• 제목/요약/키워드: cell controller

검색결과 371건 처리시간 0.031초

MPPT Control and Architecture for PV Solar Panel with Sub-Module Integrated Converters

  • Abu Qahouq, Jaber A.;Jiang, Yuncong;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1281-1292
    • /
    • 2014
  • Photovoltaic (PV) solar systems with series-connected module integrated converters (MICs) are receiving increased attention because of their ability to create high output voltage while performing local maximum power point tracking (MPPT) control for individual solar panels, which is a solution for partial shading effects in PV systems at panel level. To eliminate the partial shading effects in PV system more effectively, sub-MICs are utilized at the cell level or grouped cell level within a PV solar panel. This study presents the results of a series-output-connection MPPT (SOC-MPPT) controller for sub-MIC architecture using a single sensor at the output and a single digital MPPT controller (sub-MIC SOC-MPPT controller and architecture). The sub-MIC SOC-MPPT controller and architecture are investigated based on boost type sub-MICs. Experimental results under steady-state and transient conditions are presented to verify the performance of the controller and the effectiveness of the architecture.

유연생산시스템의 계층구조적 실시간 운용제어 및 모니터링에 관한 연구 (A Study on the Hierarchical Real-time Operation Control and Monitoring for an Flexible Manufacturing System)

  • 김종원
    • 한국정밀공학회지
    • /
    • 제9권4호
    • /
    • pp.36-43
    • /
    • 1992
  • This paper presents a hierarchical real-time operation control and monitoring scheme of the FMS/CIM center which has been implemented at the Automation and Systems Research Institute of Seoul National University. The hierarchical structure of the whole scheme consists of three lavers. The upper layer is in charge of on-line scheduling, computer network control, shop-floor monitoring and command generation for AGV dispatching, machining, assembly, inspection, set-up, etc. The middle layer has six modules, which are installed in the FMS host computer with the upper layer and run on the multi-tasking basis. Each module is connected to one of six cell controllers distributed in the FMS model plant and transfers operation command down to each cell controller through the Ethernet/TCP-IP local area network. The lower layer is comprised of six cell control software modules for machining cell, assembly cell, inspection cell, set-up stations. AS/RS and AGV. Each cell controller reports the status of the manufacturing facilites to the middle layer as well as ecxecuting the appropriate sequence control of the manufacturing processes.

  • PDF

자동화 시스템내 셀 제어기의 통신 소프트웨어 개발 및 실험 (Communication Software Development and Experiments for a Cell Controller in a CIM System)

  • S.H. Do;B.S. Jung;Park, G.J.
    • 한국정밀공학회지
    • /
    • 제12권4호
    • /
    • pp.88-99
    • /
    • 1995
  • The demand for automatic manufacturing systems is increasing. Flexible Manufacturing System(FMS) is usually considered as a soluting for the shop floor automation. One of the difficulties in FMS is the communications problem. Since various machineries with different communications protocoles are included, applying a unified scheme is almost impossible. Therefore, a systematic approach is a key point to solve the communication problem. A cell is difined as an automation unit where closely related for a job reside together. A cell is a messenger between upper level computers and lower level machine equipment. In this research, the fonctions of the cell are defined to have more capabilities than conventional cells since a cell can be often a total manufacturing system is a small to medium sized factory. The cell conducts communications with different machines through the communications schemes established here. A set of software system has been developed according to the defined communication. The software has been tested for a simulation and real experiments for proof.

  • PDF

MPLS모듈과 ATM모듈과의 Cell Mode 인터페이스를 위한 Multi-Port지원 UTOPIA-L2 Controller구현 (The Implementation of Multi-Port UTOPIA Level2 Controller for Interworking ATM Interface Module and MPLS Interface Module)

  • 김광옥;최병철;박완기
    • 한국통신학회논문지
    • /
    • 제27권11C호
    • /
    • pp.1164-1170
    • /
    • 2002
  • ACE2000 MPLS시스템에서 MPLS 정합모듈은 ATM 정합모듈과 패킷 포워딩을 수행하는 HFMA(High performance Forwarding Engine and VC Merging board Assembly)모듈로 구성된다. MPLS 정합모듈에서 물리층으로 입력되는 셀은 HFMA의 송신 SAR칩(RSAR)에서 패킷으로 조립된 후 IP룩업 제어기에서 패킷 포워딩을 수행한다. 포워딩된 패킷은 ATM 계층으로 전달되기 위해 수신 SAR칩(TSAR)에서 셀로 다시 세그먼트된 후 ATM 셀 스위치로 전송하기 위해 ALMA(ATM Layer Module Assembly)로 전달된다. MPLS 정합모듈을 ATM 정합보듈로 이용할 때, ALMA는 직접 물리층 보드와 UTOPIA Leve12 인터페이스로 연결되며, 이때 ALMA는 Master Mode로 동작하게 된다 또한 MPLS 정합모듈에서 HFMA TSAR도 Master Mode로 동작하게 된다. 따라서 2개의 Master 모드 사이에서 인터페이스 역할을 수행할 수 있는 Slave 모드의 UTOPIA-L2 Controller가 요구된다. 본 논문에서는 Multi-Ports를 지원할 수 있는 UTOPIA-L2 Controller의 구조 및 셀 제어방법에 대해 고찰해본다.

Design and Research on High-Reliability HPEBB Used in Cascaded DSTATCOM

  • Yang, Kun;Wang, Yue;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.830-840
    • /
    • 2015
  • The H-bridge inverter is the fundamental power cell of the cascaded distribution static synchronous compensator (DSTATCOM). Thus, cell reliability is important to the compensation performance and stability of the overall system. The concept of the power electronics building block (PEBB) is an ideal solution for the power cell design. In this paper, an H-bridge inverter-based “plug and play” HPEBB is introduced into the main circuit and the controller to improve the compensation performance and reliability of the device. The section that discusses the main circuit primarily emphasizes the design of electrical parameters, physical structure, and thermal dissipation. The section that presents the controller part focuses on the principle of complex programmable logic device -based universal controller This section also analyzes typical reliability and anti-interference issues. The function and reliability of HPEBB are verified by experiments that are conducted on an HPEBB test-bed and on a 10 kV/± 10 Mvar DSTATCOM industrial prototype.

고휘도 LED를 이용한 세포배양 컨트롤러에 관한 연구 (A Study on the Cell Culture Controller using the High Brightness LED)

  • 천민우;김성환;송창훈;문성표;김태곤;박용필;김대영;김영수
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1149-1153
    • /
    • 2006
  • We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage.

Solar Cell을 적용한 교통 시설물용 휀스의 전원 충전용 컨트롤러에 관한 연구 (The Study on the Controller for Battery of fence power supply with traffic Auxiliary system by Solar Cell)

  • 윤형상;임중열;윤석암;차인수;장헌
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.166-169
    • /
    • 1998
  • This paper represent about design of the controller for battery of fence with traffic controller for battery of fence with traffic auxiliary system for power supply using solar cell. Simulation is represents V-I and power characteristic by Pspice. This system is successfully operating with high clearness lights.

  • PDF

New GGNMOS I/O Cell Array for Improved Electrical Overstress Robustness

  • Pang, Yon-Sup;Kim, Youngju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권1호
    • /
    • pp.65-70
    • /
    • 2013
  • A 0.18-${\mu}m$ 3.3 V grounded-gate NMOS (GGNMOS) I/O cell array for timing controller (TCON) application is proposed for improving electrical overstress (EOS) robustness. The improved cell array consists of 20 GGNMOS, 4 inserted well taps, 2 end-well taps and shallow trench isolation (STI). Technology computer-aided design (TCAD) simulation results show that the inserted well taps and extended drain contact gate spacing (DCGS) is effective in preventing EOS failure, e.g. local burnout. Thermodynamic models for device simulation enable us to obtain lattice temperature distributions inside the cells. The peak value of the maximum lattice temperature in the improved GGNMOS cell array is lower than that in a conventional GGNMOS cell array. The inserted well taps also improve the uniformity of turn-on of GGNMOS cells. EOS test results show the validity of the simulation results on improvement of EOS robustness of the new GGNMOS I/O cell array.

낮은 출력 리플을 갖는 연료전지를 이용한 리튬폴리머 전지용 비절연형 승압 충전기의 설계 (Design of the Non-Isolated Fuel Cell Boost Charger for the Lithium Polymer Battery with Low Output Ripple)

  • 트란반롱;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.182-183
    • /
    • 2013
  • In the design of the fuel cell charger, it is important to find out the suitable topology and to design the converter to guarantee the performance of the fuel cell as well as the battery. Most of the chargers developed so far have used step-down converters. However, since the small fuel cell stack can only generate a low voltage, it is required to use the step-up converter to charge the battery. In this paper, a modified non-isolated boost charger topology for the Proton Exchange Membrane Fuel Cell (PEMFC) is proposed to meet the strict ripple requirements for the battery charge and its control method by using PI controller is detailed. The feasibility of the proposed topology and its control method is then verified by the experiments.

  • PDF