• Title/Summary/Keyword: chemical testing

Search Result 831, Processing Time 0.038 seconds

Influence of sandblasting and primer on shear bond strength of resin cement to zirconia (샌드블라스팅과 프라이머가 지르코니아와 레진시멘트의 전단결합강도에 미치는 영향)

  • Lee, Jung-Haeng;Kim, Hyeong-Seob;Pae, Ah-Ran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.49-56
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of mechanical, chemical surface treatments on the zirconia-to-resin cement shear bond strength (SBS). Materials and methods: Eighty zirconia discs (Lava, 3M ESPE) and eighty zirconia/alumina composite (Zirace, Acucera) were embedded in an epoxy resin base. Zirconia discs were randomly divided in to four treatment groups(10 for each manufacturer): $50\;{\mu}m$ $Al_2O_3$ sandblasting (S50), $110\;{\mu}m$ $Al_2O_3$ sandblasting (S110), $50\;{\mu}m$ $Al_2O_3$ and primer (Z-Prime Plus, Bisco Inc) (S50z) and $110\;{\mu}m$ $Al_2O_3$ and primer (Z-Prime Plus) (S110z). Two resin-based luting cements (Calibra, Panavia F) were used to build 2 mm diameter cylinders onto the zirconia. After 24 h of storage in water, SBS testing was evaluate using a universal testing machine. Bond strength data were analyzed with one-way ANOVA, two-way ANOVA test and post hoc comparison was done using Tukey test (${\alpha}$ = .05). Results: Groups using primer showed the high shear bond strength. The groups that did not use primer presented lower shear bond strengths. Conclusion: The use of primer (Z-Prime Plus, Bisco) had significantly higher shear bond strengths.

SiO2 Behavior of MoSi2 Powders Containing SiO2 Synthesized by SHS Method (자전연소합성법으로 제조된 SiO2 첨가된 MoSi2 분말 내에서의 SiO2의 거동 연구)

  • Rha, Sa-Kyun;Jeon, Min-Seok;Song, Jun-Kwang;Han, Dong-Bin;Jeong, Cheol-Weon;Kim, Sung-Soo;Lee, Youn-Seoung
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.6
    • /
    • pp.559-564
    • /
    • 2011
  • In order to investigate the behavior of $SiO_2$ in the molybdenum silicide powders, crystal structure of these powders was measured by XRD, in addition, surface composition and surface phase (or chemical states) and microstructure were analysed by XPS and TEM, respectively. Mo-silicide powders containing $SiO_2$ were synthesized by SHS (Self-Propagating High-Temperature Synthesis) technique. In XRD result, according to increase of $SiO_2$ contents, the crystal structure for synthesized $MoSi_2$ powders was still typical $MoSi_2$ bct without any other phases. By XPS analysis, the surface of Mo and Si source powders was covered with $MoO_3$ and $SiO_2$, respectively, and the surface of synthesized $MoSi_2$ powder was also covered with $MoO_3$ and $SiO_2$, which were stable oxides at room temperature. However, according to increase of $SiO_2$ addition, $MoSi_2$ phase in XPS spectra decreased and $SiO_2$ phase increased relatively in synthesized $MoSi_2$ powders. From the results by XPS and XRD, we found that the existent $SiO_2$ has amorphous structure. In the microstructure, the small particulates of the synthesized products added $SiO_2$ agglomerated together to form larger clusters (from ~10 nm to ~1 ${\mu}m$). From TEM, XPS, and XRD results, we found that the out layer of agglomeration of synthesized $MoSi_2$ powder is surrounded by amorphous $SiO_2$.

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling (직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.393-401
    • /
    • 2009
  • Objective: The purpose of this study was to compare the shear bond strength (SBS) of brackets and microleakage of a tooth-adhesive-bracket complex bonded with a direct and an indirect bonding technique after thermocycling. Methods: Fifty non-carious human premolars were divided into two equal groups. In the direct bonding group a light-cured adhesive and a primer (Transbond XT) was used. In the indirect-bonding group, a light-cured adhesive (Transbond XT) and chemical-cured primer (Sondhi Rapid Set) were used. After polymerization, the teeth were kept in distilled water for 24 hours and thereafter subjected to thermal cycling (500 cycles). For the microleakage evaluation, 10 teeth from each group were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, and examined under a stereomicroscope. Fifteen teeth from each group were used for SBS testing with the universal testing machine and adhesive remnant index (ARI) evaluation. Data were analyzed using the Mann-Whitney U test, Chi-square test, and Fisher's exact test. Results: There were no statistical differences on SBS and microleakage between the two bonding techniques. The indirect bonding group had a significantly lower ARI score. Bracket failures were obtained between enamel-resin interfaces. Conclusions: The type of bonding technique did not significantly affect the amount of microleakage and SBS.

A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel (2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구)

  • Park, Ik-Keun;Park, Un-Su;Kim, Chung-Seok;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.439-445
    • /
    • 2001
  • The destructive method is reliable and widely used lot the estimation of material degradation but, it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. Ultrasonic nondestructive evaluation technique has been reported good to attain efficiency of measurement, high sensitivity of measurement, and rapidity and reliability of result interpretation. In this study, it was verified experimentally the feasibility of the evaluation of degraded 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $630^{\circ}C$ by high frequency longitudinal wave method investigating the change of attenuation coefficient by FFT analysis and wavelet transform. Because of carbide precipitation increase and spheroidization near grain boundary of microstructure to aging degradation, attenuation coefficient had a tendency to increase as degradation proceeded. It was identified possibly to evaluate degradation using the characteristics of high-frequency ultrasonics. Frequency dependence of ultrasonic attenuation coefficient to aging degradation appeared large, which made sure that attenuation coefficient is an important parameter for evaluation of aging degradation.

  • PDF

KCCH Medical Cyclotron Operation for Neutron Therapy and Isotope Production (1989) - A Technical Report - (중성자 치료와 동위원소 생산을 위한 KCCH 의학용 싸이클로트론의 운영 (1989))

  • Kim, Byung-Mun;Kim, Young-Sear;Bak, Joo-Shik;Lee, Jong-Du;Yoo, Seong-Yul;Koh, Kyung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 1990
  • After four years of planning, equipment acquisition, facility construction and beam testing, the KCCH cyclotron facility was put into operation in November1986. Now the KCCH cyclotron(MC-50) has been used for four years in neutron therapy and radioisotope production. Up to December 1989, 179(1852 sessions) patient have undergone neutron therapy. Radioisotope production for nuclear medicine use was started from March 1989 after extensive work to overcome target transport, target melting, beam diagnostic and chemical processing problems. This status report introduces the cyclotron facility, and the experiences of neutron therapy and isotope production with the MC-50 cyclotron. Besides, the operation results and the general troubles of the MC-50 during 1989 are summarized. Total operation time was 1252.5 hours. Four hundred hours were used for neutron therapy of 599 treatment sessions and 832.5 hours for radioisotope production. Total amount of produced raioisotope was 1695 mCi(Ga-67 : 1478mCi, Tl-201 : 107 mCi, I-123 : 25mCi, In-111 : 85mCi). Twenty hours were used for scheduled beam testing. In 1989, 882% of the planned operation were performed on schedule and this rats is improved remarkably compared to 71.0% in 1988.

  • PDF

EU Environmental Prohibition on Hazardous Substances and Its Impacts on International Trades of Korea Companies (국제환경규제 유해물질의 최근 동향 및 국내 수출기업에 미치는 영향)

  • Cho, Young-Dal;Byun, Sung-Won;Choe, Eun-Kyung;Kim, Sang-Hun
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Starting with textile products in the middle of 1990, environmental requirements on prohibition of hazardous substances in products have been led by EU member countries and expanded to electrical and electronic equipment with implementaion of RoHS (Restriction of the use of certain hazardous substances in electrical and electronic equipment) in 2006. Under EU REACH (Registration, Evaluation and Authorization of CHemicals), the concept of SVHC (Substances of Very High Concern) and resulting regulatory duties regarding it have been introduced to the supply chain of almost all industry sectors. In this technical review, kinds of hazardous substances, reasons for restrictions and related directives and regulations are reviewed with its influence on the international market. Suggestions are made how to cope with environmental regulations as well as mid-to-long term market strategy to secure global market competitiveness.

Magnetic Susceptibility depending on the Thermal Degradation of HK-40 Steel (HK-40강의 열화도에 따른 자화율의 변화)

  • Kim, Jeong-Min;Son, De-Rac;Park, Jong-Seo;Nahm, Seung-Hoon;Kim, Dong-Gyun;Han, Sang-In;Choi, Song-Chun;Ryu, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.22-28
    • /
    • 2004
  • Since the used materials of furnace heater tube with different kinds of thermal degradation were not commonly available, the HK-40 steel specimens were heat-treated isothermally at elevated temperature to simulate the microstructure at the service temperature. HK-40 steel specimens with five different aging time were prepared by isothermal heat treatment at $1050^{\circ}C$. The characteristics of the magnetic susceptibility have been investigated for the degradation evaluation of HK-40 steel. The magnetic susceptibility at room temperature increases as the extent of degradation of the materials increases. The variation of magnetic susceptibility was compared with the variation of tensile properties and Vickers hardness. To investigate the effect of the microsturctural change on the characteristics of tensile properties, hardness and magnetic susceptibility, the microstructures were examined by a scanning electron microscope(SEM) and the chemical compositions were analyzed by a energy spectrometer of SEM. As a result, the magnetic susceptibility method can be suggested as one of the nondestructive evaluation methods for the degradation of the HK-40 steel.

An Alysisan Experimental Study on the Evaluation Method of Clay Mineral Content through Aggregate Composition Analysis (골재의 성분분석을 통한 토분함량 평가방법에 관한 실험적 연구)

  • Kim, In;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.5
    • /
    • pp.565-575
    • /
    • 2024
  • This research was initiated to establish quality standards and testing methods for fine dust in aggregates, a component currently not regulated under the Korean Industrial Standards(KS) KS F 2527 for Concrete Aggregates. With limited existing research and no definitive quality or testing standards for fine dust, this study sought to provide a quantitative analysis of fine dust in aggregates and to set forth quality standards based on the dust content through a concrete performance evaluation. The experimental findings showed that the primary chemical constituents of the fine dust were aluminum oxide(Al2O3), iron oxide(Fe2O3), and silicon dioxide(SiO2). It was observed that increasing levels of fine dust in the aggregates led to higher values of the fine dust index(Al2O3+Fe2O3). This escalation in the fine dust index corresponded with an increase in the unit water content of the concrete and a consequent decline in compressive strength. Based on these observations, a maximum allowable limit for the fine dust index in aggregates was proposed at 23%. This limit was derived from the correlation between fine dust content and a 15% reduction in compressive strength of standard concrete specimens. The proposed evaluation method for the fine dust index based on its content in aggregates is expected to enhance concrete performance and ensure structural stability. This contribution to the field addresses a significant gap in the standards and provides a foundation for further research and standardization in the construction materials industry.

Determination of Application Rate of Composted Pig Manure for Wetland Rice (논토양에서 돈분톱밥퇴비 시용량 결정에 관한 연구)

  • Lee, Sang-Min;Ryu, In-Soo;Lee, Choon-Soo;Park, Yang-Ho;Um, Myung-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.2
    • /
    • pp.182-191
    • /
    • 1999
  • A study was conducted for the determination of application rate of pig-dung composted with sawdust (referred as pig manure hereafter) for wetland rice. The study involved the field experiments with the cultivation of rice under different rates of application of pig manure in combination of different rates of chemical fertilizers, in a wetland rice soil. The field experiment involved following treatments : (I) Without fertilizer, (II) Standard rate of chemical fertilizers based on soil testing($98-73-71kg\;ha^{-1}$ as $N-P_2O_5-K_2O$), (III) $2.1Mg\;ha^{-1}$ of pig manure $>+80-37kg\;ha^{-1}$ of $N- K_2O$ as chemical fertilizer(Less $N-P_2O_5-K_2O$ contained in the compost), (IV) $4.2Mg\;ha^{-1}$ of pig manure+ $62-3kg\;ha^{-1}$ of $N-K_2O$as chemical fertilizer(Less $N-P_2O_5-K_2O$ contained in the compost), (V) $10Mg\;ha^{-1}$ of pig manure+ Treatment(II), (VI) $20Mg\;ha^{-1}$ of pig manure +Treatment(II). Number of tillers in treatment (I) were higher than other treatments in tillering and panicle formation stage. After heading stage, treatments (V) and (VI) have higher number of tillers, but treatment (III) and (IV) have fewer number of tillers during all growing stage. Uptake of NPK in rice plants was higher in treatment (VI), but the efficiency of N, P and K was higher in treatment (I), (III) and (IV). The yield of unhulled rice were in order of tretments (VI)>(V)>(IV)>(II)>(III), although the difference was not statistically significant. Inorganic nitrogen, available P and exchangable K contents in soil were highest at tillering stage in all treatments and became low from panicle formation to harvest stage. Available P in soil was increased by the application of pig manure upto 20 cm depth. Exchangeable cation contents in 40 to 60 cm soil depth was much higher in treatment (VI) than in other treatments. Treatment (V) and (VI) showed much higher losses of N. $P_2O_5 $ and $K_2O$ than other treatment. Though treatment (VI) tended yield higher than in other treatments, showed lodging and occurrence of leaf and neck blast in this treatment. Yield of unhulled rice in treatment (IV) was not significant statistically and reduced nutritional losses. It is conclude that treatment (IV) seems to be the most reasonable one for the application of pig manure in combination of chemical fertilizers.

  • PDF