• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.034 seconds

Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants

  • Chae, Sung-Wook;Kim, Young-Sung;Lee, Yong-Moo;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Su-Hwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). Methods: The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. Results: A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Conclusions: Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

Chronological Changes in Quality of Life after Distal Gastrectomy for Gastric Cancer

  • Park, Ki Bum;Lee, Seung Soo;Kwon, Oh Kyoung;Chung, Ho Young;Yu, Wansik
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.110-119
    • /
    • 2017
  • Purpose: Patient quality of life (QoL) may be severely disrupted following distal gastrectomy for gastric cancer. This issue should be addressed to improve postoperative care. Materials and Methods: QoL data from the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire, and its gastric cancer-specific module, were administered to 202 patients preoperatively, and 5 years postoperatively. Patients were classified into subgroups based on their answers to each questionnaire item: group I (good), answering "not at all"; group II (fair), answering "a little"; group III (poor), answering "quite a bit" or "very much." Results: At 5 years post-operation, the proportion of patients in group III on the functional scales ranged from 4.3% to 5.7%. The proportions of patients in group III with fatigue, insomnia, diarrhea, and financial difficulties were 8.9%, 9.0%, 11.5%, and 9.1%, respectively. The proportions of patients in group III with anxiety, dry mouth, body image concerns, and hair loss were 12.8%, 10.5%, 9.9%, and 12.6%, respectively. These proportions were less than 5% for other QoL symptom scales/items and for the gastric cancer-specific module. Conclusions: Most patients reported good or fair QoL following surgery. However, symptom management of fatigue, insomnia, diarrhea, anxiety, dry mouth, body image, and hair loss should be specifically targeted for long-term patient care in approximately 10% of patients.

Distribution and Pollution of Heavy metals in Surface sediments from Nakdong River (낙동강 수계 표층 퇴적물의 중금속 분포와 오염도)

  • Kim, Shin;Kim, Jueon;Lee, Kwonchul;Lee, Kyuyeol;Jeon, Hyelyn;Yu, Jaejung;Lee, Injung;Ahn, Jungmin
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.969-980
    • /
    • 2015
  • In order to certificate the distribution and pollution of heavy metal of surface sediments in Nakdong River were collected and analyzed for grain size, water content, ignition loss and heavy metal content. Surface sediments mainly composed of sand(avg. 94.6%) and water content and ignition loss were 20.46%, 1.53% on average. Grain size were relatively fine and organic matter content were relatively high in the Hoichun and Sunakdonggang. Most of heavy metal content(Zn > Cr > Pb > Ni > Cu > Hg) in the Deokcheongang and Sunakdonggang were higher than the other streams. The Igeo were non polluted(less than 0) in all streams and the EF were relatively high in the small stream and PLI were non polluted(less than 1). In addition, organic matter, heavy metal content and pollution were highly correlation with grain size. Surface sediments in study area, heavy metal pollution of the Sunakdonggang were relatively high compared to the other stream but these results were not serious pollution that exceed the sediment pollution evaluation standard of river and lake in Korea and pollution levels adversely affected the majority of benthos were not.

PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System (수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서)

  • Han, Seung Heon;Kim, Tae Un;Jung, Haeng Yun;Ki, Hyun Chul;Kim, Doo Gun;Kim, Seon Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

A Retrospective Analysis of the Effectiveness of Taking Gambi-tang in Overweight and Obese Adults (과체중 및 비만 성인 대상 감비탕 복용 효과에 대한 후향적 분석)

  • Park, Han-song;Yoo, Hee-jung;Ha, Ji-su;Park, Hyun-seo;Seo, Ho-seok;Kim, Jin-won
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.413-422
    • /
    • 2022
  • Objectives: To investigate the weight loss effect of Gambi-tang in obese and overweight adults. Methods: From September 1, 2016 to December 31, 2021, a retrospective chart analysis was conducted on adult men and women who were prescribed Gambi-tang to address obesity and overweight in the National Medical Center (NMC). Partial analysis by age, obesity (Body Mass Index, BMI), duration of dose, and cumulative dose was also conducted. Results: The weight and BMI of the study subjects showed a significant decrease of more than 5% on average before and after treatment. In an analysis of age, significant differences by age could not be confirmed. In the analysis by obesity level, the effect of reducing weight, body fat, and abdominal fat rates in the obese and highly obese groups was greater than in the normal and overweight groups. There was no significant difference by group in the analysis by dosage period. In the analysis by cumulative dose, the greater the cumulative dose up to 1,800 g, the greater the decrease in weight and body fat. The side effect that patients appealed to the most was misjudgment, but not to a serious extent. Conclusions: Gambi-tang has been shown to be effective in weight and body fat loss for both obese and overweight adult men and women.

Inverse behavior of IL-23R and IL-17RA in chronic and aggressive periodontitis

  • Ruiz-Gutierrez, Alondra del Carmen;Rodriguez-Montano, Ruth;Pita-Lopez, Maria Luisa;Zamora-Perez, Ana Lourdes;Guerrero-Velazquez, Celia
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.254-263
    • /
    • 2021
  • Purpose: Periodontitis is associated with a dysbiosis of periodontopathic bacteria, which stimulate the interleukin (IL)-23/IL-17 axis that plays an essential role in the immunopathogenesis of this disease, leading to alveolar bone destruction through receptor activator of nuclear factor κB ligand (RANKL). IL-23 receptor mRNA (IL-23R) has been identified in periodontitis, and IL-17 receptor A mRNA (IL-17RA) and its protein have not yet been evaluated in patients with periodontitis. In this study was measure IL-23R and IL-17RA in gingival tissue (GT) from patients with generalized chronic periodontitis (GCP) and generalized aggressive periodontitis (GAP) and to explore correlations with clinical parameters. Methods: We included 16 healthy subjects (HS), 18 patients with GCP, and 14 with GAP. GT samples were collected during periodontal surgery. Both IL-23R and IL-17RA were detected by enzyme-linked immunosorbent assay. Results: The results were analyzed with Mann-Whitney U test and Spearman' rank correlation coefficients using SPSS version 25.0. We found lower IL-23R levels in patients with GCP and GAP than in HS. Contrarily, we observed higher IL-17RA levels in GCP and GAP patients than in HS. Moreover, we found negative correlations between IL-23R in GT and probing depth and clinical attachment loss (CAL). Likewise, a positive correlation of IL-17RA in GT with CAL was found. Conclusions: The results of these findings suggest that the reverse behavior between IL-23R and IL-17RA in periodontitis patients may also be involved with the activation of RANKL, which promotes alveolar bone loss.

Surgical Strategy for Primary Colorectal Carcinoma and Synchronous Pulmonary Metastasis Resection

  • Kim, Tae Yeon;Cho, Jong Ho;Choi, Yong Soo;Kim, Hong Kwan;Kim, Jhin Gook;Shim, Young Mog
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.37-43
    • /
    • 2022
  • Background: The surgical strategy for single-stage resection of primary colorectal cancer (CRC) and synchronous pulmonary metastases remains a matter of debate. Methods: Perioperative data of patients who underwent single-stage resection of primary CRC and synchronous pulmonary metastases were compared to those of patients who underwent 2-stage resections. The demographic data, number of metastases, type of pulmonary and colorectal resections, operation time, blood loss, postoperative complications, morbidities, mortality, medical costs, and length of hospital stay were analyzed. Results: Twenty-two patients underwent single-stage resection of primary CRC and pulmonary metastases, while 27 patients underwent 2-stage resection. Tumor size and the number of pulmonary metastases were not significantly different between the 2 groups. The extent of pulmonary metastasectomy and abdominal procedures were similar in both groups, as was the thoracic surgical approach (video-assisted thoracic surgery vs. thoracotomy). However, open laparotomy was performed more frequently in the 2-stage group than in the single-stage group (p=0.045), which also had a longer total anesthetic time (p=0.013). The operation time, medical costs, estimated blood loss, complication rates, and severity were similar in both groups, but the length of hospital stay was shorter in the single-stage group (p<0.001). Conclusion: Single-stage colorectal and pulmonary resection shortened the overall hospital stay, with no significant changes in operation time, medical costs, hospital mortality, and morbidity. Therefore, single-stage resection could be a good surgical strategy in selected patients.

Clinical Study on Recurrent Peripheral Facial Nerve Palsy (말초성 안면마비 환자의 재발에 대한 임상적 고찰)

  • Shin, Ye-Ji;Kown, Na-Hyoun;Park, Hyun-Ae;Woo, Hyun-Su;Beak, Yong-Hyeon;Park, Dong-Suk;Koh, Hyung-Kyun
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.29-37
    • /
    • 2009
  • Objectives : This study was performed to categorize and define causes of recurrent peripheral facial nerve palsy. Methods : 54 patients was identified with recurrent peripheral facial nerve palsy among 726 patients who visited the Facial Palsy Center in East-West Neo Medical Center between May 2006 and August 2008. We reviewed the medical records including gender, age, laterality, number of recurrence, primary onset age, interval between recurrences, accompanied disease(e.g. DM, HTN), and axonal loss. Results : Patients whose primary palsy onset was before their second decade had a higher possibility of recurrence and tended to recur more than twice. Double-episode ipsilaterally recurrent group showed definitely worse result of axonal loss compared with non-recurrent group and single-episode ipsilaterally recurrent group. But There was no statistically significant difference between mean axonal loss of the non-recurrent group and single-episode ipsilaterally recurrent group. Conclusions : This study was designed for 54 patients and further studies are necessary.

  • PDF

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

Anew formula CPC22 regulates bone loss, hot flashes, and dysregulated lipid metabolism in ovariectomized postmenopausal mice

  • Hee-Yun Kim;Hyunwoo Jee;Hosong Cho;Dongjun Park;Hyun-Ja Jeong
    • CELLMED
    • /
    • v.13 no.14
    • /
    • pp.15.1-15.15
    • /
    • 2023
  • Background and objective: A new formular CPC22 consists of Cynanchum wilfordii root, Pueraria thomsonii flower, and Citrus unshiu peel and has been developed to improve the postmenopausal symptoms. The research intended to evaluate whether CPC22 would regulate bone loss, hot flashes, and dysregulated lipid metabolism in ovariectomized (OVX) postmenopausal mice. Method: The OVX mice were orally administered with CPC22 daily for 7 weeks. Results: CPC22 regulated OVX-induced bon loss by enhancing serum osteoprotegerin, alkaline phosphatase, and osteocalcin levels and diminishing serum receptor-activator of the NF-κB ligand (RANKL), collagen type 1 cross-linked N-telopeptide, and tartrate-resistant acid phosphatase levels. As a result of CPC22 treatment, notable decreases in tail skin temperature and rectal temperature were observed, along with diminishment in hypothalamic RANKL and monoamine oxidase A levels and enhancement in hypothalamic serotonin (5-HT), norepinephrine, dopamine, 5-HT2A, and estrogen receptor-β levels. CPC22 enhanced levels of serum estrogen and diminished levels of serum follicle-stimulating hormone and luteinizing hormone. CPC22 regulated levels of serum lipid metabolites, including total cholesterol, triglycerides, low-density lipoprotein cholesterol, and high-density lipoprotein cholesterol. Furthermore, CPC22 diminished levels of serum blood urea nitrogen, creatine kinase, alanine transaminase, aspartate aminotransferase, and lactate dehydrogenase and restored vaginal dryness without affecting uterus atrophy index and vagina weights. Conclusion: Therefore, these results indicated that CPC22 improves OVX-induced bone loss, hot flashes, and dysregulated lipid metabolism by compensating for estrogen deficiency without side effects, suggesting that CPC22 may be used for the prevention and treatment of post menopause.