• Title/Summary/Keyword: center detection

Search Result 3,708, Processing Time 0.038 seconds

Cloudy Area Detection Algorithm By GHA and SOFM

  • Seo, Seok-Bae;Kim, Jong-Woo;Lee, Joo-Hee;Lim, Hyun-Su;Choi, Gi-Hyuk;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.458-460
    • /
    • 2003
  • This paper proposes new algorithms for cloudy area detection by GHA (Generalized Hebbian Algorithm) and SOFM (Self-Organized Feature Map). SOFM and GHA are unsupervised neural networks and are used for pattern classification and shape detection of satellite image. Proposed algorithm is based on block based image processing that size is 16${\times}$16. Results of proposed algorithm shows good performance of cloudy area detection except blur cloudy area.

  • PDF

Extension of Range Migration Algorithm for Airborne SAR Data Processing

  • Shin, Hee-Sub;Song, Won-Gyu;Son, Jun-Won;Jung, Yong-Hwan;Lim, Jong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.857-860
    • /
    • 2005
  • Several algorithms have been developed for the data processing of spotlight synthetic aperture radar (SAR). In particular, the range migration algorithm (RMA) does not assume that illuminating wavefronts are planar. Also, a high resolution image can be obtained by the RMA. This paper introduces an extension of the original RMA to enable a more efficient airborne SAR data processing. We consider more general motion and scene than the original RMA. The presented formulation is analyzed by using the principle of the stationary phase. Finally, the extended algorithm is tested with numerical simulations using the pulsed spotlight SAR.

  • PDF

Fast Center Lane Detection Method for Vehicle Applications (차량 탑재를 위한 고속 중앙차선 인식 방법)

  • Jang, Kwang-Hee;Kwak, Seong-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.6
    • /
    • pp.649-656
    • /
    • 2014
  • In this paper, we address the problem of center lane detection algorithm for autonomous driving. Color information for center lane is gathered by analyzing a row line color distribution of road in front of a vehicle. The candidate pixels for center lane are extracted from the histogram of road colors. Morphological filtering and clustering process are applied to the candidate pixels to extract the exact center lane. We predict a expected area of center lane and search only the regions in subsequent frames, that reduces the time required for center lane detection.

Initial experience of magnetic resonance imaging/ultrasonography fusion transperineal biopsy: Biopsy techniques and results for 75 patients

  • Tae, Jong Hyun;Shim, Ji Sung;Jin, Hyun Jung;Yoon, Sung Goo;No, Tae Il;Kim, Jae Yoon;Kang, Seok Ho;Cheon, Jun;Kang, Sung Gu
    • Investigative and Clinical Urology
    • /
    • v.59 no.6
    • /
    • pp.363-370
    • /
    • 2018
  • Purpose: The aim of this study is to describe the technique and to report early results of transperineal magnetic resonance imaging and ultrasonography (MRI-US) fusion biopsy. Materials and Methods: A total of 75 patients underwent MRI-US fusion transperineal biopsy. Targeted biopsy via MRI-US fusion imaging was carried out for cancer-suspicious lesions with additional systematic biopsy. Detection rates for overall and clinically significant prostate cancer (csPCa) were evaluated and compared between systematic and targeted biopsy. In addition, further investigation into the detection rate according to prostate imaging reporting and data system (PI-RADS) score was done. Results of repeat biopsies were also evaluated. Results: Overall cancer detection rate was 61.3% (46 patients) and the detection rate for csPCa was 42.7% (32 patients). Overall detection rates for systematic and targeted biopsy were 41.3% and 57.3% (p<0.05), respectively. Detection rates for csPCa were 26.7% and 41.3%, respectively (p<0.05). The cancer detection rates via MRI fusion target biopsy were 30.8% in PI-RADS 3, 62.1% in PI-RADS 4 and 89.4% in PI-RADS 5. Rates of csPCa missed by targeted biopsy and systematic biopsy were 0.0% and 25.0%, respectively. The cancer detection rate in repeat biopsies was 61.1% (11 among 18 patients) in which 55.5% of cancer suspected lesions were located in the anterior portion. Conclusions: Transperineal MRI-US fusion biopsy is useful for improving overall cancer detection rate and especially detection of csPCa. Transperineal MRI-US targeted biopsy show potential benefits to improve cancer detection rate in patients with high PIRADS score, tumor located at the anterior portion and in repeat biopsies.

Improvement of a Detecting Algorithm for Geometric Center of Typhoon using Weather Radar Data (레이더 자료를 이용한 기하학적 태풍중심 탐지 기법 개선)

  • Jung, Woomi;Suk, Mi-Kyung;Choi, Youn;Kim, Kwang-Ho
    • Atmosphere
    • /
    • v.30 no.4
    • /
    • pp.347-360
    • /
    • 2020
  • The automatic algorithm optimized for the Korean Peninsula was developed to detect and track the center of typhoon based on a geometrical method using high-resolution retrieved WISSDOM (WInd Syntheses System using DOppler Measurements) wind and reflectivity data. This algorithm analyzes the center of typhoon by detecting the geometric circular structure of the typhoon's eye in radar reflectivity and vorticity 2D field data. For optimizing the algorithm, the main factors of the algorithm were selected and the optimal thresholds were determined through sensitivity experiments for each factor. The center of typhoon was detected for 5 typhoon cases that approached or landed on Korean Peninsula. The performance was verified by comparing and analyzing from the best track of Korea Meteorological Administration (KMA). The detection rate for vorticity use was 15% higher on average than that for reflectivity use. The detection rate for vorticity use was up to 90% for DIANMU case in 2010. The difference between the detected locations and best tracks of KMA was 0.2° on average when using reflectivity and vorticity. After the optimization, the detection rate was improved overall, especially the detection rate more increased when using reflectivity than using vorticity. And the difference of location was reduced to 0.18° on average, increasing the accuracy.

Urinary Biomarkers for the Noninvasive Detection of Gastric Cancer

  • Li, Dehong;Yan, Li;Lin, Fugui;Yuan, Xiumei;Yang, Xingwen;Yang, Xiaoyan;Wei, Lianhua;Yang, Yang;Lu, Yan
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.306-318
    • /
    • 2022
  • Gastric cancer (GC) is associated with high morbidity and mortality rates. Thus, early diagnosis is important to improve disease prognosis. Endoscopic assessment represents the most reliable imaging method for GC diagnosis; however, it is semi-invasive and costly and heavily depends on the skills of the endoscopist, which limit its clinical applicability. Therefore, the search for new sensitive biomarkers for the early detection of GC using noninvasive sampling collection methods has attracted much attention among scientists. Urine is considered an ideal biofluid, as it is readily accessible, less complex, and relatively stable than plasma and serum. Over the years, substantial progress has been made in screening for potential urinary biomarkers for GC. This review explores the possible applications and limitations of urinary biomarkers in GC detection and diagnosis.

Efficiency calculation of the nMCP with 10B doping based on mathematical models

  • Yang, Jianqing;Zhou, Jianrong;Zhang, Lianjun;Tan, Jinhao;Jiang, Xingfen;Zhou, Jianjin;Zhou, Xiaojuan;Hou, Linjun;Song, Yushou;Sun, XinLi;Zhang, Quanhu;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2364-2370
    • /
    • 2021
  • The nMCP (Neutron sensitive microchannel plate) combined with advanced readout electronics is widely used in energy selective neutron imaging because of its good spatial and timing resolution. Neutron detection efficiency is a crucial parameter for the nMCP. In this paper, a mathematical model based on the oblique cylindrical channel and elliptical pore was established to calculate the neutron absorption probability, the escape probability of charged particles and overall detection efficiency of nMCP and analyze the effects of neutron incident position, pore diameter, wall thickness and bias angle. It was shown that when the doping concentration of the nMCP was 10 mol%, the thickness of nMCP was 0.6 mm, the detection efficiency could reach maximum value, about 24% for thermal neutrons if the pore diameter was 6 ㎛, the wall thickness was 2 ㎛ and the bias angle was 3 or 6°. The calculated results are of great significance for evaluating the detection efficiency of the nMCP. In a subsequent companion paper, the mathematical model would be extended to the case of the spatial resolution and detection efficiency optimization of the coating nMCP.

Development of a Multiplex RT-PCR for the Simultaneous Detection of Three Viruses in Cherry Plants

  • Park, Chung Youl;Park, Jeongran;Lee, Geunsik;Yi, Seung-In;Kim, Byeong Hoon;Eom, Jung Sik;Lee, Som Gyeol;Kim, Hongsup
    • Research in Plant Disease
    • /
    • v.24 no.3
    • /
    • pp.233-236
    • /
    • 2018
  • A multiplex RT-PCR (mRT-PCR) assay was developed for the detection of the recently reported viruses, Cherry virus A (CVA), Little cherry virus 1 (LChV-1), and Little cherry virus 2 (LChV-2), in cherry plants in Korea. Eight sets of primers were designed for each virus and their specificity was tested by using various combinations of mixed primer sets. From the designed primer sets, one combination was selected and further evaluated to estimate the optimum temperature and detection limits of the mRT-PCR. A newly developed mRT-PCR assay was also tested using 20 cherry samples collected in the field. This mRT-PCR assay may be a useful tool for field surveys of diseases and the rapid detection of these three viruses in cherry plants.

A Study on Design and Analysis of an Alert-Confirm Detection Method (Alert-Confirm 탐지 방식의 설계 및 성능 분석에 관한 연구)

  • Eunhee Kim;Hyunsu Oh;Sawon Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.140-146
    • /
    • 2024
  • Active electronically scanning antennas are faster and more flexible in beam-scheduling than mechanical antennas. Thus, they require an advanced resource management or detection methods to operate efficiently. In a surveillance radar performing periodic detection, alert-confirm detection is an excellent method to improve the cumulative detection probability by reducing the period while maintaining the detection probability. This paper proposes a design method for alert-confirm detection based on the parameters of the conventional design. We developed a simulator based on simulink@matworks and verified the result through Monte Carlo simulation.

Effect of Applied Voltage on the Reliability of Coating Flaw Detection of Pipe with Different Buried Depths

  • Lim, B.T.;Kim, M.G.;Kim, K.T.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.277-284
    • /
    • 2019
  • External corrosion control of buried pipe can be achieved by the combination of barrier coating and cathodic protection. Coating damage and deterioration can be induced by many reasons; damage during handling and laying, enhanced failure at low temperatures, failure during commissioning and operation, disbanding due to inadequate surface cleaning, rock penetration during installation and service etc. This work focused on the effect of survey conditions on the reliability of coating flaw detection of buried pipes. The effects of applied voltage and anode location on the detection reliability of coating flaw of buried pipe in soil with the resistivity of ca. 25.8 kΩ·cm were discussed. Higher applied voltage increased the detection reliability, regardless of buried depth, but deeper burial depth reduced the reliability. The location of the anode has influenced on the detection reliability. This behaviour may be induced by the variation of current distribution by the applied voltage and buried depth. From the relationship between the applied voltage and reliability, the needed detection potential to get a desire detection reliability can be calculated to get 100% detection reliability using the derived equation.