics of chemiluminescence in a radiant burner, varying the excess air ratio from 0.91 to 1.67 at firing rate 80.5 to 134.2 kW/m2 on $OH^*,\;CH^*,\;{C_2}^*$ in LNG-Air premixed flames. The signals from electronically excited states of $OH^*,\;CH^*,\;{C_2}^*$ were detected using a Intensified Couple Charged Detector (ICCD) camera. The measurements of exhausted emission were made to investigate the correlation between chemiluminescence and emissions. The chemiluminescence intensity was increased with increase of firing rate like characteristics of $NO_x$ emission. $NO_x$ also increased with increase of firing rate and excess air ratio. It is found that offset of firing rate is more dominant excess air ratio $NO_x$ emission. The maximum chemiluminescence intensity occurs near the stoichiometric excess air ratio or lean conditions in case of high firing rate and the maximum intensity occurs rather than rich conditions in case of relatively low firing rate. Amount of $NO_x$ emission is maximum at near stoichiometric excess air ratio, which is chemiluminescence intensity is maximum.

Characteristics of Chemiluminescence Intensities of Kerosene/Air Swirl Flames (케로신/공기 와류 화염의 화학발광 세기 특성에 관한 실험적 연구)

  • Lee, Hyeonjae;Seo, Seonghyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.485-496
    • /
    • 2015
  • The present study presents experimental results on the characteristics of emission spectra of kerosene/air swirl flames. The aviation fuel Jet A-1, which is used for the liquid rocket engines of the Korea Space Launch Vehicle, is used with three different swirlers to investigate the swirl strength effects. The emission spectra from the flames are measured with a spectrometer as the swirl strength and combustion air temperature are varied. Chemiluminescence intensities of $OH^*$, $CH^*$ and $C_2{^*}$ are identified from the spectra. The chemiluminescence intensities from the kerosene flames show sensitivity to the swirl strength and are affected by changes in the combustion air temperature. Among the three radicals of interest, $C_2{^*}$ show the most significant changes in chemiluminescence intensity with the swirl strength and equivalence ratio. The intensity ratios $I_{OH^*}/I_{CH^*}$ and $I_{C_2{^*}}/I_{CH^*}$ are adequate for indicating changes in the equivalence ratio with the air and fuel mass flow rates, respectively.

The Study on Flame Structure and NOx Emissions by Swirl Numbers and Fuel-Air Mixing Length in a Dump Combustor Gas Turbine (모형 가스터빈 연소기에서의 스월수와 혼합길이에 따른 화염구조와 NOx배출에 관한 실험적 연구)

  • Choi, Do-Wook;Kim, Gyu-Bo;Jeon, Chung-Hwan;Song, Ju-Hun;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.849-857
    • /
    • 2009
  • The experimental study was performed to investigate the effects of partial premixing, varying the equivalence ratio, mixing degree, swirl intensity, mixing length on the characteristics of flame structure and NOx emission. Experiments were conducted in a dump combustor at 1 bar using methane as fuel. Inlet air temperature was 570K. OH chemiluminescence images were acquired with an ICCD camera. As a result of the experimental investigation of characteristics of flame and NOx emission in partial premixed combustor, we can conclude the results as below. With the increase of swirl number, The flame length decreases and the flame width increases and it helps flame stabilization. It means that lean flammability limit is extended. With the increase of mixing of fuel-air length ratio, Flame goes to be stabilized and NOx emission and $OH^{\ast}$ intensity decrease. Through the comparison of preceding results, It is possible that the exhausted NOx emission from a gas turbine combustor will be able to predict through the $OH^{\ast}$ intensity.

Flame Structure and NOx Emission Characteristics in Laminar Partially Premixed $CH_4$/Air Flames;Effect of Premixing Degree (메탄/공기 층류 부분 예혼합화염의 화염구조와 NOx 배출특성;예혼합 인자의 영향)

  • Oh, Jeong-Seog;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.75-81
    • /
    • 2003
  • In this paper, the study of effects of flow variables on flame structure and NOx emission concentration was performed in co-axial laminar partially premixed methane/air flames. the objectives are to reveal its effect as parameters were varied and to understand the correlation between flame structure and NOx emission characteristics in the reaction zone. equivalence ratio(${\Phi}$), fuel split degree(${\sigma}$), and mixing distance(x/D) were defined as a premixing degree and varied within $1.36{\sim}3.17$(equivalence ratio), $50{\sim}100$(fuel split degree), and $5{\sim}20$(mixing distance). the image of $OH{\ast}$ and $CH{\ast}$, and NOx concentration were obtained with an ICCD camera and a NOx analyzer. additionally the maximum intensity location of $OH{\ast}$ chemiluminescence and $CH{\ast}$ chemiluminescence were measured to compare each flame structures. In conclusion flame structure and NOx emission characteristics were changed from diffused to premixed flame when mixing degree was on the increase. the main effect on flame structure and NOx production was at first equivalence ratio(${\Phi}$), and next fuel split degree(${\sigma}$), and finally mixing distance(x/D).

  • PDF

Influence of Changing Combustor Pressure on Combustion Characteristics and Reaction Zone in the Partially Premixed Flame with $CH_4$, $C_2H_4$ and $C_3H_8$ (부분 예혼합 화염에서 연소실 압력이 연료별($CH_4$, $C_2H_4$, $C_3H_8$) 연소특성과 반응영역에 미치는 영향)

  • Son, Je-Ha;Kim, Jong-Ryul;Choi, Gyung-Min;Kim, Duck-Jool
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.3
    • /
    • pp.33-40
    • /
    • 2011
  • Combustion experiments were conducted at three different fuels ($CH_4$, $C_2H_4$ and $C_3H_8$) to investigate the effects of combustor pressure (30 ~ -30 kPa) on combustion charateristics and reaction zone structure. Regardless of the fuels, emission index of CO (EICO) increased with decreasing combustor pressure, and EICO of $C_2H_4$ was mostly affected by changing combustor pressure at subatmospheric pressure. In order to observe reaction zone, $OH^*$, $CH^*$ and ${C_2}^*$ chemiluminescence intensity were measured. The sequence of the chemiluminescence intensity peak position was affected by chemical characteristics of fuels rather than changing combustor pressure. The emission zone thickness of $C_2H_4$ and $C_3H_8$, defined by the full width at half maximum (FWHM) of $CH^*$ intensity profile, were increased with decreasing combustor pressure. however, the thickness of $C_2H_4$ exhibited the opposite tendency due to the characteristics of the fuel as the bond structure.

The Flame Characteristics of Annular Combustor for Gas Turbine according to Combustor Length Ratio (가스터빈용 환형연소기의 연소실 길이비에 따른 화염특성)

  • Kim, Jaeyeong;Lee, Dongwon;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.127-130
    • /
    • 2015
  • The objective of this study is to investigate the real flame shape and characteristic of annular combustor. To identify the effects of combustor length ratio and equivalence ratio on the flame shape in annular combustion configuration, the employed parameters are combustor length ratio 0.6-1.0, equivalence ratio 0.7-1.1. The flame shape is visualized using DSLR camera and precision optic mirror. The flame intensity is analyzed by $OH^{*}$ chemiluminescence images with ICCD camera. CO and NOx emission performance is also examined using an exhaust gas analyzer. From the visualized images, it is confirmed that the different tendency appeared in combustor length ratio 0.6-0.7 and 0.8-1.0. The results of $OH^{*}$ chemiluminescence show that the flame intensity is the most uniform for equivalence ratio 0.9. The smaller equivalence ratio is, the less emission of CO and NOx will be in this investigation range.

  • PDF

Chemiluminescent Properties of Novel Biphenyl Analogue Blue Fluorophores

  • Cheon, Jong-Woo;Lee, Chil-Won;Geum, Neri;Gong, Myoung-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1202-1206
    • /
    • 2004
  • Novel naphthyl-containing biphenyl analogues were prepared by Suzki reaction for the chemiluminescent blue fluorophores. UV-Vis absorption, photoluminescence, chemiluminescence and CIE chromaticities were measured. The fluorophores displayed blue photoluminescence in solution with a maximum intensity around 378-415 nm. Sodium salicylate-catalyzed reaction of them with bis(2 carbopentyloxy-3,5,6-trichlorophenyl)-oxalate with hydrogen peroxide provided a strong chemiluminescent red light emission with wavelengths of 398-427 nm; these were similar to the photoluminescent spectra. The chemiluminescent intensity decayed exponentially and the glow of chemiluminescence, which was visible with naked eyes, was maintained for more than 4 h.

Detailed Local Chemiluminescence Measurement (OH*, CH* and C2*) and Nitrogen Oxides Emissions in Laminar Partially Premixed CH4/Air Flames (메탄/공기 층류 부분예혼합화염의 상세 라디칼(OH*, CH* 그리고 C2*) 정보와 배기매출물에 관한 실험적 연구)

  • Jeong Yong Ki;Oh Jeong Seog;Jeon Chung Hwan;Chang Young June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.263-270
    • /
    • 2005
  • An experimental study was performed to investigate the effects of partially premixing, varying the equivalence ratios from $0.79{\sim}{\infty}$, on NOx emissions and chemiluminescence of excited $OH^{\ast},\;CH^{ast}\;C_2^{\ast}$ radicals in laminar partially premixed flames. the signal from the electronically excited state of $OH^{\ast},\;CH^{ast}\;C_2^{\ast}$ was detected through a band pass filter with a photo multiplier tube, which are processed to the intensity ratio ($C_2^{\ast}/CH^{\ast},\;C_2^{\ast}/OH^{\ast},\;and\;CH^{\ast}/OH^{\ast}$) to reveal the correlation with local equivalence ratio. And measurements of NOx emission were made to investigate the relationship between visible flame appearance, chemiluminescence, and EINOX. The results demonstrated that (1) the flames at ${\phi}<1.59$ exhibited classical double flame structure, at ${\phi}>4.76$, the flames exhibited diffusion flame structure, and the intermediate flames at $1.59<{\phi}<4.76$ was a merged flame, (2) the $OH^{\ast}$ peak was located inside the $CH^{\ast}\;and\;C_2^{\ast}$ radical for all measured conditions and the emission intensity ratio of $C_2^{\ast}/CH^{\ast}\;and\;C_2^{\ast}/OH^{\ast}$ were identified as good marker for local equivalence ratio over a range of ${\phi}=0.79{\sim}1.2\;and\;CH^{\ast}/OH^{\ast}\;is\;0.79<{\phi}<1.9$. However, it was difficult to predict the equivalence ratio in partially premixed flames using this system for ${\phi}>2.38$, (3) the minimum NOX emission index (EINOx) is obtained for a equivalence ratio of 3.19 in the intermediate flames.

Chemiluminescence Properties of Polymeric Fluorophores Containing Distyrylarylene Unit

  • Lee, Hui U;Kim, Cheol Hui;Gong, Myeong Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.7
    • /
    • pp.727-731
    • /
    • 2001
  • Conjugated-non-conjugated alternating block copolymers containing distyrylarylene units were synthesized via Wittig reaction for chemiluminescent fluorophores. The polymers were differentiated from others by the presence of aromatic unit in the chromophoric block. When UV-VIS, photoluminescence and chemiluminescence spectra of these materials were compared with copolymers, a strong bathochromic effect was observed. A more pronounced red shift and higher chemiluminscence efficiency were observed in the polymer with anthracene ring. Sodium salicylate-catalyzed reaction of bis(2-carbopentyloxy-3,5,6-trichlorophenyl) oxalate with hydrogen peroxide produced a strong chemiluminescence from blue to yellow-green light emission with wavelength of 450-537 nm in the presence of the fluorophore. The chemiluminescent intensity decayed exponentially. The glow of chemiluminescence maintained more than l2 hr and was visible with the naked eye.

A study on preparation of luminol reagents for crime scene investigation (범죄현장 조사용 루미놀 시약의 제조법에 관한 연구)

  • Lim, Seung;Kim, Jung-mok;Jung, Ju Yeon;Lim, Si-Keun
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • Finding the blood left at a crime scene is very important to reconstruct or solve a criminal case. Although numerous reagents have been developed for use at crime scenes, luminol is the most representative. Bluestar Forensic has been used in recent years, but is expensive and cannot be stored after preparation. This study aims to develop a new luminol reagent that can be stored for a long period of time while maintaining the chemiluminescence intensity at the level of Bluestar Forensic. Because luminol dissolves well in aqueous alkaline solutions, the use of sodium hydroxide in the preparation of luminol reagents can promote the decomposition of hydrogen peroxide. Magnesium sulfate, sodium silicate, and potassium triphosphate have been used as hydrogen peroxide stabilizers. The effects of the addition of these substances on the chemiluminescence emission intensity and the storage period of the luminol reagents were confirmed. The addition of a hydrogen peroxide stabilizer was shown to have no significant affect on the chemiluminescence emissions intensity or stabilized pH of the luminol reagent during storage. It also greatly increases the shelf life of the reagents. The use of magnesium sulfate as a hydrogen peroxide stabilizer is the most appropriate. When sodium perborate is used instead of hydrogen peroxide as an oxidizing agent, there is no significant change in the sensitivity and chemiluminescence emissions intensity, but the storage period is shortened. However, after the reaction with blood, the pH of the mixed solution does not increase significantly, and is judged to be more suitable than a reagent made of hydrogen peroxide.