• 제목/요약/키워드: characteristic mode

검색결과 1,082건 처리시간 0.03초

Lossless Compression for Hyperspectral Images based on Adaptive Band Selection and Adaptive Predictor Selection

  • Zhu, Fuquan;Wang, Huajun;Yang, Liping;Li, Changguo;Wang, Sen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권8호
    • /
    • pp.3295-3311
    • /
    • 2020
  • With the wide application of hyperspectral images, it becomes more and more important to compress hyperspectral images. Conventional recursive least squares (CRLS) algorithm has great potentiality in lossless compression for hyperspectral images. The prediction accuracy of CRLS is closely related to the correlations between the reference bands and the current band, and the similarity between pixels in prediction context. According to this characteristic, we present an improved CRLS with adaptive band selection and adaptive predictor selection (CRLS-ABS-APS). Firstly, a spectral vector correlation coefficient-based k-means clustering algorithm is employed to generate clustering map. Afterwards, an adaptive band selection strategy based on inter-spectral correlation coefficient is adopted to select the reference bands for each band. Then, an adaptive predictor selection strategy based on clustering map is adopted to select the optimal CRLS predictor for each pixel. In addition, a double snake scan mode is used to further improve the similarity of prediction context, and a recursive average estimation method is used to accelerate the local average calculation. Finally, the prediction residuals are entropy encoded by arithmetic encoder. Experiments on the Airborne Visible Infrared Imaging Spectrometer (AVIRIS) 2006 data set show that the CRLS-ABS-APS achieves average bit rates of 3.28 bpp, 5.55 bpp and 2.39 bpp on the three subsets, respectively. The results indicate that the CRLS-ABS-APS effectively improves the compression effect with lower computation complexity, and outperforms to the current state-of-the-art methods.

A SEARCH FOR AGN INTRA-DAY VARIABILITY WITH KVN

  • LEE, TAESEOK;TRIPPE, SASCHA;OH, JUNGHWAN;BYUN, DO-YOUNG;SOHN, BONG-WON;LEE, SANG-SUNG
    • 천문학회지
    • /
    • 제48권5호
    • /
    • pp.313-323
    • /
    • 2015
  • Active galactic nuclei (AGN) are known for irregular variability on all time scales, down to intra-day variability with relative variations of a few percent within minutes to hours. On such short timescales, unexplored territory, such as the possible existence of a shortest characteristic time scale of activity and the shape of the high frequency end of AGN power spectra, still exists. We present the results of AGN single-dish fast photometry performed with the Korean VLBI Network (KVN). Observations were done in a “anti-correlated” mode using two antennas, with always at least one antenna pointing at the target. This results in an effective time resolution of less than three minutes. We used all four KVN frequencies, 22, 43, 86, and 129 GHz, in order to trace spectral variability, if any. We were able to derive high-quality light curves for 3C 111, 3C 454.3, and BL Lacertae at 22 and 43 GHz, and for 3C 279 at 86 GHz, between May 2012 and April 2013. We performed a detailed statistical analysis in order to assess the levels of variability and the corresponding upper limits. We found upper limits on flux variability ranging from ~1.6% to ~7.6%. The upper limits on the derived brightness temperatures exceed the inverse Compton limit by three to six orders of magnitude. From our results, plus comparison with data obtained by the University of Michigan Radio Astronomy Observatory, we conclude that we have not detected source-intrinsic variability which would have to occur at sub-per cent levels.

$\lambda$/4 Hairpin 공진기를 이용한 2.4 GHz 대역 LTCC 대역통과 필터의 설계 (The Design of 2.4 GHz Band LTCC Bandpass Filter using $\lambda$/4 Hairpin Resonators)

  • 성규제
    • 마이크로전자및패키징학회지
    • /
    • 제11권4호
    • /
    • pp.7-11
    • /
    • 2004
  • 본 논문에서는 $\lambda$/4 헤어핀 공진기를 2.4 GHz 대역의 LTCC(Low Temperature Co-fire Ceramic) 대역통과 필터의 설계에 적용하였다. $\lambda$/4 헤어핀 공진기는 전송선로의 폭을 일정하게 유지한 상태로 특성임피던스를 변화시킬 수 있어, 등가적으로 SIR(Stepped Impedance Resonator)로 동작한다. $\lambda$/4 헤어핀 공진기는 평행결합 선로와 전송선로 부분으로 구성된다. 따라서 공진기의 두 부분의 특성임피던스는 서로 다른 값을 갖는다. 또한 공진기 사이의 결합량을 조절하기 위하여 사용하는 부가적인 결합 패턴은 결합위치에 따라 결합량을 다르게 할 수 있다. 평행 결합선로의 결합 구조와 부가적인 결합 패턴을 모두 고려한 대역통과 필터를 설계하기 위해서 두 결합구조의 등가회로를 하나의 인버터로 통합하는 과정을 제시하였다. 2.4GHz 대역에서 150 MHz 대역폭의 대역통과 필터를 적층 구조로 설계하여 설계 결과와 잘 일치하는 특성을 얻었다.

  • PDF

RF Magnetron Sputtering으로 증착된 ZnO의 증착 특성과 이를 이용한 Thin Film Transistor특성 (Thin Film Transistor Characteristics with ZnO Channel Grown by RF Magnetron Sputtering)

  • 김영웅;최덕균
    • 마이크로전자및패키징학회지
    • /
    • 제14권3호
    • /
    • pp.15-20
    • /
    • 2007
  • 플라스틱 기판에 적용이 가능한 최대 공정온도 $270^{\circ}C$ 이하에서 ZnO-TFT 소자를 제작하였다. ZnO-TFT 소자는 bottom gate 구조로 제작되었으며, ICP-CVD로 형성된 $SiO_2$ 산화물 게이트 공정을 제외하고는 모든 박막증착 공정은 RF-magnetron sputtering process를 이용하였다. ZnO 박막은 Ar과 $O_2$ gas 유량의 비율에 따라 여러 가지 조건에서 RF-magnetron sputtering 시스템을 이용하여 상온에서 증착하였다. Ar과 $O_2$ gas의 비율에 따라 제작된 TFT 소자는 모두 enhancement 모드의 소자특성을 나타내었고, 또한 가시광선영역에 있어 80% 이상의 높은 투과율을 보였다. ZnO 증착시 순수 Ar을 사용하여 제작된 ZnO-TFT의 경우에, $1.2\;cm^2/Vs$의 field effect mobility, 8.5 V의 threshold voltage, 그리고 $5{\times}10^5$의 높은 on/off ratio, 1.86 V/decade의 swing voltage로 가장 우수한 전기적 특성을 보였다.

  • PDF

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

2.5MW 풍력발전기 동력분기식 기어트레인의 진동특성 (Vibration characteristics of power differential gear train for 2.5MW wind turbine)

  • 김정수;박노길;이형우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.253-261
    • /
    • 2014
  • 본 연구에서는 스퍼 유성기어시스템 2단, 헬리컬기어 시스템 1단으로 구성되어 있고, 메인 축과 증속기가 플랜지 결합되어 있는 동력분기식 2.5MW 풍력발전기에 대해 진동해석을 수행하였다. 유성기어시스템, 헬리컬기어시스템, 메인 축 등은 MASTA 상용프로그램으로 모델링하고, 기어박스 케이스, 토크암, 유성캐리어, 플랜지 등은 유한요소법으로 모델링하였으며, 부분구조합성법으로 조합하여 진동해석을 수행하였다. 2.5MW 동력분기식 풍력발전기 기어트레인의 고유진동 특성 해석을 수행하였고, 블레이드 풍하중에 의한 가진, 질량불평형, 축 어긋남 등에 발생하는 가진원에 대해 위험속도 분석을 하였다.

Experimental study on the seismic performance of concrete filled steel tubular laced columns

  • Huang, Zhi;Jiang, Li-Zhong;Chen, Y. Frank;Luo, Yao;Zhou, Wang-Bao
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.719-731
    • /
    • 2018
  • Concrete filled steel tubular (CFST) laced columns have been widely used in high rise buildings in China. Compared to solid-web columns, this type of columns has a larger cross-section with less weight. In this paper, four concrete filled steel tubular laced columns consisting of 4 main steel-concrete tubes were tested under cyclic loading. Hysteresis and failure mechanisms were studied based on the results from the lateral cyclic loading tests. The influence of each design parameter on restoring forces was investigated, including axial compression ratio, slenderness ratio, and the size of lacing tubes. The test results show that all specimens fail in compression-bending-shear and/or compression-bending mode. Overall, the hysteresis curves appear in a full bow shape, indicating that the laced columns have a good seismic performance. The bearing capacity of the columns decreases with the increasing slenderness ratio, while increases with an increasing axial compression ratio. For the columns with a smaller axial compression ratio (< 0.3), their ductility is increased. Furthermore, with the increasing slenderness ratio, the yield displacement increases, the bending failure characteristic is more obvious, and the hysteretic loops become stouter. The results obtained from the numerical analyses were compared with the experimental results. It was found that the numerical analysis results agree well with the experimental results.

다부하를 갖는 유도가열기기를 위한 고역률 이중 하프브릿지 직렬공진 인버터 (High Power Factor Dual Half Bridge Series Resonant Inverter for an Induction Heating Appliance with Multiple Loads)

  • 정용채
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.307-314
    • /
    • 1998
  • 근접부하의 동작주파수의 차이에 의해 발생하는 간섭가청잡음을 제거하기 위해서 다부하를 갖는 유도가열기를 위한 새로운 고역률 이중 하프브릿지 직렬공진 인버터를 제안한다. 이 회로는 하나의 인버터로 두 개의 유도가열요소를 독립적으로 전대역 출력제어를 할 수 있고 영전압 스위칭 특성 때문에 최소 스위칭 손실을 갖는다. 모드분석을 통해서 제안된 회로의 동작을 설명할 것이다. 요구되는 냉각능력을 평가하기 위해서 몇 개의 손실식을 유도함으로써 손실분석을 행하였다. 역률제어기능을 갖고 시스템의 크기를 축소하기 위해서 적절한 설계가이드를 제시하였다. 이렇게 설계된 값들을 사용하여 각 유도가열요소가 2.8kW 전력소모를 갖는 proto-type 회로를 구성하고 제안된 회로의 동작을 확인하기 위해서 실험을 행하였다.

  • PDF

수중 잠제구조물의 파랑 전달율과 안정성 및 기능성 평가 (Estimation on the Wave Transmission and Stability/Function Characteristics of the Submerged Rubble-Mound Breakwater)

  • 김용우;윤한삼;류청로;손병규
    • 한국수산과학회지
    • /
    • 제36권5호
    • /
    • pp.528-534
    • /
    • 2003
  • The 2-D hydraulic experimental results for the submerged rubble-mound structure, we have been concerned with the slability/function characteristics of the structures by the effects of wave force, scour/deposition at the toe and the wave transmission ratio at the lee-side sea. So, to investigate the variation characteristics of the wave transmission ratio which depended on a geometrical structure of the submerged breakwater profiles, the critical conditions for the depth of submergence and crest width were obviously presented. In summary, the results lead us to the conclusion that the wave control capabilities of submerged breakwaters by the variation of the submergence depth is higher than about 4 times the degree at the efficiency than the that of crest width. The destruction of the covering block at the crest generated at the region which was located between the maximum and minimum damage curve, and it's maximum damage/failure station from the toe of the structure was $0.2\;L_s.$ As the wave transmission coefficient and the slope of the structure increase, the damage/failure ratio and the maximum scour depth at the toe was extended, respectively. When the maximum scour depth happened, the destruction of the covering block which was located at the toe generated at the front of the submerged rubble-mound breakwater. Finally, it was found from the results that the optimization of the structure may be obtained by the efficient decision of the submergence depth and crest width in the permissible range of the wave transmission ratio.

APR 1400급 원자로냉각재펌프의 내진해석 (Seismic Analysis of APR1400 Grade Reactor Coolant Pump)

  • 안창기;유제용;박진석;함지웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.325-330
    • /
    • 2011
  • RCP(Reactor coolant pump) must be designed to preserve it's functions on normal or abnormal environments and seismic event same as operating basis earthquake(OBE) and safe shutdown earthquake(SSE). Generally, there are static and dynamic analytical method which can be applied by a floor response spectrum or time history analysis for the seismic qualification. Initially, It was accomplished a detailed structural FE-model for finite element analysis on the bases of 3-dimensional solid model which was made by the RCP drawing. As the result of dynamic characteristic using the detailed FE-model, it's shown about 12Hz natural frequency of 1st bending mode shape and maximum displacement has 11mm with the structural bending by single-point response spectrum(SPRS) method at all elevation. But maximum displacement has 7.6mm by multi-point response spectrum(MPRS) method which was applied to the three floor response spectrum at each elevation. Therefore, On a large heighten structures as RCP, The application by SPRS method causes to be more conservative results. Finally, A simpled equivalent beam model which was developed by use of iteration of detailed FE-model is shown the result more similar with those of natural frequencies and SPRS analysis. And maximum equivalent stress and displacement of the simpled beam has verified with 180MPa and 7.1mm each at 15sec as results by SSE time history method.

  • PDF