• Title/Summary/Keyword: certification body

Search Result 86, Processing Time 0.023 seconds

Design and Development of the SNIPE Bus System (초소형위성 SNIPE 본체 설계 및 개발)

  • Kim, Hae-Dong;Choi, Won-Sub;Kim, Min-Ki;Kim, Jin-Hyung;Kim, KiDuck;Kim, Ji-Seok;Cho, Dong-Hyun;Lee, Jaejin
    • Journal of Space Technology and Applications
    • /
    • v.2 no.2
    • /
    • pp.81-103
    • /
    • 2022
  • In this paper, the contents of the design and development process of the 6U micro-satellite Snipe (SNIPE, national name Toyosat; small scale magnetospheric and Ionospheric plasma experiment ), which was developed to observe the near-global space environment through polarization flight for the first time in Korea, were described. Snipe performs transversal flight to observe the Earth's surrounding space environment in three dimensions, and aims to simultaneously observe the space plasma density and temperature in the ionosphere, as well as temporal changes in the solar magnetic field and electromagnetic waves. In this way, it was developed by dividing it into a test certification model (EQM) and a flight model (FM) to perform the actual mission for at least six months, away from developing a cube satellite for short-term space technology verification or manpower training. Currently, Snipe, which has completed the development of a total of four FM and completed all space environment tests, is scheduled to launch 2023. In this paper, we introduce the design contents and development process of the Snipe satellite body ahead of launch, and hope that it will be a useful reference for the development of 6U-class micro-satellite for full-scale mission in Korea.

Steel Frame Clamp Deformation and Performance Check based on Clamping Orientation (철골용 클램프 시공방향에 따른 변형 및 성능확인)

  • Mo, Seung-Un;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.161-169
    • /
    • 2022
  • The government [3] specifies steel pipe scaffolding as conventional scaffolding and is promoting the installation of system scaffolding, an integrated work platform, and avoidance of the use of steel pipe scaffolding as much as possible. However, in places where equipment cannot enter, such as power plants and plant sites, places the structure is complex, and places where scaffolding cannot be stacked on the ground, there is no choice but to install steel pipe scaffolding. When installing steel pipe scaffolding on an H-beam structure at a high place, the performance of the steel frame clamp is very important in order to form a work space which workers can work safely. In this study, the displacement magnitude and tensile load of members in each installation direction of the clamp for steel frame were verified through performance tests and structural analysis modeling. As a result, it was confirmed that the performance for each installation direction satisfies the safety certification standard tensile load of 10,000N. Although the performance value is satisfactory, deformation of the attachment pressing bolt was verified and was confirmed to have minimal deformation. Thus, to ensure the load is properly to the attachment body, the clamp for a steel frame must be installed in the direction in which the load is transmitted.

Antimicrobial, antifungal effect and safety verification using BCOP assay of extracts from Coptis chinensis (황련(Coptis chinensis) 추출물의 항균, 항진균 효과와 BCOP 분석을 이용한 안전성 검증)

  • Kim, Eun-Hee;Jang, Young-Ah;Kim, Sol-Bi;Kim, Han-Hyuk;Lee, Jin-Tae
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.3
    • /
    • pp.297-304
    • /
    • 2018
  • Coptis chinensis is used in oriental medicine for soothing, anti-inflammation, antimicrobial and antipyretic properties, and its main ingredient berberine is known to have strong antibacterial activity. In this study, we investigated the anti-microbial effect of hot water extract of Coptis chinensis (CW) on skin related microorganism and the airborne microbe, the antifungal effects of fungi, which are frequently detected in residential environments. CW showed antibacterial effect against Propionibacterium acnes, Staphylococcus aureus and Staphylococcus epidermidis, against the airborne microbe, which was collected in four different places. At the concentration of 100 mg/mL, the antimicrobial activity continued for 42 days, showed heat stability without change in the antimicrobial activity even after heat treatment. The MIC and MBC of CW against S. aureus was 0.03, 0.05 mg/mL, against S. epidermidis was 0.50, 0.75 mg/mL and against P. acne was 0.10, 0.15 mg/mL. As a result of measuring the MIC of four kinds of fungi with high detection frequency in the surrounding environment, Gliocladium virens was 65 mg/mL by determined as MIC which can inhibit one hundred percent of mycelial growth. The concentration 90 mg/mL was determined as MIC against Aureobasidium pullulans and 100 mg/mL against Penicilium pinophilum and Chaetomium globosum. CW was considered a safe extract that showed no irritation even in the ocular mucous membrane irritation evaluation test, a patch test. Therefore, these results suggest that Coptis chinensis has antimicrobial, antifungal and safety on human body and can be applied to the development of materials for cosmetic and residential environment industries.

A Study on Minimum Cabin Crew Requirements for Korean Low Cost Air Carriers

  • Yoo, Kyung-In;Kim, Mun-Kyung
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.291-314
    • /
    • 2018
  • In recent 3 years, Korea's low-cost airlines have expanded their areas of passenger transportation not only to domestic market but also to Japan, China, Southeast Asia and US territory as a total of 6 companies (8 airlines including small air operation business carriers). Currently, three more airlines have filed for air transportation business certification as future low-cost carriers, and this expansion is expected to continue. To cope with the aggressive airline operations of domestic and foreign low-cost carriers and to enhance their competitiveness, each low-cost airline is taking a number of strategies for promoting cabin service. Therefore, the workload of the cabin crew is increased in proportion to the expansion, and the fatigue directly connected with the safety task performance is increased. It is stipulated in the Enforcement Regulations of the Korea Aviation Safety Act that at minimum, one cabin crew is required per 50 passenger seating capacity, and all low cost carriers are boarding only the minimum cabin crew. Sometimes it is impossible for them to sit in a floor level emergency exit for evacuation, which is the main task of the cabin crew, and this can cause confusion among evacuating passengers in the event of an emergency. In addition, if one of the minimum cabin crew becomes incapacitated due to an injury or the like, it will become a serious impediment in performing emergency evacuation duties. Even in the normal situation, since it will be violating the Act prescription on the minimum cabin crew complement, passengers will have to move to another available airline flights, encountering extreme inconvenience. Annex 6 to the Convention on International Civil Aviation specifies international standards for the determination of the minimum number of cabin crew shall be based only on the number of passenger seats or passengers on board for safe and expeditious emergency evacuation. Thereby in order to enhance the safety of the passengers and the crew on board, it is necessary to consider the cabin crew's fatigue that may occur in the various job characteristics (service, safety, security, first aid)and floor level emergency exit seating in calculating the minimum number of cabin crew. And it is also deemed necessary for the government's regulatory body to enhance the cabin safety for passengers and crew when determining the number of minimum cabin crew by reflecting the cabin crew's workload leading to their fatigue and unavailability to be seated in a floor level emergency exit on low cost carriers.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.