• Title/Summary/Keyword: charge order

Search Result 1,639, Processing Time 0.03 seconds

Influence of Filler Shape on Dielectric & Electric Charge-Discharge Properties of Filled Epoxy Resin (에폭시 수지의 유전특성.충방전특성에 미치는 충전제 형상의 영향)

  • 이성일;박일규;류성림;주인규
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.81-84
    • /
    • 2000
  • In this paper, we have the investigated the Influence of Filler Shape on Dielectric & Electric Charge-Discharge Properties of Filled Epoxy Resin. In the low frequency range from 50Hz to a few kHz, the magnitude of tan$\delta$ become larger in the order, NON, RAS, SAS, SCS. The electrical Discharge of RAS measured for 60 min, decreased after 10$^2$∼10$^3$.

  • PDF

Study on the Address Discharge Characteristics for the Improvement of the Mis-firing Problem in AC PDP (AC PDP의 오방전 개선을 위한 어드레스 방전 특성 연구)

  • Jeon, Won-Jae;Kim, Dong-Hun;Lee, Seok-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1151-1156
    • /
    • 2009
  • Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.

Design of Charge Pump Circuit with VCO (VCO를 이용한 차지펌프 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.1
    • /
    • pp.118-122
    • /
    • 2011
  • For programming such as writing or erasing of the flash memory, two different kinds of high voltage are required, and the charge pump circuit has been used for this. The charge pump circuit proposed in this paper uses the VCO to adjust the clock frequency in order to match the reference voltage approved from the outside and the charge pump's output. Accordingly, I suggest a circuit that can produce a predictable output, regardless of not only an error by fabrication but also MOSFET's body effect generated in each part of the charge pump.

The improved efficiency Study of PV system for the Solar lamp lighting (태양광 가로등 발전 효율개선 연구)

  • Kang, Sin-Young;Lee, Yang-Guy;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.304-308
    • /
    • 2002
  • This paper studies stand-alone photovoltaic array for solar lighting lamp. The solar lighting lamp has PV modules, batteries. and charge & discharge system. The charge efficiency is improved for the control of each battery which is divided the charge from the discharge to change the structure of existing solar lighting lamp charge & discharge system. so, the charge and discharge times are reduced of 50%. and the depth of discharge control can be controlled in the discharge cut off voltage. This can be effective of battery use. If a battery is out of order, this system can be executed for a regular period. so we saved the repair cost and developed of system's stabilization. It is possible economical effect to apply for solar lighting lamp used photovoltaic array.

  • PDF

A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer (변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구)

  • 권석두;남상천
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF

Computational Study on the Dependence of Electronic Transition Energies of Porphin, Chlorin, Mg-Chlorin and Chlorophyll a on an External Charge

  • Kwon, Jang Sook;Yang, Mino
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.453-459
    • /
    • 2013
  • In phtosynthetic light harvesting complexes, the electronic transition energies of chlorophylls are influenced by the Coulombic interaction with nearby molecules. Variation of the interactions caused by structural inhomogeneity in biological environment results in a distribution of disordered electronic transition energies of chlorophylls. In order to provide a practical guide to predict qualitative tendency of such distribution, we model four porphyrin derivatives including chlorophyll a molecule interacting with an external positive charge and calculate their transition energies using the time dependent density functional method. It is found that ${\pi}-{\pi}^*$ transition energies of the molecules are generally blue-shifted by the charge because this stabilizes occupied molecular orbitals to a greater extent than unoccupied ones. Furthermore, new transitions in the visible region emerge as a result of the red-shift in energy of an unoccupied Mg orbital and it is suggested that light-induced electron transfer may occur from the tetrapyrrole ring to the central magnesium when the molecules are interacting with a positive charge.

A Study of the Irradiation Environment Effects on the Electrical Properties of Ethylene Propylene Rubber (방사선 조사 환경에 의한 에칠렌 프로필렌 고무의 전기 특성에 관한 연구)

  • 이성일
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.2
    • /
    • pp.187-200
    • /
    • 2000
  • The charge and discharge current in EPR(Ethylene Propylene Rubber), which were irradiated with the radiant capacity of 0~600 [kgy/h], have been measured in order to investigate the influence of the atmosphere (oxygen, air and vacuum) on electrical properties. It has been shown that the charge and discharge current increase as the amount of radiant capacity increases in air and vacuum atmosphere. This electrical property degradation can be speculated due to that the C=O radicals or impurities, which comes from during shaping process, may act as dipoles. On the other hand, the charge and discharge current are shown to be higher in the amount of 1[kgy/h] than these in 10[kgy/h] in air atmosphere, because the charge and discharge current can be increased as the exposure time is extended with slower rate. Under the same amount of irradiation, the charge and discharge current in oxygen atmosphere are shown to be higher than those in vacuum. This is possibly due to that the main chain can be broken by oxidation when it is exposed to the $\gamma$ -rays.

  • PDF

A Study of the Characteristics of the High-flowable Concrete according to the change of charge-time of superplasticize (유동화제 첨가시기에 따른 콘크리트의 특성에 관한 실험적 연구)

  • Kwon, Chun-Ahn;Jeon, Hyun-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.115-122
    • /
    • 2003
  • In order to analyze liquidity change according to increasing the charge of superplasticizer, we inputted charges by dividing into six steps, 0% through 1.25%; at the same time, to observe liquidity change according to the change of charge-time, we carried out the experiment applying 30-minute intervals, i.e. at beginning of mixing, 30, 60 and 90 minutes. The results are below. 1) According to increasing the charge of superplasticizer, the liquidity of concrete was enhanced, however, when inputted 1.25%, a little segregation was occurred, which allowed us to make a conclusion that concrete performance would be deteriorated due to this segregation. 2) When we inputted 1.25% of superplsticizer, steady liquidity features were shown regardless of the charge-time of concrete, which allowed us to make a conclusion that this input would be the best for liquidity performance considering only liquidity features. 3) After analyzing the dynamical features of liquid concrete, the result showed that there was not significant effect on revelation of compressive strength. We concluded form this result that there was no influence on the stripping-time of a mold form. 4) When we charge superplasticizer in concrete more than 1%, we, in advance, should clearly judge the concrete performance required during constructing in site, as it were, the compressive strength or liquidity etc.; furthermore, we had better decide a charge and input-time of superplasticizer to meet the required performance.

Comparison of Flocculati on-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Sang-Kyu Kam;Lee
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.137-144
    • /
    • 1992
  • Flocculation-spectrophotometry and streaming current detector( SCD ) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the formal. and was determined with the dosage required during charge neutralization of humic acid for the latter It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humid acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density, Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Influence of Particle and Filter Charge on Filtration Property of Air Filter under Particle Loading (입자 및 필터 대전상태에 따른 입자부하조건에서 공기정화 필터의 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.644-655
    • /
    • 2012
  • As soon as a new air filter is applied to an air purification process, the filter gets loaded with dust particles. Thus, the study on the particle loading characteristics of air filter is very essential in order to understand the real filtration phenomena during filter use. In this study, we investigated the effect of particle and filter charge on the particle loading property of air filter. Charged filter and uncharged filter prepared by discharging the charged filter by isopropyl alcohol were used as test samples, and three types of particle having different charge states were supplied to filters tested. For neutralized particles there was a big difference in areal mass loading rates between charged and uncharged filters due to the very small amount of particle charge, on the other hand the difference was diminished for atomized particle and finally almost vanished for corona charged particles. The pressure drop of filter loaded with corona charged particles was only half of those for neutralized and atomized particles at the same areal mass loading because of the porous structure of particle deposit formed on filter fibers, caused by the space charge effect between particles.