• Title/Summary/Keyword: chemicals controls act

Search Result 2, Processing Time 0.018 seconds

Technical Criterion of Safety Evaluation of Leakage Preventing Plates for Alleviating Space Shortage Between Chemical Storage Tank and Dike (화학물질 저장 탱크와 방류벽 사이의 공간 부족 개선을 위한 누출 방지판의 안정성 평가 기준)

  • Lee, Eunbyul;Kwak, Sollim;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.42-50
    • /
    • 2018
  • The Chemical Controls Act strictly regulates for the chemical companies to establish sufficient space between the liquid chemical tank and dike, but facilities already installed suffer from the space shortage between the tank and dike. Installing leakage preventing plates on the dike is considered as one of the economic solutions that can alleviate the space deficiency. However, there is no technical and reasonable criterion for the safety evaluation of the leakage preventing plate on the dike. In order to address this problem, we provide generalized and verified calculating equations that give maximum height and horizontal distance of leakage trajectories. Through the proposed equations, proper heights of the leakage preventing plates on the dike can be easily determined. In this study, new calculating methods are also developed to determine the impact force of the liquid to the leakage preventing plates. In addition, we performed the reactivity experiments between four corrosive liquid chemicals and two stainless steel materials that are candidate substances for the construction of the leakage preventing plate. The results of this study is expected to be applicable as a guideline in the design of safe dike and its leakage preventing plates.

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.