인공위성용 총방전 시스템의 해석 (Analysis of the battery charging and discharging system for spacecrafts)

  • 김영태;김희진
    • 전자공학회논문지B
    • /
    • 제32B권6호
    • /
    • pp.932-942
    • /
    • 1995
  • A spacecraft power system can be divided into two types : DET system(Direct Energy Transfer system) and PPT system(Peak Power Tracking system). In a DET system employing the regulated bus voltage control method, the battery charger and discharger are widely used for the bus voltage regulation. The battery charger has two different modes of operation. One is the bus voltage regulation mode and the other is the charge current regulation mode. The battery discharger is employed to provide the power when the spacecraft is in the earth's shadow or the sun is eclipsed. The operating mode, charging or discharging, is selected by a power control circuit. In this paper, small-signal dynamic characteristics of battery charging and discharging system are analyzed to facilitate design of control loop for optimum performance. Control loop designs in various operating modes are discussed. Anaylses are verified through experiments.

  • PDF

커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로 (Low-cost crowbar system and protection scheme in capacitor bank module)

  • 임근희;조주현;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

고역률, 고효율 충.방전기 (Charging-Discharging System with High Power Factor, High Efficiency)

  • 김은수;조기연;변영복;구헌회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.371-375
    • /
    • 1995
  • This paper presents equipment for charging and discharging with high power factor and high efficiency. This equipment is consisted of $3{\phi}$ SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor charging-discharging System.

  • PDF

유전체를 활용한 초고속 에너지 충/방전 소자 기술 (Recent Progress in Dielectric-Based Ultrafast Charging/Discharging Devices)

  • 최현수;류정호;윤운하;황건태
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.322-332
    • /
    • 2022
  • Energy storage capacitors based on dielectric ceramics with superior polarization properties and dielectric constant can provide much higher output power density due to their very fast energy charging/discharging rates, which are particularly suitable for operating pulsed-power devices. For an outstanding energy storage performance of dielectric capacitor, a large recoverable energy density could be derived by introducing a slim polarization-electric field hysteresis loop into dielectric materials by various technical approaches. Many research teams have explored various dielectric capacitor technologies to demonstrate high output power density and ultrafast charging/discharging behavior. This article reviews the recent research progress in high-performance dielectric capacitors for pulsed-power electronic applications.

A Design and Control of Bi-directional Non-isolated DC-DC Converter with Coupled Inductors for Rapid Electric Vehicle Charging System

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungil;Kim, Daegyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.429-430
    • /
    • 2011
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology with coupled inductors. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. The pre-charging mode employs the staircase shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

Rapid Electric Vehicle Charging System with Enhanced V2G Performance

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungik;Kim, Simon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.201-202
    • /
    • 2012
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. Each mode is operated according to battery states: voltage, current and State of Charging (SOC). The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system. Experiment waveforms confirm the proposed functionality of the charging system.

  • PDF

저온 잠열 축열조내의 열유동 특성에 관한 연구 (A study on Characteristics of Heat Flow of Low Temperature Latent Thermal Storage System)

  • 이원섭;박정원
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.33-43
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual all-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. With the relation of the aspect ratio(H/D) in the storage tank, the stratification is formed better as inlet flow rate is smaller. If the inlet and the outlet port are settled at the upside and downside of the storage tank, higher storage rate could be obtainable. In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maitained thin and the degree of stratification increases respectively. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient in case of inlet temperature, the large temperature difference between inflowing water and storage water are influenced from the thermal conduction. The effect of the reference temperature difference is seen differently in comparison with the former study for chilled and hot water. In the discharging process, the thermal stratification is improved by the effect of the thermal stratification of the charging process.

  • PDF

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF

제연기 개스유동 해석에 관한 연구 (A Study of Bore Evacuator Gas Flow Analysis)

  • 강국정
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1083-1087
    • /
    • 1996
  • Bore evacuator which have circular structure of cylindrical form is located at tube, and its function is to evacuate toxic gases generated during firing intervals. Between bore evacuator and bore interior, gas flow field is developed through the nozzles, and the charging and discharging process is formed. By these flow cycle(charging and discharging) the evacuation effect can be generated. This report contains an analyses and results consideration about bore evacuator flowfield.

  • PDF

폴리염화비닐(PVC)의 코로나 대전현상에 관한 연구 (A study on the Corona Electrification Phenomena for Polyvinyl chloride (PVC))

  • 박구범;황명환;조기선;이덕출;임헌찬
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.57-62
    • /
    • 1992
  • In this thesis, the electrification phenomenon was studied by measurement of charging current and discharging current in polymers when the carriers generated by corona discharge were supplied to the surface of polymers. Corona charging current of PVC, polar and noncrystalline polymer, was larger than that of nonpolar and amorphous polymers. Corona charging current on the specimen of naked upper surface (CIM) was larger than charging current on the specimen of electrode made. Carrier injection differed from interfacial phase of polymer surFace. The transfer phenomenon vaned with chemical structure of polymer and then the polar effect of PVC was remarkable because of large electron affinity of Cl. In the characteristics of discharging current of PVC, the abnormal current was observed. It was supposed that this phenomena presented the trap of injected carriers in PVC and that static electricity phenomenon was generated by trap.