• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.041 seconds

A Study on the Path Loss of Underwater Acoustic Channel Based on At-sea Experiment at the South Sea of Korea (남해 실해역 시험 기반 수중음향채널 경로손실에 관한 연구)

  • Kim, Min-Sang;Lee, Tae-Seok;Cho, Yong-Ho;Im, Tae-Ho;Ko, Hak-Lim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.3
    • /
    • pp.405-411
    • /
    • 2020
  • Recently, studies on underwater communication, related to the development of underwater resources, disaster monitoring and defense, have been actively carried out. In the design of wireless communication systems, path loss is the most important information to derive a link budget that is required to guarantee communication reliability by calculating received power level for the given communication link. The underwater acoustic channel have different characteristics according to geographical location and relevant environmental factors such as water temperature, depth, wave height, algae, and turbidity. Subsequently, many research institutes aiming to develop underwater acoustic communication systems are researching actively on the underwater acoustic channels in various sea areas. In Korea, however, studies on the path loss of the acoustic channel are still insufficient. Therefore, in this study, the path loss of the acoustic channel are studied based on measurement data of the at-sea experiment conducted at Geohae-do, southern sea of Korea.

A case of treatment denture and implant-assisted removable partial denture in a patient with collapsed occlusion caused by partial loss of posterior and anterior teeth (편측 구치 및 전치 상실로 인한 교합 붕괴 환자에서 치료 의치와 임플란트 보조 국소의치를 이용한 수복 증례)

  • Ahn, Hye-Bin;Lee, Keun-Woo;Lee, Yong-Sang;Yim, Sun-Young;Kim, Sung Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.110-118
    • /
    • 2022
  • Multiple tooth loss can cause disharmonious occlusial plane, loss of vertical dimension and deflection of mandibular movement. Therefore, restoring proper vertical dimension and occlusion in the centric relation is an important treatment goal. Implant-assisted removable partial denture is a recently used clinical technique, because it increases patient satisfaction by improving retention, support, and stability of conventional denture. The objective of this article is to present a case report describing the fabrication of treatment denture and implant assisted removable partial denture using previously placed implants for a patient with partial loss of posterior support and anterior stop.

Factors Affecting Complete Fetal Loss Following Multifetal Pregnancy Reduction (다태임신 감수술 (Multifetal Pregnancy Reduction) 후 완전태아손실에 영향을 미치는 인자)

  • Kim, Hye-Ok;Kim, Mun-Young;Song, Hyun-Jeong;Park, Chan-Woo;Hur, Girl;Kim, Jin-Yeong;Yang, Kwang-Mun;You, Keun-Jae;Song, In-Ok;Jun, Jong-Young;Koong, Mi-Kyoung;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.30 no.1
    • /
    • pp.39-45
    • /
    • 2003
  • Objective : To identify the factors affecting the complete fetal loss following multifetal pregnancy reduction (MFPR). Design: Retrospective clinical study. Methods : A total of 256 consecutive treatments of MFPR in IVF-ET cycles performed between 1992 through 2000 in Samsung Cheil hospital were analyzed. MFPR was done around 8 weeks of gestation by transvaginal ultrasono-guided aspiration in multiple pregnancies and reduced to singleton or twins. Stepwise logistic regression was performed to identify the factors affecting the final outcome of pregnancy after MFPR. Dependent variable was complete fetal loss and the independent variables were maternal age, paternal age, initial number of gestational sac (iGSNO), initial number of fetal heart beat, the number of remaining live fetus after MFPR, and chorionicity. Results: The total survival rate was 87.9%, and total fetal loss rate after MFPR was 12.1%. Total fetal loss occurred within four weeks from MFPR procedure was 1.95%. Total loss occurred after four weeks of procedure and before 24 gestational weeks was 8.2%. Seventy nine percent (202/256) of pregnancies delivered after 34 weeks of gestation. The survival rate of pregnancies reduced to singleton was significantly higher than that of pregnancies reduced to twins (93.5% vs. 86.7%, p<0.05). The mean ($\pm$SEM) gestational age at delivery was $36.2{\pm}1.0$ and $34.1{\pm}0.5$ weeks for pregnancies reduced to singletons and twins, respectively (p=0.065). Logistic regression analysis revealed that the maternal age, the number of initial gestational sac (iGSNO), and the number of remaining live fetus after MFPR significantly affected the rate of total fetal loss (Z = 0.174'age + 0.596'iGSNO + 1.324'remaining fetuses -12.07), (p<0.05). Conclusions: MFPR seems to be a relatively safe and efficient method to improve the obstetric outcome in high order multiple pregnancy. Because the maternal age, the number of initial gestational sac and the remaining live fetuses after MFPR affect the total fetal loss rate, restriction of the number of transferred embryos according to the age and MFPR to singleton fetus could be considered for the better obstetric outcome in IVF pregnancy.

The Capacity of Applying Electrical Resistance Probe in Natural Corrosion Tests of Vietnam

  • Pham, Thy San;Le, Thi Hong Lien;Le, Quoc Hung
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.98-101
    • /
    • 2003
  • The Electrical Resistance Probe of carbon steel and weight loss coupons were exposed in atmosphere and in the lake water of Hanoi. The comparison of data received by two methods after one year exposure was presented. The correspondence of the data of these methods on the exposure time in both environments showed a capacity of using Electrical Resistance Probe in Vietnamese natural corrosion testing of Carbon steel.

Modeling of pentacene MIS capacitors with admittance measurements and the effects of dispersive charge transport

  • Jung, Keum-Dong;Lee, Cheon-An;Park, Dong-Wook;Park, Byung-Gook;Shin, Hyung-Cheol;Lee, Jong-Duk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.67-69
    • /
    • 2006
  • Capacitance and loss values of pentacene MIS capacitors with different thicknesses are measured as a function of frequency for the modeling of the devices. The equivalent circuit for the ideal MIS capacitor is adopted to model the obtained admittance, so the values of $C_i,\;C_d,\;C_b$, and $R_b$ are determined for each pentacene thickness. In the loss curve, broader loss peaks are observed in measurement than the modeling results regardless of the pentacene thickness. By considering the effects of dispersive charge transport in bulk semiconductor, more accurate modeling results are obtained.

  • PDF

Suppressing Lateral Conduction Loss of Thin-film Cathode by Inserting a Denser Bridging Layer

  • Park, Jung Hoon;Lee, Seung Hwan;Kim, Hyoungchul;Yoon, Kyung Joong;Lee, Jong-Ho;Han, Seung Min;Son, Ji-Won
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.304-307
    • /
    • 2015
  • To reduce the lateral conduction loss of thin-film-processed cathodes, the microstructure of the thin-film cathode is engineered to contain a denser bridging layer in the middle. By doing so, the characteristic crack-like pores that separate the cathode domains in thin-film-processed cathodes and hamper lateral conduction are better connected and, as a result, the sheet resistance of the cathode is effectively reduced by a factor of 5. This induces suppression of the lateral conduction loss and expansion of the effective current collecting area; the cell performance is improved by more than 30%.

A Novel Pixel structure suitable for color scanner embedded TFT-LCD

  • Choo, Kyo-Seop;Kang, Hee-Kwang;Yu, Jun-Hyeok;Do, Mi-Young;Choo, Kyo-Hyuck;Lee, Deuk-Su;Kang, In-Byeong;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1327-1329
    • /
    • 2007
  • We developed a 4 inch (qVGA, 320x240) a-Si TFT LCD which has the function of color scanner. We have designed the novel pixel structure and got good scanning quality with minimum aperture loss. In this new pixel, the sensor capacitance was increased in double without decreasing the aperture loss.

  • PDF

THE ESTHETIC RESTORATION BY OPEN-FACED STAINLESS STEEL CROWN IN PREMATURE LOSS OF MAXILLARY PRIMARY INCISORS (상악 유중절치 조기 상실시 개창 금속관을 이용한 심미적 수복)

  • Lee, Jung-Jin;Kim, Seong-Oh;Lee, Je-Ho;Choe, Hyeong-Jun;Son, Heung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.717-721
    • /
    • 2006
  • Premature loss of maxillary primary incisors often results from early childhood caries (ECC), trauma. While space maintenance in the posterior region is an important consideration when there is early loss of primary molars, the anterior segment appears to be stable, even with the early loss of several incisors, once the primary canines erupt. However, collapse of anterior arch integrity is evident in cases where incisor teeth are in a crowded dentition prior to extraction or lost before the eruption of the primary canines. So, when early loss of maxillary primary incisors, the aim of restoration is esthetics, speech problem, oral habit such as tongue thrusting than space maintenance. This paper reports that the esthetic problem due to premature loss of maxillary incisors can be successfully resolved by soldered open-faced stainless steel crown.

  • PDF

Gamitaeeumjowee-tang for Weight Loss in Overweight and Obese Women with Polycystic Ovary Syndrome: A Retrospective Chart Review (과체중 또는 비만인 다낭성 난소 증후군 환자의 체중감량을 위한 가미태음조위탕의 활용: 후향적 차트 리뷰)

  • Min-jeong Park;Eunjoo Kim;Ji-Myung Ok;Ka-Hye Choi;Young-Woo Lim
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.22 no.2
    • /
    • pp.136-146
    • /
    • 2022
  • Objectives: The objective of this study is to evaluate weight change and analyze adverse events in overweight and obese women with polycystic ovary syndrome (PCOS) who were prescribed with Gamitaeeumjowee-tang. Methods: A retrospective chart review was conducted for medical records of patients with PCOS, who were administered with Gamitaeeumjowee-tang for a period of 12 weeks between January 2019 and December 2021. Outcomes were total weight loss/weight loss rate, the percentage of patients who lost more than 5% and 10% of their baseline weight. Adverse events (AEs) reported by patients were evaluated by severity, causality and system-organ classes. Results: A total of sixty-seven patients were included (mean±standard deviation, Age 28.78±5.25 years, weight 76.78±12.84 kg, body mass index 29.2±4.26 kg/m2). The average total weight loss in PCOS patients was 6.57±3.07 kg and the average weight loss rate was 8.55±3.65%. The percentage of patients with more than 5% and 10% weight loss compared to their baseline weight was 86.56% and 25.37% respectively. The analysis of adverse events are as follows: Causality assessment with World Health Organization-Uppsala Monitoring Centre of AEs showed 'Unlikely' was the most common (71.7%) and severity evaluations with Common Terminology Criteria for Adverse Events showed almost all symptoms were mild (98.9%). Conclusions: Gamitaeeumjowee-tang helps to lose weight of PCOS patients, which is overweight or obese, and no serious adverse events have occurred. Additional well-designed clinical studies are recommended.

The low conversion loss and low LO power V-band MIMIC Up-mixer (낮은 LO 입력 및 변환손실 특성을 갖는 V-band MIMIC Up-mixer)

  • Lee Sang Jin;Ko Du Hyun;Jin Jin Man;An Dan;Lee Mun Kyo;Cho Chang Shik;Lim Byeong Ok;Chae Yeon Sik;Park Hyung Moo;Rhee Jin Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.12
    • /
    • pp.103-108
    • /
    • 2004
  • In this paper, we present MIMIC(Millimeter-wave Monolithic Integrated Circuit) up-mixer with low conversion loss and low LO power for the V-band transmitter applications. The up-mixer was successfully integrated by using 0.1 ㎛ GaAs pseudomorphic HEMTs(PHEMTs) and coplanar waveguide (CPW) structures. The circuit is designed to operate at RF frequencies of 60.4 GHz, IF frequencies of 2.4 GHz, and LO frequencies of 58 GHz. The fabricated MIMIC up-mixer size is 2.3 mmxl.6 mm. The measured results show that the low conversion loss of 1.25 dB when input signal is -10.25 dBm at LO power of 5.4 dBm. The LO to RF isolation is 13.2 dB at 58 GHz. The fabricated V-band up-mixer represents lower LO input power and conversion loss characteristics than previous reported millimeter-wave up-mixers.