• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.037 seconds

A Case Study of Myoelectric Hand Prosthesis for Upper Extremity Amputee (상지절단자용 전동의수 증례연구)

  • Kang, Ju-Ho;Kim, Myung-Hoe;Lee, Jeong-Weon
    • Physical Therapy Korea
    • /
    • v.2 no.1
    • /
    • pp.80-87
    • /
    • 1995
  • The purpose of this case study was to introduce a myoelectric hand prosthesis for upper extremity amputee and prosthetic training program. Limb loss can result from disease, injury, or congenital causes. Trauma has been increasingly important role as the cause of amputaion in young, vigorous, and otherwise healthy individuals. The higher the level of amputation the greater the functional loss of the part, and the more the amputee must depend on the prostheis for fuction and cosmesis. Myoelectrical control of prostheses is a recent development and has been steadily gaining in clinical use over the past 20 years. Such a prosthesis uses signals from muscle contraction within the stump to activate a battery driven moter that operates specific component fuctions of the prosthesis. This twenty years old male case was operated a right above-elbow amputation due to tracffic accident and admitted to Yonsei Rehabilitaion hospital for the preprosthetic and prosthetic training. The case was able to successfully complete his myoelectric hand prosthesis training in the February of 1995.

  • PDF

Design and Fabrication of Multilayer Chip Band Pass Filter for Mob ice Communication (이동통신용 적층형 칩 대역통과 필터의 설계 및 제작)

  • 윤중락;박종주;이석원;이헌용
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.3
    • /
    • pp.19-24
    • /
    • 1999
  • The multilayer chip band pass filter for mobile communication is fabricated and designed. The size, insertion loss, center frequency and band width of multilayer chip filter are 4.5$\times$4.4$\times$1.8[mm], 3.0[dB] and 700[MHz]$\pm$15[MHz] respectively. The chip filter using $BiNbO_4$with CuO 0.06wt% +$V_2O_5$.lwt% was fabricated by screen printing with Ag electrode after tape casting. Insertion loss and center frequency of the fabricated chip filter are 2.58[dB] and 692.5$\pm$15[MHz] respectively. The center frequency was lower 7.5[MHz] than design result, but other characteristics of chip filter were similar to the ruts ultras of design result.

  • PDF

TreatmentWD Pulse Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Jun-Il;Lee, Sun-Min;Bo, Gak-Hwang;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.36-41
    • /
    • 2012
  • The transcranial magnetic stimulation recharges the energy storing condenser, and sends the stored energy in the condenser to the pulse shaping circuit, which then delivers it to the stimulating coil. The previous types of transcranial magnetic stimulation required a booster transformer, secondary rectifier for high voltages and a condenser for smooth type. The energy storing condenser is recharged by switching the high-voltage direct current power. Loss occurs due to the resistance in the recharging circuit, and the single-pulse output energy in the transcranial magnetic stimulation can be changed because the recharging voltage cannot be adjusted. In this study a booster transformer, which decreases the volume and weight, was not used. Instead, a current resonance inverter was applied to cut down the switching loss. A transcranial magnetic stimulation, which can simultaneously alter the recharging voltage and pulse repeats, was used to examine the output characteristics.

Study on the Microwave Dielectric properties in the Dielectric Rod Resonator Method (유전체 원주공진기법에 의한 고주파 유전특성 측정에 관한 연구)

  • Kim, Kyung-Yong;Kim, Wang-Sup;Choi, Hwan
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.471-481
    • /
    • 1995
  • Measurement factors for the dielectric properties of low dielectric loss materials (tan${\dalta}{\le}10^{-4}$) were investigated using the dielectric rod resonator method. It was shown that the relative conductivity (${\sigma}_{r}$) should be controlled within a 5% to obtain the standard deviations of less than 0.07 for permittivity .epsilon.r and 0.06${\times}10^{-4}$ for tan.delta.respectively. Surface resistivity (R$_s$) could be reduced when the surface roughness of parallelled conducting plate was less than 0.07 .mu.m. Measurement error for the permittivity was $\pm$0.02% independent of probe loop size, whereas the error in Q value was reduced with the decrease in probe loop size and also with the increase in the absolute values of Q. Reliable Q values were determined with the probe loop size of less than 4mm. The accurate for the distance between the measuring probe loop and the sample could be obtained when the insertion loss of resonant frequency ranged -15dB - -30dB.

  • PDF

White Matter Damage and Hippocampal Neurodegeneration Induced by Permanent Bilateral Occlusion of Common Carotid Artery in the Rat: Comparison between Wistar and Sprague-Dawley Strain

  • Kim, Seul-Ki;Cho, Kyung-Ok;Kim, Seong-Yun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.12 no.3
    • /
    • pp.89-94
    • /
    • 2008
  • In order to reproduce chronic cerebral hypoperfusion as it occurs in human aging and Alzheimer's disease, we introduced permanent, bilateral occlusion of the common carotid arteries (BCCAO) in rats (Farkas et al, 2007). Here, we induced BCCAO in two different rat strains in order to determine whether there was a strain difference in the pathogenic response to BCCAO. Male Wistar and Sprague-Dawley (SD) rats (250-270 g) were subjected to BCCAO for three weeks. Kluver-Barrera and cresyl violet staining were used to evaluate white matter and gray matter damage, respectively. Wistar rats had a considerably higher mortality rate (four of 14 rats) as compared to SD rats (one of 15 rats) following BCCAO. Complete loss of pupillary light reflex occurred in all Wistar rats that survived, but loss of pupillary light reflex did not occur at all in SD rats. Moreover, BCCAO induced marked vacuolation in the optic tract of Wistar rats as compared to SD rats. In contrast, SD rats showed fewer CA1 hippocampal neurons than Wistar rats following BCCAO. These results suggest that the neuropathological process induced by BCCAO takes place in a region-specific pattern that varies according to the strain of rat involved.

The Reliability of Optical Fiber Assembly Using Glass Solder

  • Lee, Jong-Jing;Kang, Hyun-Seo;Koh, Jai-Sang
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.147-151
    • /
    • 2004
  • In this study, an optical fiber assembly directly coupled with a laser diode or a photo diode is designed to confirm high reliable optical coupling efficiency of optical transmitter(Tx) and receiver(Rx). The optical fiber assembly is fabricated by soldering an optical fiber and a Kovar ferrule using a glass solder after inserting an optical fiber through a Kovar ferrule. The Kovar which has good welding characteristics is applied to introduce laser welding technique. The glass solder has excellent thermal characteristics such as thermal shift delamination compared with PbSn, AuSn solder previously used usually. Furthermore, the glass solder doesn't need fiber metalization and this enables low cost fabrication. However, the glass soldering is high temperature process over 35$0^{\circ}C$ and the convex shape after solidification due to surface tension causes the stress concentration on optical fiber. The stress concentration on the optical fiber increases the optical insertion loss and possibility of crack formation. The shape of glass solder was designed referring to 2-D Axi-symmetric FEM simulation. To test the mechanical reliability, mechanical vibration test and shock test were done according to Telcorida GR-468-Core protocol. After each test, the optical loss of the stress distributed fiber assembly didn't exceed 0.5 dB, which passes the test.

  • PDF

Reliable design and electrical characteristics of vertical MEMS probe tip (수직형 MEMS 프로브 팁의 신뢰성 설계 및 전기적 특성평가)

  • Lee, Seung-Hun;Chu, Sung-Il;Kim, Jin-Hyuk;Han, Dong-Chul;Moon, Sung
    • Journal of Applied Reliability
    • /
    • v.7 no.1
    • /
    • pp.23-29
    • /
    • 2007
  • Probe card is a test component which is to classify the known good die with electrical contact before the packaging in the ATE (automatic testing equipment). Conventional probe tip was mostly needle type, it has been difficult to meet with conventional type, because of decreasing chip size, pad to pad pitch and pads size increasingly. For that reason, probe cards using MEMS (micro electro mechanical system) technology have been developed for various semiconductor chips. In this paper, Area Array type MEMS Probe tip was designed,, fabricated, and characterized its mechanical and electrical properties. The authors found that good electrical characteristics under $1{\Omega}$ were acquired with gold (Au) and aluminium (Al) pad contact test over 0.5gf and 4gf respectively. And, contact resistance variation under $0.1{\Omega}$ were achieved with 100,000 times of repetition test. And, insertion loss (IS) for high frequency operation was ascertained over 300MHz at -3dB loss.

  • PDF

Symptom Clusters in Women with Gynecologic Cancer (부인암 여성의 증상 클러스터(Symptom Cluster))

  • Chun, Na Mi;Kwon, Jee Yeon;Noh, Gie Ok;Kim, Sang Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.14 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • Purpose: Women with gynecologic cancer often experience various physical and psychological symptoms relating to the cancer and its treatment. The purpose of this study was to identify symptom clusters. Method: A survey was conducted on 184 women with diagnoses of cervical, ovarian or endometrial cancer. Fifty symptoms were assessed for prevalence, severity and interference, and symptom clusters were identified. Cluster analysis was done using SPSS version 12.0. Results: Fatigue was identified as the most prevalent symptom (81.52%), lack of vaginal lubrication (2.26) as the most severe symptom, and lack of vaginal lubrication as the most interfering one (2.15). Identified six clusters were: Anorexia-pain cluster (loss of appetite, taste change, weight loss, appearance change, alopecia, weakness, pain), Fatigue cluster (lack of concentration, lack of memory, fatigue, dry mouth), Urinary-bowel distress cluster (urinary difficulty, constipation), Abdominal discomfort cluster (lower abdominal pain, abdominal pain, bloating), Emotional distress (sadness, anxiety-worry, nervousness, restlessness), and Menopausal cluster (sweating, hot flush, fever). Conclusion: The result of this study provides fundamental data to health care professionals in developing interventions for effective symptom management for women with gynecologic cancer by understanding identified 6 symptom clusters.

  • PDF

Studies on Insulation Effect Related with Thin-Plate Design Factors for Reflective Metal Insulation(RMI) of Nuclear Power Plant (금속단열재 박판의 설계인자별 단열성능 영향 연구)

  • Eo, Minhun;Lee, Sungmyung;Jang, Kyehwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.350-354
    • /
    • 2016
  • Although fibrous insulations are generally used with resistive insulation type, metallic insulation is proper matter to satisfy low head-loss and equipment life when considering the specific condition, especially for Nuclear power plant. Common insulation is resistance insulation with a low thermal conductivity. but RMI is made of sheet plate with low emissivity and closed air space. Thermal radiation is blocked by stainless steel with low emissivity. Thermal conductivity and thermal convection are blocked by closed air space. This study shows the changes and effects of the heat loss according to shape and method of stacking sheet plates inserted into the insulation and analyzed the most optimized way for thermal insulation performance. The result shows that using sheet plate structure through raised and protruding shape processing was the appropriate model to optimize thermal performance. Additionally, insulating performance of RMI improved by placing the sheet plate in a high temperature region intensively.

Loss and Efficiency Dependence of a 6.78 MHz, 100 W, 30 cm Distance Wireless Power Transfer System on Cable Types (6.78 MHz, 100 W, 30 cm 거리 무선 전력 전송 시스템의 전선별 손실 및 효율 비교)

  • Lee, Seung-Hwan;Lee, Byung-Song;Jung, Shin-Myung;Park, Chan-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1651-1657
    • /
    • 2015
  • In MHz operating wireless power transfer systems, skin- and proximity-effect losses in the transmitter and the receiver coils dominate the coil-to-coil efficiency of the system. A Litz-wire was regarded as a common solution for minimizing such Ohmic losses in high frequencies. In this paper, equivalent series resistances of 12 different cables including Litz-wire and copper tubing have been calculated and measured for a 6.78 MHz, 100W, 30 cm wireless power transfer system. It has been shown that the copper tubing has lower resistances compared to the Litz-wire in that frequency and a wireless power transfer system with the copper tubing was able to achieve much higher efficiency than a system using the Litz-wire. Calculations of the resistances and efficiencies were accomplished with analytical equations and those calculations were evaluated by experimental results.