• Title/Summary/Keyword: charge Injection

Search Result 365, Processing Time 0.029 seconds

Solution-Processed Quantum Dot Light-Emitting Diodes with TiO2 Nanoparticles as an Electron Transport Layer and a PMMA Insulating Layer (TiO2를 전자수송층으로 적용하고 PMMA 절연층을 삽입한 용액공정 기반 양자점 전계 발광 소자의 활용)

  • Kim, Bomi;Kim, Jungho;Kim, Jiwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.1
    • /
    • pp.93-97
    • /
    • 2022
  • We report highly efficient quantum dot light-emitting diodes (QLEDs) with TiO2 nanoparticles (NPs) as an alternative electron transport layer (ETL) and poly (methyl methacrylate) (PMMA) as an insulating layer. TiO2 NPs were applied as ETLs of inverted structured QLEDs and the effect of the addition of PMMA between ETL and emission layer (EML) on device characteristics was studied in detail. A thin PMMA layer supported to make the charge balance in the EML of QLEDs due to its insulating property, which limits electron injection effectively. Green QLEDs with a PMMA layer produced the maximum luminance of 112,488 cd/m2 and a current efficiency of 25.92 cd/A. We expect the extended application of TiO2 NPs as the electron transport layer in inverted structured QLEDs device in the near future.

Perception of the Nurse on the Nursing Malpractice and Its Case (간호사고와 관련판례에 대한 임상간호사의 지각)

  • Jeong, Ji-Yun;Lee, Myung-Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.3
    • /
    • pp.445-462
    • /
    • 1999
  • The purpose of this study is to provide some basic data for the direction of nursing education and practice to prevent nursing malpractice as investgating perception of the nurse on the nursing malpractice and its case. Data were collected from 450 nurse working in four general hospitals which were located in Chonbuk province from November 9 to 21, 1998 through questionnare. The structured instruments developed by the reseacher were used for collecting data. The Results were as follows: 1) As for the cognition of the nursing malpractice case, the transfusion accident was 37.3%, the side-effects of KCL injection(19.3%), hymen rupture by uterus cancer test, the side-effects of aminophyllin injections on dyspnea patient and the others were 10% below. 2) With regard to the channel of the perception of the nursing malpractice case, mass-communication was taken first and followed through by neighbors, In-service education, school education, continuing education 3) As for the direct${\cdot}$indirect experience of the nursing malpractice case, transfusion accident was 51.3%, the fall of NPO patient after an operation 40.1%, the side-effect of KCL injection 32.5%, suicide of the psychiatric patient 32.5%, and the others were 30% below. 4) The possibility of nursing malpractice case was an average 2.57(${\pm}$0.91) and the highest was the fall of the NPO patient after an operation. 5) The perception on the responsibility of the nursing malpractice in its case was indicated as a joint-fault in ten nursing malpractice instances. As compared to the real decision, nurse's perception of the responsibility in the fall of the NPO patient after an operation, the side-effect of KCL injection, the tracheal edema of the patient who had a thyroid operation, the suicide of psychiatric patient, the hymen rupture by uterus cancer test accorded real decisions. But the other cases were different from the real decisions. These cases were perceived as ones of joint fault even in cases determined as Dr's single fault cases or those in which both doctor and nurse were declared free of fault. 6) Knowledge levels of the nursing malpractice, school education and In-service education were perceived as low but anxiety levels of the malpractice were high. 7) With regard to the countmeasure of the hospital after nursing malpractice, the rate answered as "the practice settled the accident temporarily and forced the person in charge to be punished" was highest. In conclusion, the level of the cognition of the clinical nurse on nursing malpractice cases was low. As nurses' perception on the responsibility of the nursing malpractice case was compared to the real decision, there was a difference in five cases out of the ten cases.

  • PDF

Performance Characteristics of Organic Electroluminescence Diode Using a Carbon Nanotube-Doped Hole Injection Layer (탄소 나노튜브가 도입된 정공 주입층에 의한 유기발광다이오드의 성능 특성 연구)

  • Kang, Hak-Su;Park, Dae-Won;Choe, Youngson
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.418-423
    • /
    • 2009
  • MWCNT(multi-wall carbon nanotube)-doped PEDOT:PSS(poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate)), used as a HIL(hole injection layer) material in OLEDs(organic light emitting diodes), was spin-coated on to the ITO glass to form PEDOT:PSS-MWCNT nano composite thin film. Morphology and transparency characteristics of nano composite thin films with respect to the loading percent of MWCNT have been investigated using FT-IR, UV-Vis and SEM. Furthermore, ITO/PEDOT:PSS-MWCNT/NPD/$Alq_3$/Al devices were fabricated, and then J-V and L-V characteristics were investigated. Functional group-incorporated MWCNT was prepared by acid treatment and showed good dispersion property in PEDOT:PSS solution. PEDOT:PSS-MWCNT thin films possessed good transparency property. For multi-layered devices, it was shown that as the loading percent of MWCNT increased, the current density increased but the luminance dramatically decreased. It might be conclusively suggested that the enhanced charge mobility by MWCNT could increase the current density but the hole trapping property of MWCNT could dramatically decrease the hole mobility in the current devices.

Changes in Hospital and Clinic Care Patterns Under the Medical Insurance System (의료보험 실시후 2년간의 진료양상의 변화 -서울시내 의료기관 입원환자를 중심으로-)

  • Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.14 no.1
    • /
    • pp.3-12
    • /
    • 1981
  • To identify the changes in professional care patterns after the introduction of medical insurance in Korea, professional care in hospitals and clinics of two succeeding years were compared. The hospitals and clinics selected for this study were those which located in Seoul city. Hospitals were classified into 3 categories: university hospital, general hospital and hospital. The diseases selected for this study were acute appendicitis and normal delivery. They were selected because their disease courses are considered to be fairly stable. The variables used for this study were length of stay, total hospital costs, costs of each components of cares. The information used for this study was obtained from the official forms requested by the medical facilities to the Korea Medical Insurance Corporation. The two periods studied were 3 months of each year from March 1st to May 31st in 1979 and 1980, The total number of normal delivery studied was 289 in 1979, 301 in 1980 respectively and the acute appendicitis was 92 and 111 respectively. In order to compare the quantity of medical care between 2 study periods the insurance price scores of 1979 were converted to prices of 1980. For statistical test of difference between 2 periods T-test and Welch's test were used. The result of the study were briefly summarized in below. 1. No significant difference was observed in the average length of stay of both disease between two study periods in all types of hospitals. 2. No significant difference was observed in the average total hospital costs of both diseases in all types of hospital, but in the private clinic the average clinic costs was rather decreased significantly in 1980. 3. More cost decrease were seen than cost increase in 1980 in all types of facilities, More cost changes by items were seen in acute appendicitis than in normal delivery between two study periods. The total hospital costs can be devided into 2 portions: charges for drug and material and for physician. In normal delivery, costs for physician's charges was significantly decreased in almost all the hospitals and costs for drug and material were not changed significantly in all the hospitals in 1980. In the university hospitals, however, the costs for drug and material were increased significantly in 1980. The cost decrease for physician's charge were mainly due to the decrease in the costs of laboratory test, treatment and physical therapy. The increase in the costs for the drug and material in the university hospitals was mainly due to the increase in the cost for drugs for oral administration and injection. 4. The proportion of components of medical care in the hospital has not been changed significantly, however, the cost for injection in normal delivery was characteristically increased in 1980 in all hospitals studied. In general the proportion of the costs for drug and material was tended to increase and the costs for physician was tended to decrease in 1980. The increase in the costs for drug and material were considered to be due to increase in the cost for drugs for oral administration and injection. The decrease in the costs for physician were due to decrease in the costs of laboratory test, treatment and physical therapy. Above mentioned changes in hospital and clinic care patterns are considered to be mostly influenced by the review criteria set by the K.I.C. for the assessment of the fee request made by clinics and hospitals.

  • PDF

Evaluation of 99mTc-MAG3-2-nitroimidazole for hypoxic tumor imaging

  • Lee, Yun-Sang;Kim, Young Joo;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.18-25
    • /
    • 2019
  • 2-Nitroimidazole derivatives have been reported to accumulate in hypoxic tissue. We prepared a novel $^{99m}Tc-MAG_3$-2-nitroimidazole and evaluated the feasibility for hypoxia imaging agent. $Bz-MAG_3$-2-nitroimidazole was synthesized by direct coupling of $Bz-MAG_3$ and 2-nitroimidazole using dicyclohexylcarbodiimide. $Bz-MAG_3$-2-nitroimidazole was labeled with $^{99m}Tc$ in the presence of tartaric acid and $SnCl_2-2H_2O$ at $100^{\circ}C$ for 30 min. And the reaction mixture was purified by $C_{18}$ Sep-pak cartridge. The labeling efficiency and the radiochemical purity were checked by ITLC-SG/acetonitrile. The tumor was grown in balb/c mice for 8~13 days after the subcutaneous injection of tumor cells, CT-26 (murine colon adenocarcinoma cell). Biodistribution study and tumor autoradiography were performed in the xenografted mice after i.v injection of 74 kBq/0.1 mL and 19 MBq/0.1 mL of $^{99m}Tc-MAG_3$-2-nitroimidazole, respectively. In vivo images of $^{99m}Tc-MAG_3$-2-nitroimidazole in tumor bearing mice were obtained 1.5 hr post injection. The labeling efficiency was $45{\pm}20%$ and the radiochemical purity after purification was over 95%. Paper electrophoresis confirmed negative charge of $^{99m}Tc-MAG_3$-2-nitroimidazole. $^{99m}Tc-MAG_3$-2-nitroimidazole was very stable at room temperature and its protein binding was 53%. The $^{99m}Tc-MAG_3$-2-nitroimidazole exhibited high uptake in the liver, stomach and intestine. In biodistribution study using tumor bearing mice, the uptakes (% ID/g) of the tumor were $0.5{\pm}0.1$, $0.4{\pm}0.0$, $0.2{\pm}0.1$ and $0.1{\pm}0.1$ at 5, 15, 30 min and 4 hrs. Tumor/muscle ratio were $1.4{\pm}0.1$, $2.2{\pm}0.83$, $3.0{\pm}0.9$, and 3.7 (n=2) for 5, 15, 30 min and 4 hrs. The uptake in hypoxic area was found higher than in non-hypoxic area of tumor tissue by autoradiography. In vivo images showed the relatively faint uptake to the hypoxic tumor region. $^{99m}Tc-MAG_3$-2-nitroimidazole was successfully synthesized and found feasible for imaging hypoxia.

Effect of Intake Pressure on Emissions and Performance in Low Temperature Combustion Operation of a Diesel Engine (디젤 저온연소 운전 영역에서 흡기압이 엔진 성능에 주는 영향)

  • Lee, Sun-Youp;Chang, Jae-Hoon;Lee, Yong-Gyu;Oh, Seung-Mook;Kim, Yong-Rae;Kim, Duk-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.88-94
    • /
    • 2012
  • One of the effective ways to reduce both $NO_x$ and PM at the same time in a diesel CI engine is to operate the engine in low temperature combustion (LTC) regimes. In general, two strategies are used to realize the LTC operation-dilution controlled LTC and late injection LTC - and in this study, the former approach was used. In the dilution controlled regime, LTC is achieved by supplying a large amount of EGR to the cylinder. The significant EGR gas increases the heat capacity of in-cylinder charge mixture while decreasing oxygen concentration of the charge, activating low temperature oxidation reaction and lowering PM and $NO_x$ emissions. However, use of high EGR levels also deteriorates combustion efficiency and engine power output. Therefore, it is widely considered to use increased intake pressure as a way to resolve this issue. In this study, the effects of intake pressure variations on performance and emission characteristics of a single cylinder diesel engine operated in LTC regimes were examined. LTC operation was achieved in less than 8% $O_2$ concentration and thus a simultaneous reduction of both PM and $NO_x$ emission was confirmed. As intake pressure increased, combustion efficiency was improved so that THC and CO emissions were decreased. A shift of the peak Soot location was also observed to lower $O_2$ concentration while $NO_x$ levels were kept nearly zero. In addition, an elevation of intake pressure enhanced engine power output as well as indicated thermal efficiency in LTC regimes. All these results suggested that LTC operation range can be extended and emissions can be further reduced by adjusting intake pressure.

Electrochemical Behavior of Light Lanthanide Ions in Nonaqueous Solution, Flow Injection Determination and Photochemical Characterization of Eight Coordinated Chelates of Heavy Metal Ions (Part I) Electrochemical Behavior of Light Lanthanide Ions in Nonaqueous Solution (물아닌용매에서 가벼운 란탄족 이온의 전기화학적 거동, 흐름주입에 의한 정량 및 중금속이온의 킬레이트형 8-배위 착물의 광화학적 특성 (제 1 보) 물아닌용매에서 가벼운 란탄족이온의 전기화학적 거동)

  • Kang, Sam-Woo;Pak, Chong-Min;Do, Lee-Mi;Song, Myoung-Kyu;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.361-369
    • /
    • 1994
  • Voltammetric behavior of some light lanthanide ions($La^{3+}$, $Pr^{3+}$, $Nd^{3+}$, $Sm^{3+}$ and $Eu^{3+}$) in acetonitrile(AN) and dimethylformamide(DMF) has been investigated by direct current, differential pulse polarography and cyclic voltammetry. The reduction of $La^{3+}$, $Pr^{3+}$ and $Nd^{3+}$ in 0.1M TEAP proceeded directly to the metallic state through three-electron charge transfer of irreversible process where as $Sm^{3+}$ and $Eu^{3+}$ proceeded by charge transfer of two steps. As the results of the cyclic voltammetric investigation, the first step reduction of $Sm^{3+}$ and $Eu^{3+}$ were a quasireversible reaction, the second step reductions were an irreversible reaction. The cathodic peak currents of the differential pulse polarogram showed adsorptive properties at lower sweep rates and high concentrations of these metal ions. The peak potenital was shifted to a negative petential and the peak current decreased with the increase of percentage of water in AN. On the other hand, the peak potential was shifted to a positive potential and the peak current decreased with an increased percentage of water in DMF.

  • PDF

Analysis of Factors which Affect the Medical Utilization Fee after an Increase of Health Insurance Benefits for Patients with Serious Illnesses (건강보험 중증질환 급여확대 전후에 따른 진료비 차이에 관한연구)

  • Lee, Jung-He;Lee, Moo-Sik;Kim, Jee-Hee;Moon, Tae-Young;Kim, Yong-Ha;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1504-1510
    • /
    • 2010
  • According to a research analysis of the factors which affect the medical utilization fee after an increase of health insurance benefits for patients with serious illnesses based on 225 patients over 6 months, both before and after the increase of benefits, from January, 1st, 2005 to June 30th, and also from January, 1st, 2006 to June 30th. In terms of genders, 67.8% of males were affected, whereas only 32.2% of females were effected, a much higher rate of men than women. Men also had higher rates before and after the increase of benefits. Out of 5 categories related to medication and treatment, radiation testing was the most expensive at about 5,300,000, operation fees were 590,000, and costs of other testing approximately 200,000 with the least expensive category being 120,000 for medication. By looking at the relationship between the fees and increase of benefits, medication was a hospital charge (p<0.01), injection fees were hospital charges (p<0.01), operation fees were hospital charges (p<0.01). Medication fees (p<0.01) and injection fees (p<0.01) were found to be related.

Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome (심폐바이패스 없이 시행하는 관상동맥 우회수술 중의 혈역학적 변수들의 변화양상 및 수술 후 결과에 미치는 영향)

  • 허재학;장지민;김욱성;장우익;이윤석;정철현
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.576-582
    • /
    • 2003
  • During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. Material and Method: From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71 The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin 1 and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay. Result: The number of mean distal anastomoses was 2.8$\pm$0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2$\pm$46.7 for CK-MB, 0.69$\pm$0.86 for troponin 1 on postoperative day f. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed. Conclusion: The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic charge of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.

Decreases in $Casz1$ mRNA by an siRNA Complex Do not Alter Blood Pressure in Mice

  • Ji, Su-Min;Shin, Young-Bin;Park, So-Yon;Lee, Hyeon-Ju;Oh, Berm-Seok
    • Genomics & Informatics
    • /
    • v.10 no.1
    • /
    • pp.40-43
    • /
    • 2012
  • Recent genomewide association studies of large samples have identified genes that are associated with blood pressure. The Global Blood Pressure Genetics (Global BPgen) and Cohorts for Heart and Aging Research in Genome Epidemiology (CHARGE) consortiums identified 14 loci that govern blood pressure on a genomewide significance level, one of which is $CASZ1$ confirmed in both Europeans and Asians. $CASZ1$ is a zinc finger transcription factor that controls apoptosis and cell fate and suppresses neuroblastoma tumor growth by reprogramming gene expression, like a tumor suppressor. To validate the function of $CASZ1$ in blood pressure, we decreased $Casz1$ mRNA levels in mice by siRNA. $Casz1$ siRNA reduced mRNA levels by 59% in a mouse cell line. A polyethylenimine-mixed siRNA complex was injected into mouse tail veins, reducing $Casz1$ mRNA expression to 45% in the kidney. However, blood pressure in the treated mice was unaffected, despite a 55% reduction in $Casz1$ mRNA levels in the kidney on multiple siRNA injections daily. Even though $Casz1$ siRNA-treated mice did not experience any significant change in blood pressure, our study demonstrates the value of $in$ $vivo$ siRNA injection in analyzing the function of candidate genes identified by genomewide association studies.