Influence of polishing systems on roughness and color change of two dental ceramics

  • Maciel, Lucas Campagnaro;Silva, Carlos Frederico Bettcher;de Jesus, Ricardo Huver;da Silva Concilio, Lais Regiane;Kano, Stefania Carvalho;Xible, Anuar Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.215-222
    • /
    • 2019
  • PURPOSE. To evaluate the polishing effect on roughness and color change of pressed and layering ceramics after immersion in coffee solution. MATERIALS AND METHODS. 88 ceramic discs ($1.0mm{\times}10.0mm$) were manufactured - 44 nano-fluorapatite layering ceramics (IPS e.max Ceram. Group C) and 44 pressed lithium disilicate ceramic discs (IPS e. max Press - Group P). Each group was divided into 4 subgroups according to surface treatments: (G) Glaze, (S) Shofu polishing system (Shofu Inc.), (E) Edenta AG polishing System, (KG) $30-{\mu}m$ diamond granulation tip. Surface roughness (Ra) and color change (${\Delta}E$) measurings after the surface treatments were performed, before and 12 days after the immersion in coffee solution. A samples' qualitative analysis was conducted with a scanning electron microscopy (SEM). Data were statistically-treated with one-way-ANOVA and Duncan's tests, apart from paired t-test and Pearson's correlation test (${\alpha}=5%$). RESULTS. The decrescent order, both for surface roughness (Ra) and ${\Delta}E$ for both ceramics were: KG > E > S > G (P<.05). With exception for PG and CG subgroups, which did not present statistical difference between them, all other pressed ceramics subgroups presented smaller Ra values and greater ${\Delta}E$ values than the layering ceramics subgroups (P<.05). CONCLUSION. Although mechanical polishing systems presented intermediate Ra values, their colors were considered clinically acceptable. There is a strong correlation between the surface roughness and the color change of tested ceramics.

구개부 치조골 결손을 보이는 상악 전치 상실부의 임플란트 심미보철수복: 증례보고 (Esthetic implant restoration in the maxillary anterior missing area with palatal defect of the alveolar bone: a case report)

  • 오재호;강민구;이정진;김경아;서재민
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.291-298
    • /
    • 2017
  • 치조골 폭이 협소한 상악 전치부의 심미적인 임플란트 수복은 임플란트 식립체의 경사각과 위치가 제한되기 때문에 단순한 임플란트 식립만으로는 심미적인 임플란트 보철물을 제작하기 어려운 일이다. 임플란트 보철물이 변연 치은과 조화로운 출현윤곽을 재현하기 위해서는 임플란트 식립체의 이상적인 치조골 내 위치와 식립각이 설정될 수 있어야 하며, 이를 위해서는 종종 임플란트 식립 전 골증대술을 선행하여야 한다. 본 증례는 구개측의 심한 골 결손을 동반한 얇은 치조골 폭을 보이는 상악 전치 상실부에 골증대술을 시행한 후, 임플란트를 식립하여 심미 보철을 시행한 증례이다. 먼저 협측에 과량의 골증대술을 선행하여 불리한 임플란트 식립 위치를 보상할 수 있는 구개측 식립 경사를 확보하였으며, 임시보철물의 외형을 조정하여 인접 치아와 조화로운 변연 치은 높이와 치간 유두를 형성하였다. 최종적으로 지르코니아 코어를 가지는 도재수복물을 이용하여 보철 수복하였고 심미적, 기능적으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

치근단 병소를 가진 치아의 발치 후 즉시 임플란트 식립 및 보철을 통한 심미성 회복 (Immediate implant placement into extraction sites with periapical lesions in the esthetic zone: a case report)

  • 이재영;김지환;한동후
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.191-197
    • /
    • 2012
  • 상악 전치부는 심미적 회복이 강조되는 부위다. 발치 후 치유될 때까지 기다린다면 치조골 흡수와 치간 유두 수축을 방지할 수 없다. 일단 흡수된 조직을 재생하기 위해서는 추가적인 외과적 술식이 필요하고 치료 기간도 많이 소요된다. 발치 전 치조골과 치은 조직이 건강하다면 치주 조직을 보존 유지하기 위해 발치와 동시에 즉시 임플란트 식립을 고려할 수 있다. 특히 건전한 발치와에서의 즉시 임플란트 식립은 여러 논문에서 성공적인 결과를 보였다. 치근단 병소가 존재하는 치아의 발치 후 즉시 임플란트 식립에 대해서는 부정적인 반응을 보이는 연구가 많았으나, 최근에는 확실한 발치와의 육아조직제거와 전신적 항생제 투여 시 성공률이 높다는 결과도 보고되고 있다. 본 증례는 73세 여환으로 상악 좌측 중절치의 포스트-코어와 금속도재관이 탈락되었으며 임플란트 치료를 받고 싶다는 주소로 내원하였다. 치근단 병소와 수직적 치근 파절이 존재하였으나 치근단 병소가 있는 치아에서도 즉시 임플란트 식립의 성공사례가 여러 차례 보고되어 발치 및 즉시 임플란트 식립을 계획하였다. 발치 후 발치와 육아조직제거와 클로르헥시딘 용액 소독 및 tetracycline 용액으로 soaking을 시행한 후 임플란트를 식립하였으며 식립 전 후로 전신적 항생제를 투여하였다. 임플란트를 식립하면서 인상채득하여 2일 뒤 임시 보철물을 장착하였다. 약 6개월 뒤 치경부 형태를 재연하여 최종 인상 채득하였으며 최종 보철물을 장착하였다. 보철물 장착 후 2년까지 치은선이 인접치아와 조화를 이루고 변연골 흡수없이 심미적으로 만족할만한 결과를 얻었기에 보고하는 바이다.

The effect of coloring liquids on the translucency of zirconia framework

  • Tuncel, Ilkin;Eroglu, Erdal;Sari, Tugrul;Usumez, Aslihan
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.448-451
    • /
    • 2013
  • PURPOSE. Translucency of all-ceramic restorations is an important factor which affects the final appearance and esthetic outcome of the restoration. The aim of this study was to evaluate the effect of the shade of coloring liquid on the translucency of zirconia framework. MATERIALS AND METHODS. Thirty zirconium oxide core plate ($15{\times}12{\times}0.5$ mm) were divided into 6 groups of 5 plates each. Each group was classified according to the shade of coloring liquid based on Vita Classic Scale (A2, A3, B1, C2, and D2), and each sample was immersed in coloring liquid for 3 seconds as recommended by the manufacturer, except for the control group. Contrast ratio, as a translucency parameter, was calculated using a spectrophotometer and the data were analyzed with oneway analysis of variance (ANOVA) and Tukey's honestly significant differences (HSD) tests (${\alpha}$=.05). RESULTS. Significant differences in translucency among the control and test groups, and the B1 shaded group and other shades was observed. There were no significant differences among A2, A3, C2, and D2 shaded groups. CONCLUSION. The translucency of the zirconium oxide cores was affected by the coloring procedure and significant differences in the translucency measurements were identified between specific shades.

디지털 인상채득 및 CAD/CAM을 이용한 상악 전치부 보철물 제작과 기존 방식 보철물과의 임상적 비교 (Maxillary anterior all ceramic restoration using digital impression and CAD/CAM)

  • 표세욱;박영범;김지환;문홍석;이근우
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.263-269
    • /
    • 2011
  • 기존 인상채득법에 비해 보다 정확하고 편리한 보철치료를 위하여 최근 디지털 인상채득법이 개발되고 있다. CAD/CAM과 더불어 디지털 인상채득법의 도입으로 치과 진료의 디지털화가 현실로 다가오는 시점에서, 본 증례는 디지털 인상채득 후CAD/CAM으로 제작한 보철물과 기존 방식으로 인상채득하여 제작한 보철물의 차이점을 임상적으로 알아보고 그 과정을 자세히 소개하였다. 22세 여자 환자가 상악 좌측 중절치의 변색과 모양 개선을 위해 보철 치료를 주소로 내원하였다. 8년전 외상으로 인해 근관치료 및 포스트를 시행 후, 치관 결손부는 레진으로 수복한 상태였으며, 전부도재관 치료계획 수립 후 환자의 동의 하에 서로 다른 방식의 2가지 보철물을 제작하여 비교해 보기로 하였다. 환자의 지대치를 기준으로 각 보철물의 내면적합도를 비교해본 결과, 두 보철물 모두 임상적으로 수용할만한 결과를 얻을 수 있었으나 아직까지는 기존 방식 보철물에 비해 디지털 방식의 보철물이 내면적합도에 있어서 더 큰 오차를 보임을 알 수 있었다.

Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.71-78
    • /
    • 2014
  • PURPOSE. The objective of this study was to evaluate the clinical acceptability of all-ceramic crowns fabricated by the digital veneering method vis-$\grave{a}$-vis the traditional method. MATERIALS AND METHODS. Zirconia specimens manufactures by two different manufacturing method, conventional vs digital veneering, with three different thickness (0.3 mm, 0.5 mm, 0.7 mm) were prepared for analysis. Color measurement was performed using a spectrophotometer for the prepared specimens. The differences in shade in relation to the build-up method were calculated by quantifying ${\Delta}E^*$ (mean color difference), with the use of color difference equations representing the distance from the measured values $L^*$, $a^*$, and $b^*$, to the three-dimensional space of two colors. Two-way analysis of variance (ANOVA) combined with a Tukey multiple-range test was used to analyze the data (${\alpha}$=0.05). RESULTS. In comparing means and standard deviations of $L^*$, $a^*$*, and $b^*$ color values there was no significant difference by the manufacturing method and zirconia core thickness according to a two-way ANOVA. The color differences between two manufacturing methods were in a clinically acceptable range less than or equal to 3.7 in all the specimens. CONCLUSION. Based on the results of this study, a carefully consideration is necessary while selecting upper porcelain materials, even if it is performed on a small scale. However, because the color reproducibility of the digital veneering system was within the clinically acceptable range when comparing with conventional layering system, it was possible to estimate the possibility of successful aesthetic prostheses in the latest technology.

$Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구 (The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients)

  • 송영균;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.470-478
    • /
    • 2008
  • 완전도재 수복물은 뛰어난 심미성을 가지고 있어, 환자들의 심미적 욕구를 충족시킬 수 있다. 이러한 도재관을 제작함에 있어 CAD/CAM 시스템을 이용하는 것은 시간과 비용을 절약할 수 있는 장점을 가지고 있으며, 정밀도 또한 점차 높아지고 있다. 특히 변연적합도는 수복물의 성공 여부에 중요한 요소이고, 이 분야에 대한 실험적 연구는 많이 보고되고 있으나 임상적인 연구는 아직 미흡한 실정이다. 본 연구에서는 CAD/CAM 시스템의 하나인 $Procera^{(R)}$ AllCeram 시스템의 변연적합도를 실제 환자의 수복물 상에서 측정함으로써 임상에 사용되는 CAD/CAM 시스템의 변연적합도를 연구하고자 하였다. 단국대학교 치과병원 보철과에 내원한 56명, 101개의 지대치에 대해 코핑 상태와 최종수복물의 변연오차를 입체광학현미경으로 측정하고 비교분석하여 다음과 같은 결과를 얻었다. 실험 결과, 코핑의 변연오차 ($53.84{\pm}38.83\;{\mu}m$)보다 최종 수복물에서의 변연오차 ($45.82{\pm}30.84\;{\mu}m$)가 더 낮은 값을 나타났으며, 이는 통계적으로 유의한 차이가 있었다 (P < .05). 각 측정 지점간 비교에서 역시 모든 변연에서 코핑 의 변연오차가 최종 수복물에서의 변연오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 구치부의 변연오차는 전치부의 변연오차보다 더 높은 값을 나타냈으나, 통계적으로 유의한 차이는 없었다. 설측 변연의 경우, 근심, 원심, 순측 변연의 오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 이상의 결과로 보아 $Procera^{(R)}$ 시스템의 Allceram 관의 변연적합도는 임상적 허용 범위 내에 있었으며, 특히 도재 축성후 변연적합도 는 더 우수해지는 것으로 나타났으며, 각 변연 중 설측 변연의 오차가 가장 큰 것은 주모형의 정보 입력시 순측 부위의 특성상 일어나는 오류로 사료된다. $Procera^{(R)}$ 시스템 Allceram 관 수복시 설측 변연에 더욱 주의를 기울이는 것이 좋은 변연적합을 얻는 데 도움이 될 것으로 사료되며, 앞으로 주모형 변연 부위의 변곡 정도에 따른 변연오차에 대한 연구가 필요할 것으로 사료된다.

도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교 (Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR)

  • 유지성;김지환;김선재;이용근;심준성
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.416-423
    • /
    • 2009
  • 연구목적: 이번 연구의 목적은 PLV 수복물의 접착 시 사용되는 광중합형 레진 시멘트의 중합도를 Fronrier transform infrared spectroscope로 측정하여 도재의 두께, 광원 및 광조사 시간에 따른 중합도의 차이를 비교하기 위함이다. 연구재료 및 방법: 대조군으로는 1.0 mm의 투명한 slide glass를 사용하였고, 도재 시편은 IPS Empress Esthetic shade ETC1을 선택하여 0.5, 1.0, 1.5 mm의 두께로 제작하였다. 레진 시멘트는 광중합형 레진 시멘트인 Rely $X^{TM}$ Veneer Shade A3를 사용하였다. 광원으로는 Quartz Tungsten Halogen (QTH), Light Emitting Diode (LED), Plasma arc curing (PAC) 광중합기를 사용하였다. 레진 시멘트의 중합도는 FT-IR과 OMNIC 프로그램을 이용하여 측정하였다. 통계분석은 one-way ANOVA와 Tukey HSD를 이용하였다 ($\alpha$=0.05). 결과: 대조군에서 QTH와 LED로 광중합을 시행하였을 때 PAC로 광조사를 시행한 경우보다 중합도가 높았다. QTH와 LED로 광조사를 시행한 경우, 대조군과 0.5 mm, 1.0 mm, 1.5 mm의 도재 두께에서 유의차를 보이지 않았다. 반면, PAC로 광조사를 시행한 결과, 도재의 두께가 1.5 mm인 실험군의 중합도가 대조군과 0.5 mm에서 보다 통계적으로 유의하게 낮은 결과를 보인다 (P<.05). 두께가 1.0 mm의 도재와 LED 광중합기로 광조사하여 중합도를 비교한 결과, 20초간 광조사를 시행하였을 때와 비교하여 80초와 160초간 광조사를 시행한 경우 통계적으로 유의하게 중합도의 평균값이 높았다 (P<.05). 결론: 이번 연구의 한계 내에서, 도재의 두께가 0.5-1.5 mm 이내의 PLV 접착 시, PAC 중합기의 사용은 고려되지 않으며, QTH나 LED로 40초 이상 중합한다면 광중합형 레진 시멘트를 사용할 수 있다. 또한, 광중합형 레진 시멘트를 LED로 중합시킬 경우, 광조사 시간의 증가가 중합도의 증가와 비례하지 않으며, 일정시간 이상의 광조사가 중합도에 큰 영향을 끼치지 않는다.

구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구 (A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications)

  • 김정호;이재봉
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.156-163
    • /
    • 2009
  • 연구목적: 4종 구치용도재관(Full-porcelain-occlusal-surfaced PFG, Half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon)과 선별된 한국음식의 fracture load와 dynamic cyclic load를 측정하여 구치용 도재관에 파절을 일으킬 가능성이 있는 한국음식을 선별하는데 있다. 연구재료 및 방법: 4종의 각 porcelain 보철물 system 당 15개의 축대칭을 이루는 crown을 제작했다. 이때 occlusal reduction은 1.5-2.0 mm로 했다(중심부 1.5 mm, 교두부 2.0 mm). 각 15개의 시편의 교합면 중앙부에 직경 5 mm의 stainless steel ball을 위치시킨 후 Instron 4465 universal testing machine(Instron, Norwood, MA USA)을 이용하여 5 mm/min의 crosshead speed로 수직 부하를 주어 파절을 일으키는 최대 부하(N)를 기록했다. 이후, 한국음식 중 삶은 게, 닭(뼈포함), 소갈비(뼈포함), 마른 오징어, 건멸치, 사탕, 호두껍질을 표본으로 설정하고 이들을 파절시키는 최대 부하(N)를 universal testing machine(Instron 4465) 에서 측정하여 기록했다. 각 항목당 15번을 측정했다. 음식물을 파절시킬 때 필요한 최대부하와 각 보철물의 파절저항을 비교하여 한국의 식습관과 도재를 이용한 보철물 파절의 상관관계를 조사하였다. fracture loads는 analysis of variance 와 Post Hoc tests를 이용해서 분석하였다($\alpha$=0.05). 차후에 위에서 얻은 결과를 바탕으로 Hydraulic Dynamic Fatigue Testing Machine(858 Bionix II, MTS systems, Eden Prairie, MN USA)를 이용하여 4종의 각 porcelain 보철물 system당 5개의 crown에 14Hz Cyclic Load를 가하여 crown에 파절을 일으키는 masticatory cycle수를 알아 보았다. Load 수치는 41.0 N(건멸치 파절강도), 169.0 N(마른오징어 파절강도), 382.9 N(닭뼈 파절강도), 2224.8 N(사탕 파절강도)로 설정하였다. 결과: 95% confidence intervals for mean fracture load는 2599.3-2809.1 N(완전도재교합면 PFG), 3689.4-3819.9 N(반도재교합면 PFG), 1501.2-1867.9 N(Ice Zirkon), 803.2-1188.5 N(Empress 2)로 나왔고 95% confidence intervals for dynamic cyclic load on fracture는 instron 상에서 도재보철물에 파절을 일으키지 않은 load인 2224.8 N(사탕 파절강도)와 382.9 N(닭뼈 파절강도)로 실험했을 때, 2224.8 N에서 4796.8-9321.2 cycles(완전도재교합면 PFG), 2224.8 N에서 881705.1-1143565.7 cycles(반도재교합면 PFG), 382.9 N에서 979993.0-1145773.4 cycles(Ice Zirkon), 382.9 N에서 564.1-954.7 cycles(Empress 2)로 나왔다. 결론: 통계학적으로 유의할 만한 차이가 그룹들 간 fracture load에서 나타났다. 한국음식물 중 소갈비(뼈포함)와 사탕(자두맛캔디)은 구치용 도재보철물을 파절시킬 가능성이 있는 음식물로 밝혀졌다. 단일수직부하에서는 파절이 생기지 않는 경우라 할지라도 dynamic cyclic load를 줄 경우 일정 주기 후에 파절이 생기는 결과를 얻을 수 있었다.

CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구 (Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay)

  • 백철우;박철우;박준섭;류재준
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.20-26
    • /
    • 2013
  • 연구 목적: 본 연구는 최근 심미수복에 주로 사용되는 CAD/CAM 세라믹 인레이와 각종 레진 시멘트간의 결합강도를 알아보고자 하였다. 연구 재료 및 방법: 원기둥 모양의 세라믹 블록(높이: 5 mm, 직경: 3 mm)을 Cerec3로 제작하고, 총 90개의 우식이 없는 대구치의 상아질 표면에 세 종류의 레진 시멘트(Unicem$^{(R)}$, Biscem$^{(R)}$, Variolink II$^{(R)}$)를 사용하여 각각 제조업체의 지시에 따라 접착했다. 90개의 시편을 레진 시멘트의 종류에 따라 3개의 군으로 나누고, 각 군의 절반은 $5-55^{\circ}C$, 5,000 cycle 조건 하에서 thermocycling을 시행하였고, 다른 절반은 시행하지 않았다. 모든 시편은 결합강도를 측정하기 전에 $37^{\circ}C$ 생리 식염수에 24시간 동안 보관되었다. 전단결합강도는 만능시험기를 이용하여 0.5 mm/min의 cross head speed로 측정하였다. 결과 값은 t-test 및 one-way ANOVA를 사용하여 통계 분석하였다. 결과: Unicem$^{(R)}$ 군의 전단결합강도가 thermocycling 후에 약간 감소했으나 3 개의 군 중 가장 높은 결합 강도를 보였다. Unicem$^{(R)}$ 및 Valiolink II$^{(R)}$ 군의 전단결합강도가 thermocycling에 영향을 받았지만 Biscem$^{(R)}$은 영향을 받지 않았다(P<.05). Thermocyling 전에는 3개의 군 간의 결합강도에 유의한 차이가 없었지만, thermocyling 후에는 Unicem$^{(R)}$과 Valiolink II$^{(R)}$ 군 간에 유의한 차이가 있었다(P<.05). 결론:CAD/CAM 세라믹 인레이 수복물을 치아에 접착할 때, etch-and-rinse 레진 시멘트인 Valiolink II$^{(R)}$ 대신self-adhesive 레진 시멘트인 Unicem$^{(R)}$과 Biscem$^{(R)}$을 사용해도 임상적으로 유용하다.