• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.045 seconds

Clinical case reports of cemental tear (백악질 열리의 임상 증례)

  • Park, Jung-Chul;Baek, Do-Young;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.551-556
    • /
    • 2008
  • Purpose: Cemental tear is an uncommon form of root fracture that can lead to rapid localized attachment loss. When it is exposed in the periodontal pocket, it should be removed to prevent accumulation of dental plaque and calculus. Material and Methods: 2 patients were diagnosed as a cemental tear and they were treated with conventional flap operation and subgingival curettage. Additional treatments such as bone graft or guided tissue regeneration were not performed. Result: Symptoms subsided after the treatment. Periodontal pocket has been reduced but no gain of clinical attachment was observed. Remnant of cemental fragment remained after curettage. However, periodontal pocket was stably maintained and there was no recurrence. Conclusion: Periodontal attachment loss associated with cemental tear can be successfully treated with conventional periodontal surgical and nonsurgical procedures.

Accuracy of Free Space Path Loss and Matched Filter Gain Approximated by Using Passband Rectangular Pulse for Ultra Wideband Radio Systems

  • Supanakoon, Pichaya;Tanchotikul, Suchada;Tangtisanon, Prakit;Promwong, Sathaporn;Takada, Jun-Ichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.223-226
    • /
    • 2004
  • This paper analyzes the accuracy of free space path loss and matched filter gain approximated by using a passband rectangular pulse for ultra wideband (UWB) radio systems. The example causal signal, a modulated Gaussian pulse with the same center frequency and frequency bandwidth of the passband rectangular pulse, is used to consider the accuracy. The path loss and matched filter gain of the modulated Gaussian pulse are simulated for the reference results. The UWB free space path loss is shown and is compared with that obtained from simulation and Friis' transmission formula. The UWB matched filter gain is shown and compared with simulation results. From the results, we can see that the UWB path loss formula is more accurate than the Friis' transmission formula. The results from the UWB free space path loss and matched filter gain formulas agree with the simulation. Then, these free space path loss and matched filter gain formulas approximated by using a passband rectangular pulse are appropriate for UWB system.

  • PDF

A Study on the Loss Reduction Method of Reinforcing Bar through Case Study

  • Park, U-Yeol;Jung, Hyeon-Ok;Kang, Tai-Kyung;Cho, Hun-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.123-132
    • /
    • 2010
  • Rebar work accounts for approximately 30% of the total construction costs for rebars and concrete. Recently, the high rising prices of rebars have become one of the principle factors of rising construction costs. Therefore, construction companies are putting much effort into loss reduction of rebars. Consequently, in this study, we wished to present loss reduction methods of rebars before the preparation of the placing drawings. To devise such methods, we collected previous case studies and analyzed methods that were applied for loss reduction. As a result of the analysis, we were able to find the following methods for loss reduction of rebars: method of reducing the number of splices at the mat foundation, method of reducing splice length at the internal columns or walls of the underground parking lot, method of reducing cap-ties of internal beams of basement floors excluding perimeter beams, and method of reducing anchorage length at the internal column or wall of the underground parking lot. Based on those analysis results, we presented our own loss reduction methods of rebars. Applying our methods resulted in considerable loss reduction.

Usefulness of Estimated Height Loss for Detection of Osteoporosis in Women

  • Yeoum, Soon-Gyo;Lee, Jong-Hwa
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.758-767
    • /
    • 2011
  • Purpose: This study was done to examine the threshold value of estimated height loss at which the risk of osteoporosis increases and to verify its discriminative ability in the detection of osteoporosis. Methods: It was conducted based on epidemiological descriptive methods on 732 Korean women at a public healthcare center in Seoul between July and November 2010. ANOVA, Pearson correlation, logistic regression analysis and receiver operating characteristics (ROC) curve were used for data analysis. Results: There was an age-related correlation between bone mineral density (lumbar spine: F=37.88, p<.001; femur: F=54.27, p<.001) and estimated height loss (F=27.68, p<.001). Estimated height loss increased significantly with decreasing bone mineral density (lumbar spine: r=-.23, p<.001; femur: r=-.34, p<.001). The odds ratio for the point at which the estimated height loss affects the occurrence of osteoporosis was found to increase at a cut-off value of 2 cm and the area under ROC curve was .71 and .82 in lumbar spine and femur, respectively. Conclusion: The optimal cut-off value of the estimated height loss for detection of osteoporosis was 2 cm. Height loss is therefore a useful indicator for the self-assessment and prognosis of osteoporosis.

An Empirical Indoor Path Loss Model for Ultra-Wideband Channels

  • Ghassemzadeh, Saeed-S.;Greenstein, Larry-J.;Kavcic, Aleksandar;Sveinsson, Thorvardur;Tarokh, Vahid
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.303-308
    • /
    • 2003
  • We present a statistical model for the path loss of ultrawideband (UWB) channels in indoor environments. In contrast to our previously reported measurements, the data reported here are for a bandwidth of 6GHz rather than 1.25GHz; they encompass commercial buildings in addition to single-family homes (20 of each); and local spatial averaging is included. As before, the center frequency is 5.0GHz. Separate models are given for commercial and residential environments and, within each category, for lineof sight (LOS) and non-line-of-sight (NLS) paths. All four models have the same mathematical structure, differing only in their numerical parameters. The two new models (LOS and NLS) for residences closely match those derived from the previous measurements, thus affirming the stability of our path loss modeling. We find, also, that the path loss statistics for the two categories of buildings are quite similar.

An Experimental Study on The Frictional Loss of Stress in The Prestressing Tendons (PS 긴장재의 마찰손실량에 관한 실험적 연구)

  • 정배근;한경봉;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.417-422
    • /
    • 2000
  • In prestressed concrete structures, determining serviceability and safety it is important to exactly calculate effective prestress force acting on structures. for the determination of effective prestress force, friction loss of the prestressing tendon should be decided exactly, but it is very difficult to measure the exact prestress force on the site and there is no actual field data. Therefore the friction loss coefficient recommended by the specification is not verified. in this paper, the friction loss standard PSC-Beam will be investigated, and is will be found what kind of relationship between the specification and the site. The results from this study can be summarized as follows. For jacking at both ends, actual intial prestress force in the center section of PCS-Beam was about 1.61% larger than theoretical initial prestress force and for hacking at one end, actual initial prestress force was approximate 4.9% lower than theoretical initial prestress force. Thus, for the exact calculation of friction loss, friction coefficient should be modified according to jacking methods.

  • PDF

Effect of Test Board on Insertion Loss of GHz Multilayer LC-Filter (GHz용 적층 LC필터의 삽입손실에 대한 Test Board의 영향)

  • Chun, Myoung-Pyo;Cho, Jung-Ho;Kim, Byung-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.173-175
    • /
    • 2005
  • The effects of PCB Board on the filter characteristics such as insertion loss and transmission characteristics were investigated for the measurement of 5GHz LC filter. Insertion loss measured with PCB Board of Teflon is 0.3 dB lower in comparion with FR-4. The filter characteristics measured in the passband were different from the calculated results. In comparison with the calculated value, the measured value shows that center frequency is 20MHz lower, passband is narrower and insertion loss is larger. The difference of Insertion loss between Teflon and FR-4 increases with increasing measurement frequency.

  • PDF

The Design of Calculable Standard Dipole Antennas in the Frequency Range of 1~3 GHz

  • Kim, Ki-Chai;Kim, Sang-Myeong;Kwon, Jae-Yong;Kang, Tae-Weon;Kim, Jeong-Hwan
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.63-69
    • /
    • 2012
  • This paper presents the design of a calculable standard dipole antenna with a hybrid balun in the frequency range of 1 GHz to 3 GHz. A new formula of the antenna factor for a dipole antenna with a hybrid balun is derived using the power mismatch-loss concept. The antenna factors derived in this paper are in good agreement with the results calculated from S-parameters. The design results show that the calculable dipole antenna with a hybrid balun can be characterized by power mismatch-loss component factors.

Ni Loss During the Fabrication of SOFC Anode, Ni-YSZ Composite (SOFC 음극용 Ni-YSZ 복합체 제조시 생기는 Ni 손실)

  • Moon, Hwan;Lee, Jong-Ho;Lee, Hae-Weon
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.2
    • /
    • pp.137-142
    • /
    • 2001
  • SOFC 음극으로 쓰이는 Ni-YSZ 복합체의 제조과정 중에 생기는 조성의 변화를 관찰하였다. XRD를 이용하여 복합체 부위별로 상분석한 결과 Ni-YSZ 복합체는 소결과정이나 환원처리시 복합체 내-외부간의 조성차가 일어나며 이로 인해 전기적 물성의 불균일성이 나타난다. 복합체 조성의 불균일성 및 전기적 물성의 불균일성은 주로 복합체를 구성하는 Ni 성분의 변화에 기인했는데 소결과정이나 환원과정시 Ni 성분이 기판으로 확산해가거나 기상으로 증발해버려 Ni 손실이 생기기 때문인 것으로 나타났다. Ni 성분의 손실은 열처리 온도와 시간에 비례하여 커졌으며 이로 인해 복합체의 전기적 물성도 악화되었다.

  • PDF

Multi-physics Analysis for Temperature Rise Prediction of Power Transformer

  • Ahn, Hyun-Mo;Kim, Joong-Kyoung;Oh, Yeon-Ho;Song, Ki-Dong;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, a method for multi-physics analysis of the temperature-dependent properties of an oil-immersed transformer is discussed. To couple thermal fields with electromagnetic and fluid fields, an algorithm employing a user defined function (UDF) is proposed. Using electromagnetic analysis, electric power loss dependent on temperature rise is calculated; these are used as input data for multi-physics analysis in order to predict the temperature rise. A heat transfer coefficient is applied only at the outermost boundary between transformer and the atmosphere in order to reduce the analysis region. To verify the validity of the proposed method, the predicted temperature rises in high-voltage (HV) and low-voltage (LV) windings and radiators were compared with the experimental values.