• 제목/요약/키워드: center symmetry

검색결과 257건 처리시간 0.038초

Construction of bivariate asymmetric copulas

  • Mukherjee, Saikat;Lee, Youngsaeng;Kim, Jong-Min;Jang, Jun;Park, Jeong-Soo
    • Communications for Statistical Applications and Methods
    • /
    • 제25권2호
    • /
    • pp.217-234
    • /
    • 2018
  • Copulas are a tool for constructing multivariate distributions and formalizing the dependence structure between random variables. From copula literature review, there are a few asymmetric copulas available so far while data collected from the real world often exhibit asymmetric nature. This necessitates developing asymmetric copulas. In this study, we discuss a method to construct a new class of bivariate asymmetric copulas based on products of symmetric (sometimes asymmetric) copulas with powered arguments in order to determine if the proposed construction can offer an added value for modeling asymmetric bivariate data. With these newly constructed copulas, we investigate dependence properties and measure of association between random variables. In addition, the test of symmetry of data and the estimation of hyper-parameters by the maximum likelihood method are discussed. With two real example such as car rental data and economic indicators data, we perform the goodness-of-fit test of our proposed asymmetric copulas. For these data, some of the proposed models turned out to be successful whereas the existing copulas were mostly unsuccessful. The method of presented here can be useful in fields such as finance, climate and social science.

PZT압전 세라믹스의 종$\cdot$횡파 동시 발생 기구의 해석 (Analysis of Simultaneous Generation Mechanism of P/S Waves with the PZT Piezoelectric Ceramics)

  • 김연보;노용래;남효덕
    • 한국음향학회지
    • /
    • 제14권2호
    • /
    • pp.73-79
    • /
    • 1995
  • 현재 사용중인 초음파 트랜스듀서는 종피 또는 횡피 중 하나를 발생하도록 구성되어 있다. 본 연구는 단일 PZT소자로서 종파와 횡파를 동시에 발생 할 수 있는 2 중 모우드 트랜스듀서 의 초음파 발생 메커니즘을 조사하였다. 분극처리한 압전 세라믹 PZT의 결정구조는 상온에서 hexagonal (6mm) 이다. 트랜스듀서가 종. 횡액를 동시에 큰 강도로 발생하는 최적 절단면을 결정하기 위하여 PZT 소자의 효율을 회전각의 함수로 조사하였다 그리고 선택된 절단면에 대하여 소자의 임피던스 변화를 유한요소법으로 분석하고, pulse-echo 시뮬레이션으로 파형을 관찰하였다. 이론적 결과를 실험을 통해 확인하였다.

  • PDF

Crystal Structure and Molecular Stereochemistry of Novel Polymeric Cu2(DMP)44(DMSO) as a Platform for Phosphate Diester Binding

  • Rafizadeh, Massoud;Tayebee, Reza;Amani, Vahid;Nasseh, Mohammad
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.594-598
    • /
    • 2005
  • Treatment of a solution of $CuCl_2$ in dimethyl phosphate (DMP) with DMSO under nitrogen atmosphere afforded to a light blue fluorescence powder. Slow evaporation of $H_2O$-DMSO solution of this powder resulted in blue-sky crystals of a new polymeric Cu(II) complex, with a unit cell composed of $Cu_2(DMP)_4$(DMSO), (1). The crystal and molecular structure of the complex acquired crystallographically. Compound (1) crystallizes in the monoclinic space group $P2_1$/n with a = 12.8920(11) $\AA$, b = 13.1966(11) $\AA$, c = 14.7926(13) $\AA$, $\alpha$ = 90$^{\circ}$, $\beta$ = 98.943(2)$^{\circ}$, $\gamma$ = 90$^{\circ}$, V= 2486.1(4) ${\AA}^3$, and Z = 4. A square pyramidal environment for the metal center was established by coordination of oxygen atoms of four bridging DMP ligands in the basal positions and binding a tri-centered oxygen atom of DMSO in the apical disposition of Cu(II). The sixth position was also affected by a weak interaction with the sulfur atom of another DMSO. The phosphorous atom in the bridging DMP was arranged in a deformed tetrahedron with (gg) conformation for methyl esters with $C_{2v}$ symmetry.

동축형 인젝터의 미립화 특성 (Atomization Characteristics of shear coaxial twin fluid injector)

  • 한재섭;강경택;김유;김선진
    • 한국분무공학회지
    • /
    • 제5권4호
    • /
    • pp.40-46
    • /
    • 2000
  • To understand the basic the structure of the spray field and to obtain the initial conditions for computational models for shear coaxial twin-fluid injectors. the atomization characteristics under different flow and geometric conditions were examined. The spray characteristics such as SMD, mean axial and radial velocities, Dia. of droplets and volume flux with a P.D.P.A. Water and nitrogen gas under atmospheric conditions were used as a test fluids. The drops produced by shear coaxial injectors continue to disintegrate along the spray axis and decrease their sizes. SMD was the maximum at the spray center of spray and decreased with increasing radial distance. The results of this parametric study showed that SMD decreased with increasing gas injection velocity as well as with decreasing liquid injection mass flow rate, The relative velocity between gas and liquid flow played a significant role resulted in decreasing SMD and in spreading the spray. Recessing the liquid orifice resulted decreasing SMD and a spreading the spray. Recess of liquid orifice by 5.0mm showed best atomization characteristics in this experiment. Although drop diameter changes, shear coaxial injector sprays had constant velocity and exhibited a high degree of radial symmetry.

  • PDF

유속 감지를 위한 실리콘 유량센서의 설계 및 제작 (Design and Fabrication of Silicon Flow Sensor For Detecting Air Flow)

  • 이영주;전국진;부종욱;김성태
    • 전자공학회논문지A
    • /
    • 제31A권5호
    • /
    • pp.113-120
    • /
    • 1994
  • Silicon flow sensor that can detect the velocity and direction of air flow was designed and fabricated by integrated circuit process and bulk micromachining technique. The flow sensor consists of three-layered dielectric diaphragm, a heater at the center of the diaphragm, and four thermopiles surrounding the heater at each side of diaphragm as sensing elements. This diaphragm structure contributes to improve the sensitivity of the sensor due to excellent thermal isolation property of dielectric materials and their tiny thickness. The flow sensor has good axial symmetry to sense 2-D air flow with the optimized sensing position in the proposed structure. The sensor is fabricated using CMOS compatible process followed by the anisotropic etching of silicon in KOH and EDP solutions to form I$\mu$ m thick dielectric diaphragm as the last step. TCR(Temperature Coefficient of Resistance) of the heater of the fabricated sensors was measured to calculate the operating temperature of the heater and the output voltage of the sensor with respect to flow velocity was also measured. The TCR of the polysilicon heater resistor is 697ppm/K, and the operating temperature of the heater is 331$^{\circ}C$ when the applied voltage is 5V. Measured sensitivity of the sensor is 18.7mV/(m/s)$^{1/2}$ for the flow velocity of smaller than 10m/s.

  • PDF

TLC 비접촉 온도측정과 중력장에서 열모세관 현상 구명 (A Measurement of Temperature by TLC without Contact and A Study of Thermocapillary Flow under Ground-based Conditions)

  • 엄용균;유재봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1071-1075
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wail and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

Correction of the deviated tip and columella in crooked nose

  • Suh, Man-Koon
    • Archives of Plastic Surgery
    • /
    • 제47권6호
    • /
    • pp.495-504
    • /
    • 2020
  • The primary procedural components of deviated nose correction are as follows: osteotomy to correct bony deviation, septal deviation correction, manipulation of the dorsal septum to correct upper lateral cartilage deviation, and correction of functional problems (manipulation for correction of internal valve collapse and hypertrophy of the inferior turbinate). The correction of tip and nostril asymmetry cannot be overemphasized, because if tip and nostril asymmetry is not corrected, patients are unlikely to provide favorable evaluations from an aesthetic standpoint. Tip asymmetry, deviated columella, and resulting nostril asymmetry are primarily caused by lower lateral cartilage problems, which include deviation of the medial crura, discrepancy in the height of the medial crura, and asymmetry or deformity of the lateral crura. However, caudal and dorsal septal deviation, which is a more important etiology, should also be corrected. A columellar strut graft, correction of any discrepancy in the height of the medial crura, or lateral crural correction is needed to correct lower lateral cartilage deformation depending on the type. In order to correct caudal septal deviation, caudal septal shortening, repositioning, or the cut-and-suture technique are used. Surgery to correct dorsal septal deviation is performed by combining a scoring and splinting graft, a spreader graft, and/or the clocking suture technique. Moreover, when correcting a deviated nose, correction of asymmetry of the alar rim and alar base should not be overlooked to achieve tip and nostril symmetry.

Spectral and Geometrical Study of Two Cadmium Complexes, mer-R,S-[Cd(aepn)2]X2 (X: I-, Cl-, aepn: N-(2-Aminoethyl)-1,3-propanediamine) Supported by Solution Experiments

  • Hakimi, Mohammad;Mardani, Zahra;Moeini, Keyvan
    • 대한화학회지
    • /
    • 제57권4호
    • /
    • pp.447-454
    • /
    • 2013
  • In this research, two new complexes of N-(2-aminoethyl)-1,3-propanediamine (aepn), $[Cd(aepn)_2]I_2$ (1) and $[Cd(aepn)_2]Cl_2{\cdots}H_2O$ (2), were prepared and identified by elemental analysis, FT-IR, Raman spectroscopy and single-crystal X-ray diffraction. Geometry around the cadmium atom in two complexes by coordination of six nitrogen atoms of two aepn is distorted octahedral. If distortion in the mer-$[Cd(aepn)_2]^{2+}$ cation is disregarded, it has a $C_2$ axis and $C_2$ symmetry. The cyclic voltammetry experiments were carried out to study the complexation process. Two structural surveys on coordination modes and complexes of aepn are presented. A study was carried out using CSD data to estimate the averages of bond lengths for different types of the Cd-N bonds. It was found that the intermolecular $N-H{\cdots}I$, $C-H{\cdots}I$ hydrogen bonds in 1 and $N-H{\cdots}Cl$, $N-H{\cdots}O$, $C-H{\cdots}O$, $O-H{\cdots}Cl$ in 2 stabilized the crystal networks.

TLC 를 이용한 사각공동내의 열전도 영역에 기포의 형성으로 인한 열전달 현상 구명 (A Study of Heat Transfer Phenomena due to a Formed Gas Bubble under Heat-Conduction Domain in A Closed Square Cavity)

  • 엄용균;유재봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.85-89
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wall and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

Supporter to Rectifying the Asymmetric Sitting Posture of Post Stroke

  • Lee, In-Hee;Choi, Jin-Ho;Park, Sang-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제23권3호
    • /
    • pp.43-47
    • /
    • 2011
  • Purpose: This study determined the best adjustable height supporter for stroke patients in wheelchairs for the maintenance of a symmetric sitting posture. Methods: Thirty-one stroke participants and 20 age-matched control participants were recruited. The enrolled participants were evaluated by the Force Sensitive Application (FSA) System that was used to assess weight shift and symmetry in wheelchair sitting and assess the symmetric index (SI) of subjects according to 1, 2 and 3 cm height supporters. Results: When a 1 cm height supporter was applied to the paretic side of stroke survivors, sitting postures of stroke patients were significantly more symmetrical (p<0.01). Cross tabulation between the SI of wheelchair sitting and that of the paretic side of stroke patients caused? by a 1 cm supporter showed that 21 SIs of 26 stroke patients were improved by a 1 cm supporter to the paretic side (k=0.26, p<0.01). Conclusion: The findings of the present study demonstrate that stroke patients can maintain a more symmetrical sitting posture (than is possible when simply sitting in a wheelchair seat) if a 1 cm supporter is applied to the paretic side of stroke patients.