• Title/Summary/Keyword: chemical water quality

Search Result 1,528, Processing Time 0.03 seconds

The Comparison of Grid Resolutions using EFDC in Saemangeum Reservoir (격자 해상도에 따른 EFDC의 새만금호 모의)

  • Shin, Yu-Ri;Jang, Jeongryeil;Choi, Jung-Hoon;Cho, Young Kweon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.646-656
    • /
    • 2012
  • This study area was Saemangeum Reservoir in Korea and the applied model was Environmental Fluid Dynamics Code(EFDC). It was the same as the scenarios to the boundary and initial conditions except the resolutions of the model grids. The resolutions were about 800 and 2,000 cells. It was considered scenario 1 and 2. The model was performed to simulate the water temperature, salinity, water quality parameters such as dissolved oxygen(DO), chemical oxygen demand(COD), total nitrogen(T-N), and total phosphorus(T-P) at 2008. The simulation results of the two scenarios were reflected in the trend of observed data tolerably. However, water flow, water temperature, and salinity showed high confidence level at the scenario 1. The water quality items did not present high confidence level at the scenario 1 because which concept was considered to biochemical and physical processes. This result shows that grid resolution has an influence on the water transport and the effect is reflected directly shallow and narrow water area. But, the selection of grid resolution should be considered the purpose of model simulation and the process of target items.

Investigating Water Quality Data of Finished Water in Domestic Water Treatment Plants (1994-1998) (국내 정수장 정수 수질자료의 특성분석 (1994년-1998년까지 5년간 자료를 중심으로))

  • Yoon, Jeyong;Cho, Soonhaeng;Kim, Haeshim
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.431-443
    • /
    • 2000
  • Water quality data from water treatment plants in Korea during 1994-1998 were investigated to find out the characteristics of their non compliance. The number of plants surveyed were approximately 600 and the number of samples were over 30,000. Ten parameters of water quality selected in this study and their non compliance % (inside parenthesis) were as follows: Heterotrophic plate count (0.14%), Total coliforms (0.08%), $NH_3$-N (0.29%), $NO_3$-N (0.14%), THMs (0.02%), Turbidity (0.11%), Residual chlorine (5.5%), $KMnO_4$ consumption (0.04%), Hardness (0.03%), pH (0.07%). These levels of non compliance were compared to those obtained from WIDB (Water Industry Database, 1996) of American Water Works Association. This study strongly supported that small water plants (<10,000 tons/day) were more vulnerable in meeting the regulation criteria of many water quality parameters such as Heterotrophic plate count. Total coliforms, $NO_3$-N, THMs, Turbidity, Residual chlorine, $KMnO_1$ consumption, Hardness and pH. The $NH_3$-N concentration was especially high in winter and its violation was frequently found in the specific areas such as the downstream of major rivers. The average THMs concentration was surprisingly low, indicating $13{\mu}g/L$ which is 43% of US. Accordingly, these characteristics must be reflected in establishing the effective management of water quality policy of drinking water in Korea.

  • PDF

Monitoring of Water Quality Parameters using Spectroscopic Characteristics of River Water - Ulsan Area (하천 분광특성을 이용한 수질항목 모니터링 연구 - 울산 지역)

  • Hur, Jin;Kim, Mi-Kyung;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.863-871
    • /
    • 2007
  • Spectroscopic characteristics of river water from four major watersheds in the Ulsan area were measured to examine their potential for estimating water quality parameters. The total 176 river samples were collected from 44 sites of small streams within the watersheds during the year 2006. Spectroscopic characteristics investigated included protein-like fluorescence (FLF) intensity, fulvic-like fluorescence (FLF) intensity, terrestrial humic-like fluorescence (TLF) intensity, UV absorbance at 254 nm, and UV absorbance difference at 220 nm and 254 nm. Protein-like fluorescence intensity showed linear relationships with biochemical oxygen demand (BOD), chemical oxygen demand (COD), total phosphorous (TP) concentrations of the samples with the correlation of 0.784, 0.779, and 0.733, respectively. Due to the UV absorption characteristics of nitrate at 220 nm, UV absorbance difference at 220 nm and 254 nm was selected to represent total nitrogen (TN) concentration. Exclusion of some samples with PLF intensity higher than 5.0 improved the correlation between the UV absorbance difference and TN as demonstrated by the increase of the correlation coefficient from 0.392 to 0.784. Instead, for the samples with PLF intensity lower than 5.0, the highest correlation of TN was achieved with UV absorbance at 254 nm. The results suggest that PLF intensity could be used as the estimation index for BOD, COD, and TP concentration of river water, and as the primary screening index for the prediction of TN using UV absorbance difference. Some BOD-based water quality levels among the river water were statistically discriminated by the PLF intensity. Low p-values were obtained from the t-tests on the samples with the first level and the second level (p=0.0003) and the samples with the second and the third levels (p=0.0413). Our combined results demonstrated that the selected spectroscopic characteristics of river water could be utilized as a tool for on-site real-time monitoring and/or the primary estimation of water quality.

A Vegetation Purification System for Water Quality Improvement in Irrigation Reservoirs (저수지 수질개선을 위한 식생정화시스템)

  • 박병흔
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.87-95
    • /
    • 2000
  • A vegetation purification system was applied to improve water quality of Masan Reservoir in Korea, which was composed of constructed wetlands in series. Five different kinds of macrophytes were planted in each wetland. The system was operated with the condition of low concentrations and high hydraulic loadings. Removal efficiencies(%) of chemical oxygen demand(COD) , total nitrogen(T-N) and total phosphorus(T-P) in this system were 9.0, 12.8, 20.1% , respectively. and removal rates(g/$m^2$/d) were 1.9(COD), 0.34(T-N) and 0.05(T-P) . Comparing this system with other wetlands operated at low hydraulic loadings, average removal efficiencies were low but removal rates were relatively high. Accordingly, this system could be applied to imporve reservoir water quality, because removal rates are more important than removal efficiencies in case of reservoir water quality improvement . However, the removal efficiencies and rates of this system are less than those of the hydroponic biofilter method which is a kind of a constructed wetland and utilize root zones of emergent macrophytes for trapping pollutants. Therefore, it is recommended that this system should be modified to utilize root zones of emergent macrophytes enough to improve reservoir water quality more efficiently.

  • PDF

Influences on Concrete Quality of Residue Content Change of Chemical Admixtures (화학혼화제 고형분량 변동이 콘크리트 품질에 미치는 영향)

  • Kim, Jin-Cheol;Yoo, Hyeok-Jin;Kim, Hong-Sam;Jeong, Ho-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.457-463
    • /
    • 2014
  • The permitted limit, ${\pm}12%$, of the change in solid contents based on ASTM C 494 as an interim standard in Korea Expressway Corporation, can not reflect the kind of chemical admixture and the characteristics of solid content so that it differed depending on the admixture types. In this study, effect of cement concrete quality was investigated by solid changes which can be used chemical admixtures acceptance criteria. As a result of an evaluation of a change in the quality of concrete due to solid content, since Ligno-sulfonate based (LG) had a low water reducing ratio, the range of the change in solid content was great while Naphthalene sulfonated based (PNS) and Poly-carboxylate based (PC) High Range Water-reducing Admixtures (HRWR) had a high water reducing ratio, the permitted limit of the difference in solid content currently used as the acceptance criterion should be readjusted. As a result, it is found that the acceptable range must be managed within 10% and 5% when the solid contents less than 25% and more than 25%, respectively.

Development of Automatic Decision System for Cholrination Demand in Water treatment Plant (정수장내 염소요구량 자동결정시스템 개발)

  • Oh, Sueg-Young;Lee, Sung-Ryong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.807-812
    • /
    • 2000
  • Chlorination dosage in water treatment plant of field is determined by chlorination demand experiment through two or three hours after raw water was sampled in inflow. It is impossible to continuously control fer real time because sampled water is adapted chlorination dosage after water treatment process had been proceeded. Therefore in this study, we will design informal chlorination demand system this designed system will be experimented as to water quality and accuracy of control in various conditions. Throughout these. experimental results, we will revise the system and revised system is enable to optimal control of chlorination dosage. Finally, We have developed chlorination demand system, which can automatically determination of chlorination dosage to be determined according to variety of raw water quality inflow in water treatment plant.

  • PDF

Effects of Indirect Wastewater Reuse on Water Quality and Soil Environment in Paddy Fields (간접하수재이용에 따른 논에서의 수질 및 토양환경 영향 분석)

  • Jeong, Han Seok;Park, Ji Hoon;Seong, Choung Hyun;Jang, Tae Il;Kang, Moon Seong;Park, Seung Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.91-104
    • /
    • 2013
  • The objectives of this study were to monitor and assess the environmental impacts of indirect wastewater reuse on water quality and soil in paddy fields. Yongin monitoring site (YI) irrigated from agricultural reservoir and Osan monitoring site (OS) irrigated with treated wastewater diluted with stream water were selected as control and treatment, respectively. Monitoring results for irrigation water quality showed a significant statistical difference in salinity, exchangeable cation and nutrients. Pond water quality showed a similar tendency with irrigation water except for the decreased difference in nutrients due to the fertilization impact. Soil chemical properties mainly influenced by fertilization activity such as T-N, T-P, and $P_2O_5$ were changed similarly in soil profiles of both monitoring sites, while the properties, EC, Ca, Mg, and Na, mainly effected by irrigation water quality showed a considerable change with time and soil depth in treatment plots. Heavy metal contents in paddy soil of both control and treatment did not exceed the soil contamination warning standards. This study could contribute to suggest the irrigation water quality standards and proper agricultural practices including fertilization for indirect wastewater reuse, although long-term monitoring is needed to get more scientific results.

Water Quality Properties of Tributaries of Daechung Lake, Korea (대청호 유입지천의 수질 특성)

  • Shim, Moo Joon;Yoon, Jae Yong;Lee, Soo Hyung
    • Korean Journal of Ecology and Environment
    • /
    • v.48 no.1
    • /
    • pp.12-25
    • /
    • 2015
  • The tributaries of Daechung Lake play an important role in controlling eutrophication in the lake, which is used for agricultural purposes and as potable water. However, water quality properties were not extensively studied in the tributaries of Daechung Lake. The objectives of this study are to investigate spatial and temporal properties of water quality and to characterize streams which could threaten water quality of Daechung Lake. For this study, water samples were weekly or monthly collected from February 2014 to October 2014 in 9 streams. Water quality parameters analyzed in this study include biochemical oxygen demand (BOD), chemical oxygen demand (COD), total organic carbon (TOC), total nitrogen and phosphorus (TN and TP), suspended solids (SS), and chlorophyll a. Based on temporal distribution and principal component analysis, BOD, COD, TOC, SS, and TP were controlled by not only river discharge that increased during summer due to heavy rain fall, but also due to anthropogenic input (e.g., bridge construction and/or agricultural activity). Dilution is also one of the factors explaining TN and conductivity, both of which decreased with increased discharge. Generally, concentrations of contaminants (BOD, COD, TOC, TN and TP) in the tributaries were higher than those of Daechung Lake. However, pollution load indicated that only the main channel of Geum River and Sook Stream may largely influence lake waters, attributed mostly to their large volumes. This implies that the main channel and Sook Stream are the major influences on the water quality of Daechung Lake.

Physico-Chemical Characteristics of Aquacultural Discharging Water in Jeju Island (제주도내 양식장 배출수의 이화학적 특성 분석)

  • Kim, Man-Chul;Jang, Tae-Won;Han, Yong-Jae;Kim, Ju-Sang;Harikrishnan, Remasamy;Oh, Duck-Chul;Kim, Ki-Young;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.19 no.7
    • /
    • pp.943-948
    • /
    • 2009
  • Physical and chemical analyses of water discharged from 4 crowded farms (Sungsan, Pyosun, Wimi and Daejung) in Jeju island were performed from July, 2006 to Dec, 2006, and the result of the analyses showed that hydrogen ion concentrations (pH) for water discharged from Sungsan farm was 7.74, Pyosun was 7.68, Wimi was 7.68 and Daejung was 7.7. Salinity levels for Sungsan, Pyosun and Wimi had an average of 31$\sim$33 $^\circ$/$_\circ$$_\circ$ indicating characteristics of far distance areas, whereas that of Daejung was 28.81 %, which was far lower compared to regular sea water salinity. As the result of measuring dissolved oxygen (DO) for each area, each area showed first graded DO for each discharged water based on water quality level for each sea district. The result of measuring the temperature for discharged water showed that water temperatures for summer were 23$\sim$25$^\circ$C, and those for winter were 16$\sim$ 18$^\circ$C. Nitrogen concentrations for discharged water exceeded each sea area's water quality level in all farms. In the case of phosphate, its average value was 0.48 mg/l for Sungsan, 0.55 mg/I for Pyosun, 0.66 mg/I for Wimi, and 0.44 mg/l for Daejung, and chemical oxygen demand (COD) was shown to be 1.5 mg/l 1.8 mg/I, 1.6 mg/I and 2.3 mg/I for Sungsan, Pyosun, Wimi and Daejung respectively. For suspended solids (SS), the average concentration was 19.3 mg/I, 21.2 mg/I, 21.3 mg/I and 18.5 mg/I for Sungsan, Pyosun, Wimi and Daejung respectively. The results of physical and chemical analyses for discharged water in farms based on time showed that almost all items were shown to increase in the forenoon and decrease, overall, in the afternoon.

Pond System for Further Polishing of Constructed Wetland Effluent during Winter Season (연못을 이용한 동절기 인공습지 오수처리수의 추가 처리)

  • Yoon, Chun-Gyeong;Jeon, Ji-Hong;Kim, Min-Hee;Ham, Jong-Hwa
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.139-148
    • /
    • 2002
  • Pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent from December 2000 to June 2001. The wetland system used for the experiment was highly effective to treat the sewage during the growing season, but it was less effective and its effluent was still high to discharge to the receiving water body. Therefore, the wetland effluent may need further treatment to prevent water quality degradation. Pond system could be used to hold and further polish the wetland effluent during the winter season and ots feasibility was evaluated in this study. Additional water quality improvement was apparent in the pond system during winter season, and the pond effluent could be good enough to meet the effluent water quality standards if it is properly managed. Timing of the pond effluent discharge appears to be critical for pond system management because it is a closed system and whole water quality constituents are affected by physical, chemical, and biological pond environments. Once algae started to grow in mid-April, constituents in the pond water column interact each other actively and its control becomes more complicated. Therefore, upper layer of the pond water column which is clearer than the lower layer my need be discharged in March right after ice cover melted. In the experiment, water quality of the upper water column was markedly clear in March than ant other times probably because of freezing-thawing effect. The remaining lower water column could be further treated by natural purification as temperature goes up or diluted with better quality of wetland effluent for appropriate water uses. This study demonstrated the feasibility of pond system for subsequent management of wetland effluent during the winter season, however, more study is needed for field application.