• 제목/요약/키워드: channel resonance

검색결과 148건 처리시간 0.022초

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.85-89
    • /
    • 2002
  • 목적 : 사람에 비하여 크기가 현저히 작은 동물의 자기공명영상 촬영을 위하여 상용으로 인체에 적용하는 Head 코일보다 원통 반지름이 작은 Low-Pass Type Birdcage 코일을 제작함으로써 보다 큰 신호대잡음비 (Signal-to-Noise Ratio. SNR)를 얻고자 하였다. 방법 : 자기공명영상을 얻기 위해 Spin Echo 펄스시퀀스와 Fast Spin Echo 펄스시퀀스를 사용하였다. T1 강조영상을 얻기 위한 Spin Echo 펄스시퀀스의 매개변수는 TR/TE=300/17 ㎳, Matrix=256$\times$256, Field Of View (FOV)=150 mm, Slice Thickness=2 mm 이었다. T2 강조영상을 얻기 위한 Fast Spin Echo 펄스시퀀스의 매개변수는 TR/TE=3000/96 ㎳, Matrix=256$\times$256, Field Of View (FOV)=150 mm, Slice Thickness=2 mm 이었다. 원통의 지름이 13 cm인 Birdcage 코일은 12개의 elements로 구성되어 있으며 길이는 22 cm로 제작되었다. 결과 : 코일 원통의 반지름의 크기에 따른 SNR을 비교하기 위하여 인체용 Knee 코일과 동물용으로 제작된 코일을 이용하여 각각의 팬톰 영상을 획득하였다. 팬톰 영상으로부터 측정된 SNR의 값을 통해 반지름이 작은 동물용 코일의 SNR이 더 크다는 걸 확인할 수 있었다. 토의 및 결론 : 본 연구를 통하여 같은 형태의 Birdcage 코일일 경우 원통의 반지름에 따라 SNR이 다르며, 특히 반지름이 작을 때 SNR이 더 크다는 것을 알 수 있었다. 따라서 코일의 크기에 비해 촬영하고자 하는 대상물의 부피가 작은 경우 대상물의 부피에 맞추어 코일을 제작하면 SNR이 보다 뛰어난 영상을 얻을 수 있을 것으로 사료된다.

  • PDF

JPEG 표준안을 이용한 의료 영상 압축 (Medical Image Compression Using JPEG International Standard)

  • 안창범;한상우;김일연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.504-506
    • /
    • 1993
  • JPEG(Joint Photographic Experts Group) 표준안은 디지털 정지 압축을 위하여 국제표준화기구(ISO/SC29/WG10)와 국제전신전화 자문회의(CCITT SG VIII)에 의해서 제안되었다. JPEG 표준안은 전자영상, 컴퓨터 그래픽, 멀티미디어 등과 관련하여 널리 응용되고 있으나, 의료 영상분야에서는 JPEG 압축의 손실 특성 때문에 사용이 매우 제한적이었다. 본 논문에서는 JPEG 표준안을 핵자기 공명 단층 영상 (256 gray levels, $256{\times}256$ size) 압축에 적용하여 그 성능을 조사하였다. 이를 위하여 JPEG 표준안 중 DCT에 기반을 둔 순차식 부호화 압축을 C-Cube Microsystems의 CL550 chip을 사용하여 구현하였고, 점진식 및 무손실 부호화 방식은 특별한 Hardware 없이 Software로 구현하여 실험하였다. 본 실험을 통하여 핵자기 공명 단층 시험 영상에 대해 거의 왜곡없이 약 10-20 정도의 압축률이 얻어짐을 확인할 수 있었다. 특히 JPEG으로 압축하였을 경우 재구성한 영상과 원영상과의 에러 신호가 random noise에 가깝게 나타남으로써 특별한 artifact가 없는 것도 JPEG의 큰 장점으로 부각된다. 한편 JPEG의 점진식 및 게층식 부호화 방식은 압축률과 신호대 잡음비에 있어서는 순차식과 동일하나, 거대한 영상 데이터 베이스 내에서의 빠른 탐색과 비교적 속도가 느린 공중망을 통한 원격 진단에 유용한 특성을 갖는다.

  • PDF

항암화학요법에 이은 확대 담낭절제술로 치료한 절제 불가능한 담낭암 (A Case of Unresectable Gallbladder Cancer Treated with Chemotherapy Followed by Extended Cholecystectomy)

  • 정광현;박진명;이재민;이상협;류지곤;김용태
    • Journal of Digestive Cancer Research
    • /
    • 제1권2호
    • /
    • pp.104-107
    • /
    • 2013
  • 담낭암은 진행된 상태에서 발견되었을 경우 예후가 매우 불량한 암으로 전신항암화학요법으로 치료를 하게 되나 일반적으로 고식적인 역할에 그치는 경우가 대부분이다. 본 증례는 원위부 림프절 전이가 있어서 수술적 절제가 불가능한 담낭암 환자에서 gemcitabine과 cisplatin을 병합한 전신항암화학요법으로 여섯 주기 치료 후 부분 관해를 얻어서 확대 담낭절제술이 가능하였던 증례로 매우 드문 증례를 경험하였기에 보고하는 바이다. 담낭암에서 수술 전 항암화학요법의 효과는 아직까지 확립되어 있지 않으나, 최근 양호한 종양 반응률과 종양 억제율을 보이는 항암화학요법이 개발됨에 따라서 그 가능성이 기대되고 있다.

  • PDF

Association between High Diffusion-Weighted Imaging-Derived Functional Tumor Burden of Peritoneal Carcinomatosis and Overall Survival in Patients with Advanced Ovarian Carcinoma

  • He An;Jose AU Perucho;Keith WH Chiu;Edward S Hui;Mandy MY Chu;Siew Fei Ngu;Hextan YS Ngan;Elaine YP Lee
    • Korean Journal of Radiology
    • /
    • 제23권5호
    • /
    • pp.539-547
    • /
    • 2022
  • Objective: To investigate the association between functional tumor burden of peritoneal carcinomatosis (PC) derived from diffusion-weighted imaging (DWI) and overall survival in patients with advanced ovarian carcinoma (OC). Materials and Methods: This prospective study was approved by the local research ethics committee, and informed consent was obtained. Fifty patients (mean age ± standard deviation, 57 ± 12 years) with stage III-IV OC scheduled for primary or interval debulking surgery (IDS) were recruited between June 2016 and December 2021. DWI (b values: 0, 400, and 800 s/mm2) was acquired with a 16-channel phased-array torso coil. The functional PC burden on DWI was derived based on K-means clustering to discard fat, air, and normal tissue. A score similar to the surgical peritoneal cancer index was assigned to each abdominopelvic region, with additional scores assigned to the involvement of critical sites, denoted as the functional peritoneal cancer index (fPCI). The apparent diffusion coefficient (ADC) of the largest lesion was calculated. Patients were dichotomized by immediate surgical outcome into high- and low-risk groups (with and without residual disease, respectively) with subsequent survival analysis using the Kaplan-Meier curve and log-rank test. Multivariable Cox proportional hazards regression was used to evaluate the association between DWI-derived results and overall survival. Results: Fifteen (30.0%) patients underwent primary debulking surgery, and 35 (70.0%) patients received neoadjuvant chemotherapy followed by IDS. Complete tumor debulking was achieved in 32 patients. Patients with residual disease after debulking surgery had reduced overall survival (p = 0.043). The fPCI/ADC was negatively associated with overall survival when accounted for clinicopathological information with a hazard ratio of 1.254 for high fPCI/ADC (95% confidence interval, 1.007-1.560; p = 0.043). Conclusion: A high DWI-derived functional tumor burden was associated with decreased overall survival in patients with advanced OC.

삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가 (Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors)

  • 박명환;이진완;이강원;류창우;장건호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.161-170
    • /
    • 2009
  • 목적 : 평행영상(Parallel imaging)기법의 개발로 긴 촬영시간 때문에 종종 사용되지 못하던 삼차원 영상기법이 최근 들어 환자 병을 진단하는데 새로이 사용되고 있다. 이 연구의 목적은 최근에 뇌 영상에서 개발되어 이용되고 있는 삼차원 자기공명영상을 사람의 뇌에서 짧은 시간 내에 얻을 수 있도록 2차원 평행영상 기법을 사용한 최적화 방법을 연구하는데 있다. 대상 및 방법 : 검사 장비는 3.0T 자기공명영상장치를 이용하였으며 8-채널 SENSE(sensitivity encoding) 머리 코일을 이용하였다. 팬텀 및 3명의 사람 머리에서 영상을 얻었다. 세 가지의 삼차원 영상법인 3D T1WI, 3D T2WI 및 3D FLAIR 영상 방법에 대하여 평행인자(SENSE factor)의 변화에 따른 팬텀 영상을 얻었다. 각각의 영상법에서 영상획득에 적당한 SENSE 인자를 찾기 위해 Phase encoding 방향과 Slice encoding 방향을 조합한 SENSE 인자를 변화시키면서 영상을 얻었다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 신호대 잡음비 (Signal-to-noise ratio, SNR), 감소분율(Percent Signal Reduction Rate, %R), 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과 : 팬텀을 이용한 SENSE 인자 변화에 따른 SNR 및 %R 값의 변화 결과 3D T1WI 방법에서 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우 약 0.2%의 신호 감소가 나타났고 영상시간은 5분 이내였다. 3D T2WI 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우에 약 1.0% 신호 감소가 나타났고 영상 시간은 약 5분 이내였다. 3D FLAIR 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 4를 사용한 경우에 약 0.2% 신호 감소가 나타났고 영상시간은 약 6분이었다. 사람을 대상으로 할 경우 3D T1W 및 3D T2W영상에서 SNR 및 CNR은 SENSE 인자를 3으로 한 경우에서 SENSE 인자를 4로 한 경우 보다 높게 나타났다. 3D FALIR 영상의 경우 CNR은 SENSE 4에서는 SENSE 3에 비하여 낮았다. 결론 : 본 연구에서는 3가지 3차원 영상법을 실제 임상적용이 가능한 시간 영역에서 SENSE 인자를 변화 시키면서 치적의 영상을 얻도록 하는 연구를 실시한 결과 SNR 감소를 최소화 하면서 영상획득 시간을 약 5분에서 6분 정도 소요되는 2차원 SENSE 인자를 찾았다. 이를 뇌 영상에 적용하였을 경우 SENSE 인자를 적용하지 않은 경우와 비교하면 신호 감소는 최소화 하면서 영상의 질은 큰 영향을 주지 않은 것으로 나타났다. 3D T1W및 3D T2W는 SENSE 인자를 3으로 3D FLAIR인자는 SENSE 인자를 4로 하는 것이 환자를 대상으로 한 뇌 영상에 적합하다고 생각된다. 앞으로는 이들 영상법이 뇌 영상뿐만 아니라 다른 영역의 영상에 적용을 위한 최적화가 필요하다고 생각된다.

  • PDF

3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램 (A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling)

  • ;;;조민형;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.107-119
    • /
    • 2014
  • 목적: 실제 촬영 결과와 전자기 모의실험 결과를 시각적으로 비교함으로써 위상배열코일을 이루는 모든 코일 요소의 감도를 효과적으로 검증할 수 있는 소프트웨어를 개발하였다. 대상과 방법: 위상배열코일검증기(PACE)라 불리는 프로그램을 MATLAB과 C언어를 이용해 구현하였다. 위상배열 코일검증기는 코일 소자의 3차원 형상 모델 구축, FDTD 모의실험 결과의 수용, 보통의 직각좌표계 및 코일면에 기준하는 직각좌표계 상에서 각기 코일 소자 감도를 도시하는 기능을 가지고 있다. 위상배열코일의 3차원 형상 모델을 구축하기 위해 바늘침 모양의 3차원 전자기 위치추적기를 사용하였다. 3차원 형상 모델을 만든 뒤, 이 형상 모델 데이터를 FDTD 모의실험 장치에 보낼 수 있게 하였다. 결과: 3차원 전자기 위치추적기를 이용해 실제 실험에 사용된 위상배열코일과 FDTD 모의실험에 사용된 위상배열코일 모델을 정확하게 일치시킴으로써, 각기 코일 소자의 공간적 감도를 평가할 때 모의실험 결과와 촬영실험 결과 사이 정확한 비교가 가능하게 되었다. 모의실험과 실제 촬영실험에는 36 채널의 헬멧형 위상배열코일을 사용하였다. MRI 촬영 대상체로는 FDTD 모의실험의 모델과 같은 크기와 형상을 가진 원통형 팬텀을 사용하였다. 개발한 프로그램에서는 위상배열코일의 성능을 편리하게 평가하기 위해 관심 코일 소자를 쉽게 선택할 수 있게 하였다. 결론: 개발한 위상배열코일 성능 검증 프로그램은 위상배열코일의 개발 및 정기적인 유지보수에 사용될 수 있을 것으로 기대한다.

뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성 (Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2)

  • 이세지;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.51-57
    • /
    • 2016
  • 뇌 자기공명영상(Magnetic Resornance Imaging; MRI)에서 검사 중 발생되는 소음을 줄이기 위한 기법으로 경사 파형을 변경한 Quiet $T_2$-weighted Turbo Spin-Echo(이하 Q-$T_2$)와 일반적으로 사용되는 $T_2$-weighted Turbo Spin-Echo(이하 $T_2$) 영상의 소음수준 및 영상의 질을 비교하여 그 유용성을 알아보고자 하였다. 3.0T MR 기기로 뇌 MR 검사를 받은 60명(남자 29명, 여자 31명, 평균 연령 60.1세)의 환자를 대상으로 하였다. Q-$T_2$$T_2$ 각각의 영상에서 소음 및 심박동수를 측정하였다. 정량적 분석은 Q-$T_2$$T_2$의 SNR, CNR, SIR 값을 측정한 뒤 독립표본 T검정을 이용하여 통계적 분석을 하였다. 정성적 분석은 Q-$T_2$$T_2$의 전체적인 영상의 질에 대하여 육안으로 평가하였다. 평가는 5점 척도로서 우수(excellent) 5점, 양호(good) 4점, 보통(fair) 3점, 불량(poor) 2점, 평가불가(unacceptable) 1점으로 평가하였다. Q-$T_2$$T_2$ 검사 중 평균소음과 peak소음은 Q-$T_2$가 기존 $T_2$에 비해 각각 $15dB_A$, $10dB_A$ 감소하였다. 또한 각각의 검사 중 120초 동안 심박동수의 평균값은 Q-$T_2$에서 더 낮은 값으로 나타났지만 통계적인 유의성은 없었다. 정량적 분석의 결과 CNR과 SIR은 유의한 차이가 없었으며, SNR은 Q-$T_2$가 더 낮은 평균값을 보임으로서 유의한 차이를 보였다(p<0.05). 정성적 분석은 59개의 Q-$T_2$$T_2$ 영상의 질이 동일하게 우수(excellent) 5점으로 평가되었으며, 1개의 영상에서 모션 아티팩트로 인해 양호(good) 4점으로 평가되었다. Q-$T_2$는 기존의 $T_2$와 같이 검사시간 및 진단의 정확도는 동일하지만 소음을 효과적으로 감소시킬 수 있으며, 이로인하여 환자 편의를 향상시킬 수 있을 것으로 사료된다.