• Title/Summary/Keyword: chemical testing

Search Result 831, Processing Time 0.037 seconds

Analysis of Oxide Coatings Formed on Al1050 Alloy by Plasma Electrolytic Oxidation (Al1050 합금에 Plasma Electrolytic Oxidation으로 형성된 산화피막 분석)

  • Kim, Bae-Yeon;Lee, Deuk-Yong;Kim, Yong-Nam;Jeon, Min-Seok;You, Whan-Sik;Kim, Kwang-Youp
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.3
    • /
    • pp.295-300
    • /
    • 2009
  • The crystal structure of surface coatings on Al1050 alloy by PEO (Plasma Electrolytic Oxidation), were investigated. The electrolyte for PEO was Na-Si-P system solution. The main crystalline phase were $\gamma$-alumina and $\alpha$-alumina. Crystallinity was increased with applied voltage and applied time. The dominant crystalline phase were affected not only chemical composition of Al alloy substrate and electrolyte, but also the +/- ratio of applied voltage.

Development of an Electromagnetic Nondestructive Testing Method for the Prevention of Defects in Steam Generator Tubes at Nuclear Power Plant (원자력발전소 증기발생기 전열관의 결함발생 예방을 위한 전자기 비파괴 검사방법 개발)

  • Shin, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.83-85
    • /
    • 1996
  • Major cause of defects in steam generator tubes at nuclear power plant is the accumulation of magnetite and other byproducts of corrosion in the crevice gap between support plates and tubes. Since damaged tubes result in contamination of the secondary coolant by the radioactive primary coolant, they represent a safety hazard. Early detection of magnetite buildup is, therefore, imperative in order to take remedial measures such as chemical flushing. Although the eddy current testing is being used for the inspection of steam generator tubes, the interpretation of resulting signals is generally a difficult task. This paper uses the phase of sensor coil emf as the test signal to find a way of easier signal interpretation. Numerical study using FEM shows that the shape of resulting signal is good for identifying the relative position of the probe to the support plate, and for discreminating the different shapes and degrees of magnetite buildup in the crevice gap region.

  • PDF

Long Range Cylindrically Guided Ultrasonic Wave Technique for Inspection

  • Balasubramaniam, Krishnan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.364-371
    • /
    • 2003
  • In this paper, a review of the current status, on the use of long range cylindrically guided wave modes, and their interaction with cracks and corrosion damage in pipe-like structures will be discussed. Applications of cylindrically guided ultrasonic wave modes have been developed for inspection of corrosion damage in pipelines at chemical plants, flow-accelerated corrosion damage (wall thinning) in feedwater piping, and circumferential stress corrosion cracks in PWR steam generator tubes. It has been demonstrated that this inspection technique can be employed on a variety of piping geometries (diameters from 1 in. to 3 ft, and wall thickness from 0.1 to 6 in.) and a propagation distance of 100 meters or more is sometimes feasible. This technique can also be used in the inspection of inaccessible or buried regions of pipes and tubes.

Study on the 316LVM Stainless Steel for Surgical Implant Materials (생체용 316LVM 스테인레스강 개발에 관한 연구)

  • Sin, Myeong-Cheol;Lee, Gyu-Hwan;Lee, Han-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.71-82
    • /
    • 1982
  • The 316LVM stainless steel that is widely used in surgical implant has been studied. The objective of this study is to develop the domestic production of the surgical implant materials. In the work, the metalllirgical phenomena, physical and chemical properties and biocompatibility of the materials are investigated. According to the experimental observation, corrosion resistance is strongly depended on the -ferrite structure and passive film, and mechanical properties are mainly depended on the cold reduction ratio. The -ferrite structure is minimized in the 16.651 Cr and 14%Ni contents, and yield strength is 104 kg/mm$^2$ at 45% cold reduction. Biocompatibility is excellent in the mouse body test for six weeks.

  • PDF

Dynamic testing and health monitoring of historic and modern civil structures in Italy

  • Gattulli, Vincenzo;Lepidi, Marco;Potenza, Francesco
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.1
    • /
    • pp.71-90
    • /
    • 2016
  • The paper reports a wide overview of the scientific activities on Structural Health Monitoring (SHM) in Italy. They are classified on three different conceptual scales: national territory (macro); regional area (medium); single structure (small). In the latter case differences have been pointed out between permanent installation and short-term experimental campaigns. A particular focus has been dedicated to applications devoted to cultural heritage which have an important historic, strategic and economic value for Italy. Two specific cases, the first related to the permanent monitoring of an historical Basilica and the second regarding the dynamic testing of a modern structure, have been presented as a basis for a general discussion.

Introduction to the Applied Kinesiology, as a Yin-Yang Balance Based Approach (음양균형의학으로서의 응용근신경학(AK) 개요)

  • Yin, Chang Shik
    • Journal of TMJ Balancing Medicine
    • /
    • v.7 no.1
    • /
    • pp.24-31
    • /
    • 2017
  • Applied Kinesiology (AK) is an evaluation system on the functional balance and integration of the body. Functional aspects of the triad of health are evaluated through muscle testing to see if the balance and integration is in an optimal status or is influenced by a given environmental stimulation. Triad of health refers to the structural, chemical, and psychological aspects of the body. Muscle testing in AK is a functional neurological assessment of muscular response to a given environmental stimulation in a given individual. Meridian system and stomatognathic system as in TMJ balancing medicine serve as one of the theoretical basis of AK. This article reviews core concepts of AK, discusses yin-yang balance medicine perspectives and clinical applications of it.

  • PDF

Evaluation of Reliability for Welded thick steel joint (후판 강용접부의 신뢰성 평가)

  • 최원두;이영호;길두송;박상기
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.327-329
    • /
    • 2004
  • Reliability evaluation of the welded structure for industrial structures/facilities such as power plant and petro-chemical refinery facilities is very important, and especially the reliability diagnosis of the structure is based on the exact evaluation of materials properties. But, the conventional Pre-Qualification test had the difficulty of evaluating the real material properties in the field because the test was made on the specimen with the simulated welding for the in-field welding condition. Therefore, a continuous indentation technique was proposed for simple and non-destructive testing of in-field structures and for selective testing of local range such as heat affected zone and weldment.

  • PDF

A Study on the Evaluation Method for Thermal Lifetime Diagnosis of Insulating Material for Mold Transformer (몰드변압기용 절연재료의 열적 수명진단을 위한 평가법 연구)

  • Cheong, Jae-Weon;Park, Hong-Tae;Oh, Il-Sung;Seo, Jung-Min
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1000-1002
    • /
    • 1999
  • In this study, we were developed to provide a method for evaluating insulation systems for mold transformers with high-voltage ratings greater than 600V, in order to establish a uniform method for determining the temperature classification of mold transformer insulation system by testing rather than by chemical composition. Since these procedures are considered to be new, and have been tested exhaustively, further testing may prove the need for future revisions.

  • PDF

Failure Analysis of Austenitic Stainless Steel Pipe (오스테나이트계 스테인레스 강관에서의 손상해석에 관한 연구)

  • 이상율;이종오;이주석;조경식;조종춘;이보영
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.21-32
    • /
    • 1993
  • A cracking failure of a austenitic stainless steel elbow in a naphtha cracking line in a petrochenmical plant occurred, resulting in leakage of organic compound flowing inside the elbow. Due to the failure, emergency shutdown of the plant was enforced to repair the troubled part of the line. The repair cost as well as production loss during the unscheduled plant shutdown has cost the company a great amount of financial loss. In this studies, a failure analysis of the cracked elbow was performed using NDT, chemical analysis, microstructural analysis including optical microscopy as well as scanning electron microscopy with EPMA, mechanical testings such as tensile testing, hardness testing and Charphy impact test fractography. The results indicated that several problems such as a welding defect and presence of a detrimental phase which was found to be relate to improper postforming heat treatment process was identified and the failure was concluded to be due to a low temperature embrittlement of the defect-containing elbows.

  • PDF

Advancing Risk Assessment through the Application of Systems Toxicology

  • Sauer, John Michael;Kleensang, Andre;Peitsch, Manuel C.;Hayes, A. Wallace
    • Toxicological Research
    • /
    • v.32 no.1
    • /
    • pp.5-8
    • /
    • 2016
  • Risk assessment is the process of quantifying the probability of a harmful effect to individuals or populations from human activities. Mechanistic approaches to risk assessment have been generally referred to as systems toxicology. Systems toxicology makes use of advanced analytical and computational tools to integrate classical toxicology and quantitative analysis of large networks of molecular and functional changes occurring across multiple levels of biological organization. Three presentations including two case studies involving both in vitro and in vivo approaches described the current state of systems toxicology and the potential for its future application in chemical risk assessment.