• Title/Summary/Keyword: center in Seoul

Search Result 11,613, Processing Time 0.044 seconds

Analysis of Shadows Effect in Seoul Area for the Estimation of Roof-type PV Power Calculation (지붕형 태양광 발전량 산정을 위한 서울지역 그림자 효과 분석)

  • Yun, ChangYeol;Jung, BoRin;Kim, ShinYoung;Kim, ChangKi;Kim, JinYoung;Kim, HyunGoo;Kang, YongHeack;Kim, YongIl
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.45-53
    • /
    • 2018
  • For the preliminary step for estimating the performance of roof-type photovoltaic system in urban areas, we analyzed the solar radiation reduction ratio by shadow effect by buildings using DSM (Digital Surface Model) and GIS (Geographical Information System) tools. An average loss by the shadow is about 19% in Seoul. The result was related to the building density and distribution. Monthly results show that the winter season (December and January) was more affected by the shading than during the summer season (June and July). It is expected that useful empirical formulas can be made if more detailed correlation studies are performed.

GECKO Optical Follow-up Observation of Three Binary Black Hole Merger Events

  • Kim, Joonho;Im, Myungshin;Paek, Gregory S.H.;Lee, Chung-Uk;Kim, Seung-Lee;Chang, Seo-Won;Choi, Changsu;Hwang, Sungyong;Kang, Wonseok;Kim, Sophia;Kim, Taewoo;Lee, Hyung Mok;Lim, Gu;Seo, Jinguk;Sung, Hyun-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.53.3-54
    • /
    • 2021
  • We present optical follow-up observation results of three binary black hole merger (BBH) events, GW190408 181802, GW190412, and GW190503 185404, which were detected by the Advanced Ligo and Virgo gravitational wave (GW) detectors. Electromagnetic (EM) counterparts are generally not expected for BBH merger events, however, some theoretical models suggest that EM counterparts of BBH can possibly arise in special environments. To identify EM counterparts of the three BBH merger events, we observed high-credibility regions of the sky with telescopes of the Gravitational-wave EM Counterpart Korean Observatory (GECKO), including the Korea Microlensing Telescope Network (KMTNet). Our observation started as soon as 100 minutes after the GW event alert and covered roughly 29 - 63 deg2 for each event with a depth of 22.5 mag in R-band within hours of observation. No plausible EM counterparts were found for these events. Our result gives a great promise for the GECKO facilities to find EM counterparts within few hours from GW detection in future GW observation runs.

  • PDF

Evaluation of an Automated Liquid-Handling System with Fixed Pipetting Tips in Radioimmunoassay (고정용 팁을 사용하는 Automated Liquid-Handling System의 RIA적용의 평가)

  • Shin, Sun-Young;Kim, Hee-Sun;Lee, Hyun-Ju;Jang, Hyun-Young;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.190-196
    • /
    • 2010
  • Purpose: This study was undertaken to investigate the feasibility of using automated liquid-handling systems equipped with reusable fixed tips in Radioimmunoassays and to demonstrate that the use of an automated pipetting instrument can decrease in the typical daily workload. Materials and Methods: The precisions of the automated pipettor and the manual pipettor were determined gravimetrically (n=30). A total of 30 specimens for HBs Ag were repeatedly pipetted (three replicates) with the automated pipettor and then retested. PSA samples were simultaneously pipetted with either the automated pipettor or the manual pipettor and then analyzed (n=40). Sample carryover test assessed for CA19-9, AFP and HCG when the automated pipettor was used. Pipetting speed of the automated pipettor and the manual pipettor were compared by evaluation of each workload. Results: The precisions coefficients of variation (CV) were 2.1% for the automated pipettor and 1.6% for manual pipettor. The mean cpm and CV for each group of replicates were 41,203 cpm and 3.7% for HBs Ag positive specimens, and 99 cpm and 7.9% for HBs Ag negative specimens, respectively. PSA results showed no significant differences between automated pipettor and manual pipettor (p=0.15, r=0.999). Carryover for CA19-9, AFP and HCG analytes was <0.1 ppm or below the assay limit of detection. Pipetting speed was significantly improved by using the automated instrument. Conclusion: There was no evidence that the use of an automated pipettor adversely affected any of the performance characteristics of the assay. Indeed, routine use of the Tecan automated pipettor has resulted in a decrease in the typical daily workload.

  • PDF

Effect of Bifidobacteria on Production of Allergy-Related Cytokines from Mouse Spleen Cells

  • KIM HYE YOUNG;YANG JIN OH;JI GEUN EOG
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.265-268
    • /
    • 2005
  • To study the effect of bifidobacteria on preventing allergy response, levels of IFN-$\gamma$, IgG2a, IL-4, and IgG1 were investigated in splenocytes isolated from ovalbumin (OVA)­sensitized allergic mice and BGN4-administered allergy­suppressed mice in the presence of various bifidobacterial strains. Most of the bifidobacteria, except 2A, increased production of Th I-associated immune markers, IFN -$\gamma$ and IgG2a. In addition, most of the bifidobacteria, except 2A and 19A, decreased production of IL-4, whereas the differences in the production of IgG1 were less pronounced. These results suggest that some strains of bifidobacteria may have the potential to prevent the occurrence of allergy by switching Th1/Th2-type antibodies and/or related cytokines.

A Study of Skin Reflectance Using Kubelka-Munk Model (Kubelka-Munk 모델을 이용한 피부 분광반사율 연구)

  • Cho, A Ra;Kim, Su Ji;Lee, Jun Bae;Sim, Geon Young;Back, Min;Cho, Eun Seul;Jang, Ji Hui;Jang, Eunseon;Kim, Youn Joon;Yoo, Kweon Jong;Han, Jeong Woo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.1
    • /
    • pp.45-55
    • /
    • 2016
  • Light shows various optical behaviors such as reflection, absorption, and scattering on skin for individuals. In particular, reflection of light from the skin has been widely used as the brightness index of the skin of individuals through the measurement of the physical quantity of spectral reflectance. Therefore, the study of light behavior on skin would be useful for the preparation of new evaluation method in the development stage of make-up products. In this study, multi-dimensional analysis for spectral reflectance behavior of light on individual skin was performed using Kubelka-Munk model. Also, we analyzed the contribution of skin parameters such as skin thickness and hemoglobin, which could affect the spectral reflectance, using above model and literature information. Base on this, we calculated the theoretical reflectance of normal women for visual light, which showed good agreement with the measured reflectance. Our study of light propagation in skin based on Kubelka-Munk model provides useful insight for the development of personalized cosmetic in the near future.

Deep Learning-Based Algorithm for the Detection and Characterization of MRI Safety of Cardiac Implantable Electronic Devices on Chest Radiographs

  • Ue-Hwan Kim;Moon Young Kim;Eun-Ah Park;Whal Lee;Woo-Hyun Lim;Hack-Lyoung Kim;Sohee Oh;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1918-1928
    • /
    • 2021
  • Objective: With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. Materials and Methods: We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). Results: The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). Conclusion: The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.

Effects of Pronuclear Age in Freezing of Mouse Embryos on Survival and Development in Vitro after Cryopreservation (동결보존시 생쥐 전핵배아의 시기에 따른 생존율과 발생율의 비교)

  • Kim, H.S.;Ryu, B.Y.;Oh, S.K.;Suh, C.S.;Kim, S.H.;Choi, Y.M.;Kim, J.G.;Moon, S.Y.;Lee, J.Y.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.25 no.1
    • /
    • pp.59-64
    • /
    • 1998
  • This study was designed to evaluate the influence of pronuclear age on the survival and post-thawing development after cryopreservation of mouse embryos. Freezing and thawing were performed in the different pronuclear stages of mouse embryos after IVF. Embryos were obtained from $F_1$ hybrid mice and classified into 4 groups according to the pronuclear stage (6hr, 9hr, 12hr and 15hr after insemination). Pronuclear ova were slowly cooled in a biological freezer using 1.5M 1,2-propanediol and 0.1M sucrose as cryoprotectant. Thawing was done at room temperature and 1,2-propanediol was removed by multi-step dilutions. Both frozen-thawed embryos and control fresh embryos were cultured in vitro in Ham's F-10 medium supplemented with 4mg/ml BSA. In control group, the development rate after 48hr was 99.3%, and the complete hatching rate after 144hr was 61.3%. In experimental groups, the survival rate after thawing was 95.4% in 6hr, 88.7% in 9hr, 75.2% in 12hr and 62.4% in 15hr after insemination, the development rate after 48hr was 61.1, 77.0, 67.0 and 79.6%, respectively, and the complete hatching rate after 144hr was 25.7, 43.7, 42.2 and 60.0%, respectively. The survival rate in 15hr was significantly lower (p<0.05) compared with other groups. In vitro development rates after 48hr were similar in all groups, but complement hatching rate was significantly lower (p<0.05) in 6hr group. In conclusion, cryopreservation of mouse pronuclear ova with 2 distinct pronuclei (9hr and 12hr groups) showed better results after thawing compared with early (6hr group) or late pronuclear ova just prior to cleavage (15hr group).

  • PDF

Which Index for Muscle Mass Represents an Aging Process?

  • Kim, Hyung-Kook;Lee, You Jin;Lee, Young-Kyun;Kim, Hongji;Koo, Kyung-Hoi
    • Journal of Bone Metabolism
    • /
    • v.25 no.4
    • /
    • pp.219-226
    • /
    • 2018
  • Background: Although studies and interest in sarcopenia have increased, it is still a matter of debate which muscle mass index better represents the aging process. We compared 3 indices for muscle mass (appendicular skeletal muscle mass [ASM]/weight, $ASM/height^2$, and the body mass index [BMI]-adjusted muscle mass index [ASM/BMI]) to determine which better reflected the aging process in terms of the decline in bone mineral density (BMD), visual acuity (VA), hearing power, renal function, pulmonary function, and handgrip strength. Methods: We performed a retrospective cross-sectional study using the Korea National Health and Nutrition Examination Survey in the Korean population. Between 2008 and 2011, a total of 14,415 men and 17,971 women aged 10 years or older participated in the study. We plotted the changes in the 3 indices of muscle mass and compared these with changes in BMD, VA, hearing power, renal function, pulmonary function, and handgrip strength according to each age group. Results: The ASM/BMI showed similar changes in terms of surrogate markers of the aging process, while the ASM/weight and $ASM/height^2$ showed no correlation. Conclusions: Among muscle indices for sarcopenia, only the ASM/BMI represented the aging process.

Fluorescent Blue Materials for Efficient Organic Light-Emitting Diode with High Color Purity

  • Choi, Kyung-Sun;Lee, Chan-Hyo;Lee, Kwan-Hee;Park, Su-Jin;Son, Seung-Uk;Chung, Young-Keun;Hong, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1549-1552
    • /
    • 2006
  • We report a new series of blue dopants composed of both electron donating and electron accepting moieties in one molecule, based on nalidixic acid. The EL device derived from the dopant exhibits pure blue light emission (0.15, 0.14) The current efficiency is estimated to be 3.88 cd/A at 100 $cd/m^2$, which shows remarkable enhancement, compared to that of the host itself (2.5 cd/A at 100 $cd/m^2$) under the same conditions. These results demonstrate that the incorporation of a proper guest into the host in a guest-host doped system improves not only the purity of the fluorescent blue emission but also elevates its quantum efficiency, thus improving the OLED performance.

Effect of various MgO E-beam evaporation sources on the characteristics of MgO protecting layer of AC-PDP

  • Park, Sun-Young;Lee, Mi-Jung;Kim, Soo-Gil;Kim, Hyeong-Joon;Moon, Sung-Hwan;Kim, Jong-Kuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.223-226
    • /
    • 2004
  • MgO thin films were deposited bye-beam evaporation on $SiO_2$/Si wafers for the application of a protective layer in alternating current plasma display panels (AC-PDPs). Three different MgO sources, single crystal, melted polycrystal and sintered polycrystal, were used to find out the change of the properties of MgO protective layer depending on the source type. The properties of MgO thin films such as density, orientation and surface morphology were influenced by the source type. MgO thin films deposited with the melted polycrystal source had the highest density with the highest (100) preferred orientation, whereas the films deposited with the sintered polycrystal source had the lowest density with less preferred orientation. Such a result seems to be originated from the different mobility of adatoms on the surface of the deposited MgO thin films. Different microstructures of MgO thin films deposited even in the same deposition condition were observed depending on the MgO source type, resulting in different discharge characteristics.

  • PDF